sinocare Safe-Accu2

sinocare Safe-Accu2 Blood Glucose Meter Instruction Manual

Comprehensive guide for the safe and effective use of your sinocare Safe-Accu2 Blood Glucose Monitoring System.

1. Introduction

The sinocare Safe-Accu2 Blood Glucose Meter is designed for self-testing blood glucose levels. This manual provides essential information for the proper use and maintenance of your device. Regular monitoring of blood glucose is crucial for managing diabetes.

The Safe-Accu2 system offers accurate and reliable results with a small blood sample and quick testing time.

sinocare Safe-Accu2 Blood Glucose Meter with a person giving a thumbs up, indicating accuracy.

Image: The sinocare Safe-Accu2 Blood Glucose Meter, highlighting its accuracy and reliability.

2. What's in the Box

Your sinocare Safe-Accu2 Blood Glucose Monitoring System kit typically includes the following components:

  • sinocare Safe-Accu2 Blood Glucose Meter
  • Test Strips (quantity may vary by kit, e.g., 50 strips)
  • Lancing Device
  • Lancets (quantity may vary by kit, e.g., 50 lancets)
  • Carrying Case
  • User Manual
Contents of the sinocare Safe-Accu2 Blood Glucose Meter kit, including the meter, test strips, lancing device, and carrying case.

Image: Overview of the sinocare Safe-Accu2 Blood Glucose Meter kit components.

Detailed view of the sinocare Safe-Accu2 kit showing the meter, lancing device, test strip vials, and lancets.

Image: Detailed view of the sinocare Safe-Accu2 50-set kit components.

3. Product Overview

The sinocare Safe-Accu2 meter features a large, clear display and intuitive controls for ease of use. Key features include:

  • No Coding Required: Test strips are automatically calibrated.
  • Fast Results: Provides blood glucose readings in approximately 10 seconds.
  • Small Sample Size: Requires only 0.6 microliters of blood.
  • Memory Capacity: Stores up to 200 test results with date and time, including 7, 14, and 30-day averages.
  • Light Indicators: Red and green indicator lights provide immediate feedback on blood sugar levels.
Diagram illustrating the features of the sinocare Safe-Accu2 meter: Easy (No Code), Accurate (SOD Chip), Large (Larger Screen, More Clearly), Stable (4PIN & 3-electrode), Clear (Light indicates blood sugar level), Record (Time display), Little (0.6 Micro Liters), Wide (Red Blood Cell), Quick (10s Testing Time), Light (Portable to carry).

Image: Key features and design elements of the Safe-Accu2 meter.

Labeled diagram of the sinocare Safe-Accu2 meter and lancing device, showing the strip ejection button, test value display, date & time, red and green indicator lights, ON/OFF button, power button functions, time setting program, decrease/page down button, battery case, and details of the test strip and lancing device.

Image: Detailed diagram of the meter's components and controls.

4. Initial Setup

4.1. Battery Installation

The Safe-Accu2 meter uses 2*AAA Alkaline batteries. Open the battery compartment on the back of the device and insert the batteries according to the polarity indicators. Close the compartment securely.

4.2. Setting Date and Time

Upon first use or after battery replacement, you may need to set the date and time. Refer to the "Power Button" functions in the product overview diagram. Typically, pressing and holding the power button allows entry into the time setting program. Use the arrow buttons to adjust values and the power button to confirm.

5. Operating Instructions: Performing a Blood Glucose Test

  1. Prepare the Lancing Device:
    • Unscrew the cap of the lancing device.
    • Insert a new, sterile lancet firmly into the lancet holder.
    • Twist off the protective cap from the lancet.
    • Replace the lancing device cap.
    • Adjust the penetration depth by rotating the cap (settings 1-9, 3 is often suitable for average skin).
    • Pull back the cocking barrel until it clicks, indicating it's ready to use.
    Image showing the lancing device with adjustable depth settings and a diagram of how to dispose of used test strips.

    Image: Lancing device with adjustable depth and strip disposal mechanism.

  2. Insert a Test Strip:

    Insert a sinocare Accu-2 test strip into the meter's test strip port. The meter will automatically turn on and display a blood drop symbol, indicating it's ready for a blood sample. The meter does not require manual coding.

    Four-step instruction image for blood glucose testing: 1. Insert sinocare Accu-2 test strip. 2. Collect blood samples by Painfree lancing device. 3. Take blood sample from the top of sinocare Accu-2 test strip. 4. Test result in 10 seconds.

    Image: Step-by-step guide for performing a blood glucose test.

  3. Obtain a Blood Sample:

    Place the lancing device firmly against the side of your fingertip and press the release button. A small drop of blood will form. Gently squeeze your finger if necessary to obtain a sufficient sample (0.6 µL).

  4. Apply Blood to the Test Strip:

    Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip. The meter will beep and begin counting down.

