Benewake TF02-Pro-W-485 Obstacle Detection LIDAR Sensor
PREFACE
Dear users:
Thank you for choosing Benewake products. In the purpose of offering better operation experience to you, we hereby write this manual for an easier and simpler operation of our product, hoping to better solve the common problems you may meet.
This user manual contains relevant information on product introduction, usage and maintenance of TF02-Pro-W-485, covers the product operation introduction and common problem solutions. Please read this manual carefully before using the product. Remember the precautions to avoid hazards, and please follow the described steps in the manual when using it. If you have any problems in the process of using, you are welcome to contact Benewake at any time for help.
Contact details
Official website: en.benewake.com
TEL: +86-10- 57456983
Technical questions, please contact: support@benewake.com
Consult sale information or request brochure, please contact: bw@benewake.com
Headquarters Address
Benewake (Beijing) Co., Ltd.
No.3030, 3rd Floor, Independent Innovation Building, No.6 Chuangye Road, Haidian District, Beijing, China
Copyright Statement
This User Manual is copyright © of Benewake. Please do not modify, delete or translate the description of this manual contents without the official written permission from Benewake.
Disclaimer
As our products are constantly improving and updating, the specifications of TF02-Pro-W-485 are subject to change. Please refer to the official website for latest version.
OVERVIEW
TF02-Pro-W-485 is a single-point ranging LiDAR based on upgraded TF02-Pro-W using ToF (Time of Flight) principle. It has been optimized in communication interface, input voltage and reverse voltage protection, adapted to the needs of industrial scenarios.
Technical Specification
Table 1-1 Technical specification of TF02-Pro-W-485
Type | Parameters | Value | |
Product performance | Operating range | 90% reflectivity, 0Klux | 0.1m~25m |
10% reflectivity, 0Klux | 0.1m~12m | ||
90% reflectivity, 100Klux | 0.1m~25m | ||
10% reflectivity, 100Klux | 0.1m~12m | ||
Accuracy① | ±6cm(0.1m~6m),
±1%(6m~25m) |
||
Distance resolution① | 1cm | ||
Frame rate② | 1Hz~1000Hz
( adjustable, default 100Hz) |
||
Repeatability① | 1σ: <2cm
(0.1m~25m@90% reflectivity ) |
||
Ambient light immunity | 100Klux | ||
Enclosure rating | IP5X | ||
Optical parameters | Photobiological safety | Class1 (IEC60825) | |
Central wavelength | 850nm | ||
Light source | VCSEL | ||
FoV③ | 3° | ||
Electrical parameters | Supply voltage | DC 7V~30V | |
Average current | ≤200mA@12V | ||
Power consumption | ≤4.8W | ||
Peak current | 400mA@12V | ||
Others | Dimension | 85mm×59mm×43mm (L×H×W) | |
Housing | PC/ABS | ||
Operating temperature | -20℃~60℃ | ||
Storage temperature | -30℃~80℃ | ||
Weight | 92g (with cables) |
Cable length | 120cm |
Note
- The detection range is measured with the standard white board (90%reflectivity).
- The frame rate can be adjusted. The default value is 100Hz and the maximum value is 1000Hz, customized frame rate should be calculated by the formula: 2000/n (n is an integer with ≥ 2).
- The angle is a theoretical value, the actual angle value has some deviation.
Maintenance and Cleaning
- Before switching on, please check if the exposed window mirror is clean, and clean it promptly if it is dirty.
- After using the device, check the optics. If they are contaminated, please clean it promptly.
- The optics should be cleaned regularly if the device be operated in a severe environment for a long time.
- Before regular cleaning, please disconnect the power. Using a soft cloth to gently wipe the window in the same direction when the device is not operating, to avoid repeated wiping and damage to the window mirror.
- Do not remove the dust-removal wiper, which may cause equipment failure. If the dust-removal wiper is abnormal, please contact bw@benewake.com.
- When the steering shaft is blocked by dust for a long time, the steering shaft may be damaged due to the increased resistance. Please clean the steering shaft regularly.
- If you require deep cleaning of internal optics, please contact bw@benewake.com to offer professional advice.
Appearance and Structure
The appearance and dimensions of TF02-Pro-W-485 are shown in Figure 1-1 and Figure 1-2.
TF02-Pro-W-485 is recommended to use M2.5 round Phillips screws for installation. Please remove the protective film of the optical lens before use. The lens of front panel of LiDAR cannot be covered. Please keep it clean. The surface of optical lens is the ranging zero of LiDAR. The detection angle of TF02-Pro-W-485 is 3°. At different distances, the size of light spot, namely the edge length of the detection range, is different, as shown in Figure 1-3. Side length of the detection range at different distances (the detection range is a square), as shown in Table 1-2.
