Ledvion IP65 Fixture with T8 Fitting

Model Series: LV30001, LV30002, LV30003, LV30004, LV30005 & LV30006

Manufacturer: Ledvion

Address: 5692 DH Son en Breugel, Ekkersrijt 4304, The Netherlands

Website: www.ledvion.com

Technical Data

ModelVoltageFrequency (Hz)ProtectionDimensions
LV30001AC220-240V50/60 HzIP65668x62x58mm
LV30002AC220-240V50/60 HzIP651272x62x58mm
LV30003AC220-240V50/60 HzIP651572x62x58mm
LV30004AC220-240V50/60 HzIP65668x100x55mm
LV30005AC220-240V50/60 HzIP651272x100x55mm
LV30006AC220-240V50/60 HzIP651572x100x55mm

Included Accessories

The following accessories are included with the fixture:

  • Mounting clips: 2x
  • Cable glands: 2x
  • Screws for mounting clips: 4x

Note: Specific quantities for different fixture lengths (0.6M, 1.2M, 1.5M) may vary for other components not explicitly detailed here.

Installation Instructions

  1. Step 1: Power Off. Ensure the main power supply is turned off before proceeding.

    [Illustration: Hand switching off a power breaker or switch labeled 'OFF'.]
  2. Step 2: Identify Components. Identify the IP65 fixture and the provided mounting brackets.

    [Illustration: The LED fixture and two mounting brackets.]
  3. Step 3: Position Brackets. Position the mounting brackets on the surface where the fixture will be installed.

    [Illustration: Mounting brackets being attached to a surface.]
  4. Step 4: Secure Brackets. Securely attach the mounting brackets to the surface using appropriate fixings (screws provided).

    [Illustration: A screwdriver being used to fasten a bracket.]
  5. Step 5: Cable Entry. Insert the power cable through a cable gland. Ensure the cable entry point is approximately 30±5mm from the end of the fixture and the cable diameter is 8-10mm.

    [Illustration: Power cable entering a gland with dimensions 30±5mm and 8-10mm indicated.]
  6. Step 6: Wire Connection. Connect the electrical wires inside the fixture according to local electrical codes and standards.

    [Illustration: Electrical wires being connected within the fixture.]
  7. Step 7: Mount Fixture. Carefully mount the fixture onto the secured mounting brackets.

    [Illustration: The fixture being attached to the mounted brackets.]
  8. Step 8: Close Fixture. Securely close the fixture cover to maintain its IP65 rating.

    [Illustration: The fixture cover being closed.]
  9. Step 9: Final Check. Before restoring power, ensure all connections are secure and the fixture is properly sealed. Warning: Risk of electric shock.

    [Illustration: A warning symbol (lightning bolt) and a person observing the fixture.]
  10. Step 10: Installation Complete. The fixture is now installed.

    [Illustration: The fully installed fixture.]
  11. Step 11: Mounting Hole Dimensions. Refer to the table below for specific mounting hole dimensions (X and Y) based on the model.

    ModelXY
    LV30001350±10mm16mm
    LV30002836±10mm16mm
    LV300031136±10mm16mm
    LV30004350±10mm16mm
    LV30005836±10mm16mm
    LV300061136±10mm16mm
  12. Step 12: Linking Fixtures. Use the integrated mechanism to connect multiple fixtures together. A 'click' sound indicates a secure connection.

    [Illustration: Two fixtures being connected, showing a 'click' mechanism.]
  13. Step 13: Linked Installation. Multiple fixtures can be linked to create longer lighting runs.

    [Illustration: Several fixtures linked together.]
  14. Step 14: Tools Required (Not Included). The following tools are necessary for installation but are not supplied with the product: Drill, Tape Measure, Screwdriver, Pencil.

    [Illustration: Icons representing a drill, tape measure, screwdriver, and pencil.]

Features

Easy Linkable: This fixture is designed for easy linking, allowing for continuous lighting installations.