  5. Read the Result:

    After approximately 10 seconds, your blood glucose result will appear on the display. The meter will also show a red or green light indicator:

    • Red Light: Blood sugar level ≤3.9mmol/L (low blood sugar) or blood sugar level ≥13.9mmol/L (high blood sugar). Consult a healthcare professional.
    • Green Light: Blood sugar level >3.9mmol/L and <13.9mmol/L (normal blood sugar).
    Diagram explaining the red and green light prompts on the sinocare Safe-Accu2 meter, indicating low, normal, or high blood sugar levels. Also includes a specification table.

    Image: Light prompt indicators for blood glucose levels.

  6. Dispose of Used Materials:

    Eject the used test strip from the meter using the strip ejection button. Carefully remove the used lancet from the lancing device and dispose of both safely in a sharps container or according to local regulations.

Important Notice for Accurate Results:

  • The operation of measuring blood sugar is best completed within 3 minutes.
  • After the test strip bottle is opened, the test strips inside need to be used up within 6 months.

6. Maintenance and Storage

6.1. Cleaning the Meter

Wipe the meter's exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure no liquid enters the test strip port.

6.2. Storage

  • Store the meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Keep test strip vials tightly closed after removing a strip.
  • Meter storage conditions: -20°C ~ 55°C.
  • Operating conditions: 10°C ~ 35°C (≤80%RH).

7. Troubleshooting

ProblemPossible CauseSolution
Meter does not turn on.Dead or incorrectly inserted batteries.Check battery orientation. Replace batteries if necessary.
Error message displayed.Improper test strip insertion, insufficient blood sample, or damaged strip.Ensure strip is inserted correctly. Re-test with a new strip and sufficient blood. Refer to the full manual for specific error codes.
Inconsistent results.Expired test strips, improper storage, or incorrect testing procedure.Check strip expiry date. Ensure strips are stored correctly. Review testing steps carefully. Consult a healthcare professional if concerns persist.
Lancing device does not prick.Not cocked, or lancet not inserted correctly.Ensure the lancing device is cocked. Check that a new lancet is inserted firmly.

For further assistance, please refer to the complete user manual or contact sinocare customer support.

8. Specifications

FeatureDetail
SystemFAD-GDH
Blood Volume0.6 µL
Sample TypeCapillary whole blood, Venous whole blood
CalibrationPlasma equivalent
Test Time10 seconds
Meter Storage Conditions-20°C ~ 55°C
Operating Conditions10°C ~ 35°C (≤80%RH)
HCT (Hematocrit)30% - 60%
Test Range1.1 - 33.3 mmol/L
Memory200 test results with date & time
Battery2*AAA Alkaline batteries

Note: Specifications are subject to change without notice.

9. Important Safety Information

  • This device is intended for in vitro diagnostic use only. Do not use for diagnosis of diabetes, but as an aid in monitoring diabetes management.
  • Consult your healthcare professional before making any changes to your medication, diet, or exercise program based on your blood glucose results.
  • Keep the meter, test strips, and lancets out of reach of children.
  • Always use fresh, sterile lancets and unexpired test strips.
  • Dispose of used lancets and test strips properly in a puncture-resistant container to prevent injury and infection.
  • Do not use the meter if it appears damaged or is not functioning correctly.
  • The system is indicated for monitoring blood glucose, including diabetes control.

10. Warranty and Support

For warranty information, please refer to the documentation included with your product or contact sinocare customer service. sinocare is committed to providing satisfactory after-sales service.

For video user guidance, you may visit the following external resource: sinocare Safe-Accu2 Video Guide.

If you require a PDF manual in other languages, please contact sinocare customer support through Amazon or their official channels.

Related Documents - Safe-Accu2

Preview Sinocare Safe AQ Voice Quick Guide: Easy Blood Glucose Monitoring
A concise guide to using the Sinocare Safe AQ Voice blood glucose meter for quick and accurate blood sugar testing. Learn how to prepare materials, perform the test, and interpret results.
Preview Safe AQ Smart, Safe AQ Voice, Safe AQ Air Blood Glucose Meter User Manual
Comprehensive user manual for the Sinocare Safe AQ Smart, Safe AQ Voice, and Safe AQ Air blood glucose monitoring systems. Learn about intended use, safety information, test principles, operation, troubleshooting, and maintenance.
Preview Sinocare Safe AQ Smart Blood Glucose Meter - Operation Manual
Concise operation manual for the Sinocare Safe AQ Smart blood glucose meter, detailing preparation, usage steps, and important notes for accurate blood sugar testing.
Preview Sinocare Safe AQ Pro Series Blood Glucose Monitoring System User Manual
This user manual provides comprehensive instructions for the Sinocare Safe AQ Pro Series Blood Glucose Monitoring System, covering setup, operation, maintenance, troubleshooting, and important safety information for accurate blood glucose level monitoring.
Preview Safe-Accu Blood Glucose Monitoring System User Manual
User manual for the Sinocare Safe-Accu Blood Glucose Monitoring System, providing instructions on setup, testing, maintenance, and troubleshooting.
Preview Safe-Accu 2 Blood Glucose Meter User Manual - Sinocare
Comprehensive user manual for the Sinocare Safe-Accu 2 Blood Glucose Monitoring System. Learn how to set up, test, and maintain your device for effective diabetes management.