Table 1-2 Spot Size at Different Distances
Distance(m) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 15 | 20 | 22 |
Spot size(cm) | 5 | 10 | 16 | 21 | 26 | 31 | 37 | 42 | 47 | 52 | 79 | 105 | 115 |
Note: The side length of target object generally should be larger than size of the TF02-Pro-W-485 light spot; if the side length of the detected object is smaller than size of light spot, the output (Distance) from TF02-Pro-W-485 will be a value between the actual distance values of the two objects.
Storage
- Device should be stored at -30°C to 80°C with a relative humidity ≤ 60% and ventilation free from corrosive gases.
- Before storage, please make sure that all connections are disconnected or dust covers are inserted or covered to ensure cleanliness.
- If storage time is over three months, please carry out a working test before using, to ensure that the device can be used in normal condition.
- For ensuring the product performance, do not open the product shell or remove the IR-pass filter.
INTERFACE
Description About Wiring Sequence
The external tail cable of TF02-Pro-W-485 has no connector by default, the wiring sequence is shown in Table 2-1.
Table 2-1 The function description of each wire
Wiring color | Function | Comment |
Red | VCC | Power supply |
Black | GND | Ground |
White | RS-485-B | DATA- |
Green | RS-485-A | DATA+ |
Electrical Characteristics
TF02-Pro-W-485 has overvoltage and reverse polarity protection, but do not connect to power rails higher than 36V, reverse polarity protection voltage is -30V. The electrical characteristics are shown in Table 2-2.
Table 2-2 Main electrical parameters of TF02-Pro-W-485
Parameter | Value |
Supply voltage | DC 7V~30V |
Average current | ≤200mA@12V |
Peak current | 400mA@12V |
Average power consumption | ≤4.8W |
Communication level | RS-485 |
WIPER WORKING
The dust-removal wiper works in a fixed cycle, having a dust-removal operation every 4 hours in the default working mode. Each dust-removal operation is driven by the LiDAR servo, the wiper moves backwards and forwards for one time. And TF02-Pro-W-485 will also perform dust-removal operation once after each power-on. In addition, customer can control the LiDAR immediately by sending command for dust-removal, and modify the wiper swing times and save the settings. During the dust removal operation, the LiDAR does not measure and output data. The wiper stops at position A when it does not work, and moves from position A to position B during operation, then returns to position A, the initial and termination positions are shown in Figure 3-1.
Note: It is recommended that the dust-removal interval should be kept greater than 30 minutes, when servo is in high-temperature environments (ambient temperature > 40 ℃).
COMMUNICATION PROTOCOL
RS-485 Communication Interface
TF02-Pro-W-485 uses RS-485 communication standard with 2-wire interface, the communication protocol parameters are shown in Table 4-1. The default baud rate is 115200, the default slave ID is 0x01.
Table 4-1 TF02-Pro-W-485 RS-485 communication protocol
Communication interface | RS-485 |
Default baud rate | 115200 |
Data bit | 8 |
Stop bit | 1 |
Parity check | None |
Warning
TF02-Pro-W-485 supports 9600, 14400, 19200, 38400, 43000, 57600, 76800, 115200 (default), 128000, 230400, 256000, 460800, 921600, 1382400 baud rates. It is not recommended to use the baud rate above 115200.
Modbus Protocol
- Description about frame format
When TF02-Pro-W-485 Modbus protocol is enabled, the Modbus reading distance command format is shown in Table 4-2.
Table 4-2 The Modbus reading distance command formatAddress field Function code Register address Register number CRC_Low CRC_High 01 03 00 00 00 01 xx xx The data frame returned by TF02-Pro-W-485 is as follows:
Table 4-3 The data frame formatAddress field Function code Data length Dist_High Dist_Low CRC_Low CRC_High 01 03 02 XX XX xx xx - Function Code
The function code of TF02-Pro-W-485 is shown in Table 4-4.
Table 4-4 The function code of TF02-Pro-W-485Function code Description 03 Read register 06 Write register - Register Address
- All register addresses are hexadecimal and register values are 16 bits;
- After setting parameter, save settings and restart LiDAR to take effect.
- Register Address for Reading Function Code
Table 4-5 Register address list using function code: 0x03(read-only)Register address Definition Description 00 00 Dist Distance, unit: cm 00 01 Strength Signal strength 00 03 High 16bit of timestamp 2 high-order bits of timestamp represent relative time of LiDAR start up, unit: ms 00 04 Low 16bit of timestamp 2 low-order bits of timestamp represent relative time of LiDAR start up, unit: ms 00 06 High 16bit of software version 00 + major version number 00 07 Low 16bit of software version Minor version number + revised version number - Register Address for Writing Function Code
Table 4-6 Register address list using function code: 0x06(write only)Register address Definition Description 00 80 Save settings Write any value to save settings 00 81 Power off/restart Register value:0-Power off (unavailable currently); 1-Restart 00 82 Disable Modbus Register value:1-Disable Modbus; Others-Error reply 00 83 Baud rate High Set baud rate. Restart to take effect 00 84 Baud rate Low Set baud rate. Restart to take effect 00 85 Slave ID Set slave ID. Restart to take effect (default 0x01) 00 86 FPS Set frame rate. Restart to take effect (default 100Hz) 00 87 Working mode Set working mode. Restart to take effect after saving settings. Register value: 0- Continuously detection mode(default) 1-Trigger mode Others-Error reply
00 88 Low-power consumption mode Set low-power consumption mode,Restart to take effect after saving settings. Register value: 0-Disable(default)
>0 and≤10-Enable (the value is inside sampling frequency.)
