Ledvion LVT10001_1m2s_2700K

Ledvion 1M LED Track Lighting System with 2 Dimmable 2700K Spotlights

Model: LVT10001_1m2s_2700K

Introduction

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of your Ledvion 1M LED Track Lighting System. Please read this manual thoroughly before installation and retain it for future reference.

Safety Information

Product Overview

The Ledvion 1M LED Track Lighting System offers a modern and flexible lighting solution for various indoor environments. This single-phase track system includes two adjustable spotlights with GU10 fittings, allowing for customizable illumination.

Key Features:

Ledvion 1M LED Track Lighting System with two spotlights.

An overhead view of the Ledvion 1-meter black LED track lighting system, featuring two adjustable spotlights emitting warm white light.

What's in the Box

Verify that all components are present and undamaged before beginning installation.

Contents of the Ledvion 1M LED Track Lighting System package.

An overhead view of all components included in the Ledvion track lighting package: the 1-meter track, two spotlights, two GU10 bulbs, two anti-glare grids, mounting screws, wall anchors, and a power connector.

Setup and Installation

Follow these steps for proper installation of your Ledvion track lighting system.

  1. Plan Layout: Determine the desired location for your track rail. Ensure it is within reach of a power source.
  2. Mark Mounting Points: Hold the track rail against the ceiling or wall and mark the drilling points for the mounting screws.
  3. Drill Holes: Drill pilot holes at the marked points and insert wall anchors if necessary.
  4. Mount Track Rail: Securely attach the track rail to the ceiling or wall using the provided screws.
  5. Connect Power: Install the power connector at one end of the track. Connect the electrical wiring from your power source to the power connector. Ensure all connections are secure and insulated. For more complex setups, optional power feeders and connectors (I-connector, X-connector, T-connector) are available.
  6. Install Spotlights: Insert the GU10 LED lamps into the spotlights. Then, align the spotlights with the track and use the plug-and-play locking system to secure them. Rotate the locking mechanism to fix the spotlight in place.
  7. Adjust Spotlights: Once installed, adjust the angle and rotation of each spotlight to direct light as desired.
  8. Restore Power: Once installation is complete and all connections are secure, restore power at the main circuit breaker.
Steps for Ledvion track spotlight plug-and-play installation.

A visual guide demonstrating the simple plug-and-play installation of the Ledvion track spotlights, showing how they easily lock into the track system.

Optional accessories for Ledvion track lighting system.

An illustration showing various optional accessories for the Ledvion track lighting system, including power feeders, X-connector, T-connector, and a pendant spot with adjustable cord, indicating system expandability.

Operating Instructions

Adjusting Light Direction:

Each spotlight can be independently adjusted to direct light precisely where needed. The spotlights can be tilted up to 350 degrees and rotated 90 degrees along the track.

Ledvion spotlight demonstrating 350-degree tilt and 90-degree rotation.

An animated graphic illustrating the Ledvion track spotlight's adjustability, showing it can be tilted 350 degrees and rotated 90 degrees to direct light precisely.

Dimming Functionality:

This track lighting system is compatible with external dimmers. If you have an external dimmer installed, you can adjust the light intensity by operating the dimmer switch. Ensure that the GU10 lamps used are dimmable.

Optional Anti-Glare Grid:

The included anti-glare grids can be easily added or removed from the spotlights to prevent glare and enhance visual comfort.

Ledvion spotlight with optional anti-glare grid.

A Ledvion spotlight shown with an optional anti-glare grid, designed to reduce light glare and improve visual comfort. The grid is easy to add and remove.

Maintenance

Cleaning:

To clean the track and spotlights, ensure the power is off. Use a soft, dry cloth to wipe away dust. For stubborn marks, a slightly damp cloth can be used, followed by immediate drying. Do not use abrasive cleaners or solvents.

Lamp Replacement:

Before replacing a lamp, turn off the power and allow the lamp to cool completely. Gently twist the GU10 lamp counter-clockwise to remove it. Insert the new GU10 lamp by aligning the pins and twisting clockwise until secure. Ensure the replacement lamp matches the specifications (GU10 base, appropriate wattage, and dimmable if using a dimmer).

Troubleshooting

Specifications

FeatureSpecification
BrandLedvion
Model NumberLVT10001_1m2s_2700K
Product Dimensions (L x W x H)105 x 15 x 5 cm
Item Weight1.08 Kilograms
MaterialAluminum
Number of Bulbs2
Voltage230 Volts
Wattage (per bulb)5 Watts (as per title, 3 Watts in some specs)
Luminous Flux (per bulb)240 Lumen
Color Temperature2700 Kelvin (Warm White)
Energy Efficiency ClassD
Installation TypeTrack Mounting
Specific UsesHome, Offices, Shops
Indoor/Outdoor UseIndoor
Country of OriginChina
EPREL Product InformationView EPREL Database
Dimensions of Ledvion track lighting components.

An image displaying the key dimensions of the Ledvion track lighting system, including the 1000mm track length, 150mm total spotlight height, 115mm spotlight body height, and 50mm spotlight diameter.

Ledvion energy efficiency label.

The EU energy label for Ledvion model LVB10002_1, indicating an energy efficiency class D and 3 kWh/1000h consumption, with a QR code for more information.

Warranty and Support

Ledvion products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your product or visit the official Ledvion website. For technical support, troubleshooting assistance, or inquiries about replacement parts, please contact Ledvion customer service through their official channels.

Related Documents - LVT10001_1m2s_2700K

Preview Ledvion GU10 Ground Spot Installation Manual
Installation instructions and safety information for the Ledvion GU10 Ground Spot (ART.NO.LVO10137 & LVO10139). Includes details on electrical safety, maintenance, and disposal.
Preview Ledvion LV010040 Outdoor Wall Lamp: Installation Guide & Safety Information
Comprehensive installation instructions, safety guidelines, and technical specifications for the Ledvion LV010040 outdoor wall lamp. Ensure safe and correct setup for your lighting.
Preview Ledvion IP65 Fixture with T8 Fitting Installation Guide and Technical Data
Comprehensive installation instructions, technical specifications, safety guidelines, and compliance information for the Ledvion IP65 Fixture with T8 Fitting, covering models LV30001 through LV30006.
Preview Ledvion IP65 Fixture with T8 Fitting: Installation Guide and Technical Specifications
Detailed installation instructions and technical data for the Ledvion IP65 rated fixture with T8 fitting. Covers model numbers LV30013-LV30018, voltage, frequency, protection, dimensions, and step-by-step mounting procedures. Includes safety warnings and compliance information.
Preview Ledvion LED Dimmer Manual and Technical Data
Comprehensive manual for the Ledvion LED Dimmer switch (LV10001_1), including installation instructions, wiring diagrams, technical specifications, and safety warnings. Learn how to properly install and use the dimmer for optimal performance with dimmable LED lamps.
Preview Ledvion LVS10026 Outdoor LED Solar Garden Light: Installation & Safety Guide
Comprehensive guide for the Ledvion LVS10026 outdoor LED solar garden light, covering installation, safety precautions, care, and disposal. Features technical specifications and compliance details.