Safety, Care, and Disposal

General Safety & Care

  • Read the manual carefully before use and keep it for future reference.
  • Use the product only for its intended purposes.
  • Do not use the product if any part is damaged or defective. Replace immediately if damaged or defective.
  • This product is not intended for unsupervised use by children. Children should not play with the device.
  • Do not modify the product in any way.
  • Keep the product away from heat sources.
  • Do not block ventilation openings.
  • Do not look directly into the LED lamp.
  • Maintain a minimum distance of 1 meter between the lamp and the illuminated surface.
  • Before cleaning, disconnect the unit. Do not use aggressive cleaning agents.

Electrical Safety

  • To reduce the risk of electric shock, this product should only be opened by an authorized technician when service is required.
  • Do not use the product if the cable or plug is damaged or defective. It must be replaced by the manufacturer or an authorized repair agent.
  • Always ensure the mains voltage matches the voltage on the device's rating plate.
  • Ensure the cable does not hang over the edge of a worktop and cannot be accidentally caught or tripped over.
  • The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similarly qualified person.
  • Caution: Risk of electric shock.
  • The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire must be destroyed.

Disposal

  • The product is designated for separate collection at an appropriate collection point.
  • Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.

Disclaimer

  • Designs and specifications are subject to change without notice.
  • All logos, brands, and product names are trademarks or registered trademarks of their respective holders and are hereby recognized as such.
  • Visit www.ledvion.com for more information about the company and its products.

Compliance and Documentation

CE Declaration

This product complies with the following directives:

  • LVD: 2014/35/EU
  • EMC: 2014/30/EU
  • RoHS: 2011/65/EU
  • For products with Radio transmitter units: RED: 2014/53/EU

The complete Declaration of Conformity (DoC) can be found on the Ledvion website.

Documentation

The product has been manufactured and supplied in compliance with all relevant regulations and directives valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sales.

Formal documentation, including the Declaration of Conformity, Material Safety Data Sheet, and product test report, is available upon request.

Models: LV30001 LED Linear Light, LV30001, LED Linear Light, Linear Light, Light

File Info : application/pdf, 4 Pages, 2.36MB

PDF preview unavailable. Download the PDF instead.

lv30001-manual \n

References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Macintosh)

Related Documents

Preview Ledvion LED Tube Installation Guide and Technical Specifications (LV20011-LV20016)
Comprehensive installation instructions and technical data for Ledvion LED Tubes, models LV20011 through LV20016. Learn about safe installation, wiring, and product specifications.
Preview Ledvion LED High Bay Installation Guide and Technical Specifications
Detailed installation instructions and technical specifications for Ledvion LED High Bay luminaires, covering models LV70001 through LV70016. Includes safety guidelines, wiring diagrams, and accessory information.
Preview Ledvion LED High Bay Installation Manual and Specifications
Comprehensive installation guide and technical specifications for Ledvion LED High Bay lights, covering models LV70001 through LV70016. Includes safety precautions, installation steps, and accessory information.
Preview Ledvion LED High Bay Installation and Technical Guide
Comprehensive guide for installing and understanding the specifications of Ledvion LED High Bay lights, including technical data, accessories, and safety instructions.
Preview Ledvion GU10 Ground Spot Installation Manual
Installation instructions and safety information for the Ledvion GU10 Ground Spot (ART.NO.LVO10137 & LVO10139). Includes details on electrical safety, maintenance, and disposal.
Preview Ledvion LV010040 Outdoor Wall Lamp: Installation Guide & Safety Information
Comprehensive installation instructions, safety guidelines, and technical specifications for the Ledvion LV010040 outdoor wall lamp. Ensure safe and correct setup for your lighting.
Preview Ledvion Outdoor Wall Lamp Installation Guide
Provides installation instructions and technical details for the Ledvion Outdoor Wall Lamp (ART.NO.LVO10028_1), including wiring and mounting guidance.
Preview Ledvion LVS10013 Solar LED Wall Light with Sensor - User Manual
Detailed specifications, installation guide, working modes, and features of the Ledvion LVS10013 Ultra-Bright Solar LED Wall Light with PIR sensor. Includes information on battery replacement and safety warnings.