00 89 Restore defaults Write any value. Restart to take effect after saving settings. 00 8A Start the wiper Write any value. Start the wiper at any time. 00 8C Modify dust removal cycle Unit: minutes (default 240 minutes). Take effect immediately. 00 8D Modify number of wiper swings The number should between 1 and 10 (default once). Take effect immediately.
- Register Address for Reading Function Code
Parameter Configuration
- Table 4-7 TF02-Pro-W-485 general parameter configuration under serial link mode
Function Command Response Description Enable Modbus 5A 05 15 01 75 5A 05 15 01 75 Save settings and restart to take effect. Save setting 5A 04 11 6F 5A 05 11 00 70 - Table 4-8 TF02-Pro-W-485 general parameter configuration with Modbus instructions
Function Command Response Description Read distance 01 03 00 00 00 01 84 0A
01 03 02 DH DL CL CH DH: 8 high-order bits of distance DL: 8 low-order bits of distance CL: 8 low-order bits of CRC CH: 8 high-order bits of CRC
Read distance and strength 01 03 00 00 00 02 C4 0B
01 03 04 DH DL SH SL CL CH DH: 8 high-order bits of distance DL: 8 low-order bits of distance SH: 8 high-order bits of signal strength
SL: 8 low-order bits of signal strength CL: 8 low-order bits of CRC CH: 8 high-order bits of CRC
Read firmware version 01 03 00 06 00 02 24 0A
01 03 04 00 VM VS VC CL
CH
The software version is VM.VS.VC Set baud rate 01 06 00 83 BH1 BH2 CL CH
01 06 00 84
BL1 BL2 CL CH
01 06 00 83 BH1 BH2 CL CH
01 06 00 84
BL1 BL2 CL CH
BH1, BH2, BL1, BL2 are high, secondary high, secondary low and low bytes of baud rate. E.g., set baud rate to 9600 (0x00002580) BH1=00 BH2=00 CL=78 CH=22
BL1=25 BL2=80 CL=D2 CH=D3
Set slave ID 01 06 00 85 IH IL CL CH 01 06 00 85 IH IL CL CH IH, IL are high and low bytes of ID. For example, set ID to 2,IH=00 IL=02 CL=19 CH=E2 Set frame rate 01 06 00 86 FH FL CL CH 01 06 00 86 FH FL CL CH FH, FL are high and low bytes of frame rate. E.g., Set frame rate to 100 (0x0064), FH=00 FL=64 CL=69 CH=C8
Set low- power consumption mode 01 06 00 88 LH LL CL CH 01 06 00 88 LH LL CL CH LH, LL are high and low bytes of low power sampling rate. For example, set it to 5HZ low-power consumption mode, LH=00 LL=05 CL=C9 CH=E3
Save settings 01 06 00 80 00 00 88 22
01 06 00 80 00 00 88 22
Save settings and restart LiDAR to take effect Disable Modbus
01 06 00 82 00 01 E8 22
01 06 00 82 00 01 E8 22
Save settings and restart LiDAR to take effect Start the wiper
01 06 00 8A 00 00 A8 20
01 06 00 8A 00 00 A8 20
Start the wiper at any time Modify dust removal cycle 01 06 00 8C PH PL CL CH 01 06 00 8C PH PL CL CH PH, PL are high and low bytes of cycle. E.g., making wiper works every 240 minutes (0x00F0), PH=00 PL=F0 CL=48 CH=65 Modify the number of wiper round trips 01 06 00 8D WH WL CL CH 01 06 00 8D WH WL CL CH WH, WL are high and low bytes of number of round trips. The number should between 1 and 10. E.g., twice each time WH=00 WL=02 CL=98 CH=20
Warning
TF02-Pro-W-485 Only supports RTU mode to communicate in serial link.
Configuration Example
- Under RS-485 serial link mode, enable Modbus protocol:
- 5A 05 15 01 75 // Enable Modbus protocol
- 5A 04 11 6F // Save setting
Restart and enter Modbus mode.
- Under Modbus mode, disable Modbus Protocol:
- 01 06 00 82 00 01 E8 22 // Default address 01, disable Modbus
- 01 06 00 80 00 00 88 22 // Default address 01, save setting
- Restart and exit Modbus.
REV: 12/05/2022 · ©2022 Benewake (Beijing) Co., Ltd. | en.benewake.com | All rights reserved BP-UM-34 A01