Technical Data
Model | Voltage | Frequency (Hz) | Protection | Dimensions |
---|---|---|---|---|
LV30001 | AC220-240V | 50/60 Hz | IP65 | 668x62x58mm |
LV30002 | AC220-240V | 50/60 Hz | IP65 | 1272x62x58mm |
LV30003 | AC220-240V | 50/60 Hz | IP65 | 1572x62x58mm |
LV30004 | AC220-240V | 50/60 Hz | IP65 | 668x100x55mm |
LV30005 | AC220-240V | 50/60 Hz | IP65 | 1272x100x55mm |
LV30006 | AC220-240V | 50/60 Hz | IP65 | 1572x100x55mm |
Included Accessories
The following accessories are included with the fixture:
- Mounting clips: 2x
- Cable glands: 2x
- Screws for mounting clips: 4x
Note: Specific quantities for different fixture lengths (0.6M, 1.2M, 1.5M) may vary for other components not explicitly detailed here.
Installation Instructions
Step 1: Power Off. Ensure the main power supply is turned off before proceeding.
[Illustration: Hand switching off a power breaker or switch labeled 'OFF'.]Step 2: Identify Components. Identify the IP65 fixture and the provided mounting brackets.
[Illustration: The LED fixture and two mounting brackets.]Step 3: Position Brackets. Position the mounting brackets on the surface where the fixture will be installed.
[Illustration: Mounting brackets being attached to a surface.]Step 4: Secure Brackets. Securely attach the mounting brackets to the surface using appropriate fixings (screws provided).
[Illustration: A screwdriver being used to fasten a bracket.]Step 5: Cable Entry. Insert the power cable through a cable gland. Ensure the cable entry point is approximately 30±5mm from the end of the fixture and the cable diameter is 8-10mm.
[Illustration: Power cable entering a gland with dimensions 30±5mm and 8-10mm indicated.]Step 6: Wire Connection. Connect the electrical wires inside the fixture according to local electrical codes and standards.
[Illustration: Electrical wires being connected within the fixture.]Step 7: Mount Fixture. Carefully mount the fixture onto the secured mounting brackets.
[Illustration: The fixture being attached to the mounted brackets.]Step 8: Close Fixture. Securely close the fixture cover to maintain its IP65 rating.
[Illustration: The fixture cover being closed.]Step 9: Final Check. Before restoring power, ensure all connections are secure and the fixture is properly sealed. Warning: Risk of electric shock.
[Illustration: A warning symbol (lightning bolt) and a person observing the fixture.]Step 10: Installation Complete. The fixture is now installed.
[Illustration: The fully installed fixture.]Step 11: Mounting Hole Dimensions. Refer to the table below for specific mounting hole dimensions (X and Y) based on the model.
Model X Y LV30001 350±10mm 16mm LV30002 836±10mm 16mm LV30003 1136±10mm 16mm LV30004 350±10mm 16mm LV30005 836±10mm 16mm LV30006 1136±10mm 16mm Step 12: Linking Fixtures. Use the integrated mechanism to connect multiple fixtures together. A 'click' sound indicates a secure connection.
[Illustration: Two fixtures being connected, showing a 'click' mechanism.]Step 13: Linked Installation. Multiple fixtures can be linked to create longer lighting runs.
[Illustration: Several fixtures linked together.]Step 14: Tools Required (Not Included). The following tools are necessary for installation but are not supplied with the product: Drill, Tape Measure, Screwdriver, Pencil.
[Illustration: Icons representing a drill, tape measure, screwdriver, and pencil.]
Features
Easy Linkable: This fixture is designed for easy linking, allowing for continuous lighting installations.
Safety, Care, and Disposal
General Safety & Care
- Read the manual carefully before use and keep it for future reference.
- Use the product only for its intended purposes.
- Do not use the product if any part is damaged or defective. Replace immediately if damaged or defective.
- This product is not intended for unsupervised use by children. Children should not play with the device.
- Do not modify the product in any way.
- Keep the product away from heat sources.
- Do not block ventilation openings.
- Do not look directly into the LED lamp.
- Maintain a minimum distance of 1 meter between the lamp and the illuminated surface.
- Before cleaning, disconnect the unit. Do not use aggressive cleaning agents.
Electrical Safety
- To reduce the risk of electric shock, this product should only be opened by an authorized technician when service is required.
- Do not use the product if the cable or plug is damaged or defective. It must be replaced by the manufacturer or an authorized repair agent.
- Always ensure the mains voltage matches the voltage on the device's rating plate.
- Ensure the cable does not hang over the edge of a worktop and cannot be accidentally caught or tripped over.
- The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similarly qualified person.
- Caution: Risk of electric shock.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire must be destroyed.
Disposal
- The product is designated for separate collection at an appropriate collection point.
- Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.
Disclaimer
- Designs and specifications are subject to change without notice.
- All logos, brands, and product names are trademarks or registered trademarks of their respective holders and are hereby recognized as such.
- Visit www.ledvion.com for more information about the company and its products.
Compliance and Documentation
CE Declaration
This product complies with the following directives:
- LVD: 2014/35/EU
- EMC: 2014/30/EU
- RoHS: 2011/65/EU
- For products with Radio transmitter units: RED: 2014/53/EU
The complete Declaration of Conformity (DoC) can be found on the Ledvion website.
Documentation
The product has been manufactured and supplied in compliance with all relevant regulations and directives valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sales.
Formal documentation, including the Declaration of Conformity, Material Safety Data Sheet, and product test report, is available upon request.