sygonix SY-5836544

Sygonix SY-5836544 Twilight Switch User Manual

Model: SY-5836544

Brand: Sygonix

1. Product Overview

The Sygonix SY-5836544 Twilight Switch is an intelligent device designed for automatic control of lighting systems based on ambient light conditions. It ensures that your lights turn on at dusk and off at dawn, providing convenience and energy efficiency. Its robust design, including an IP66 rating, makes it suitable for both indoor and outdoor installations.

Sygonix SY-5836544 Twilight Switch, front view

Figure 1: Front view of the Sygonix SY-5836544 Twilight Switch. This image shows the white translucent dome on top and the black base with two cable glands and a mounting bracket, indicating its readiness for installation.

Key Features:

2. Setup

Before beginning installation, ensure that the main power supply to the circuit is disconnected to prevent electric shock. Installation should be performed by a qualified electrician if you are unsure about any steps.

2.1 Mounting

The twilight switch is designed for wall mounting. Select a location that receives adequate ambient light and is not obstructed by shadows, especially during twilight hours. The IP66 rating allows for both indoor and outdoor installation.

  1. Mark the drilling points on the desired mounting surface using the switch's mounting bracket as a template.
  2. Drill holes suitable for your mounting screws (not included).
  3. Securely attach the twilight switch to the surface using appropriate screws and wall plugs.
Sygonix SY-5836544 Twilight Switch, side view with mounting bracket

Figure 2: Side view of the Sygonix SY-5836544 Twilight Switch, illustrating the robust black mounting bracket extending from the base, designed for secure wall attachment. This view also shows one of the cable glands.

2.2 Wiring

The twilight switch operates on 230 V/AC and features Normally Open (NO) screw terminals for connection. Ensure all connections are tight and secure.

  1. Carefully open the housing of the twilight switch to access the wiring terminals.
  2. Feed the power supply cables and the load cables (to your lighting fixture) through the designated cable glands.
  3. Connect the live (L), neutral (N), and earth (PE) wires according to the wiring diagram provided inside the device or in the full product manual. The switch acts as a single-pole switch for the live wire.
  4. Ensure all connections are made to the correct screw terminals.
  5. Tighten the cable glands to ensure a watertight and dust-tight seal, maintaining the IP66 rating.
  6. Close the housing securely.
Sygonix SY-5836544 Twilight Switch, front view showing cable glands

Figure 3: Front view of the Sygonix SY-5836544 Twilight Switch, clearly showing the two black cable glands at the bottom. These glands are crucial for securing and sealing the electrical cables, contributing to the device's IP66 protection rating.

3. Operating

The Sygonix SY-5836544 Twilight Switch operates automatically based on the ambient light level. There are no manual controls for daily operation once installed and configured.

4. Maintenance

The Sygonix SY-5836544 Twilight Switch requires minimal maintenance due to its durable construction and IP66 rating.

5. Troubleshooting

If you experience issues with your Sygonix SY-5836544 Twilight Switch, consider the following common troubleshooting steps:

6. Technical Specifications

PropertyValue
Product Dimensions (L x W x H)7.8 x 7.8 x 9.3 cm
First Available on Amazon.frMarch 19, 2024
ManufacturerSygonix
ASINB0CYLQDLGF
Item Model NumberSY-5836544
Country of OriginChina
Intended UseGeneral Use
Spare Parts AvailabilityInformation Unavailable
Operating ModeAutomatic
Current Rating1 A
Operating Voltage230 Volts
Contact TypeNormally Open (NO)
Brandsygonix
Terminal TypeScrew
Circuit Type1-Way
Actuator TypeLight Sensor
International Protection RatingIP66

7. Warranty and Support

Sygonix products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or contact your retailer.

For technical support, troubleshooting assistance beyond this manual, or inquiries about spare parts, please contact Sygonix customer service or the authorized seller from whom you purchased the product. Please have your model number (SY-5836544) and purchase details ready when contacting support.

You can often find additional support resources, FAQs, and contact information on the official Sygonix website or the retailer's support page.

Related Documents - SY-5836544

Preview Manuale Utente Interruttore Crepuscolare Sygonix 2918272 IP66 - Installazione e Funzionamento
Manuale d'uso completo per l'interruttore crepuscolare Sygonix 2918272 IP66. Include istruzioni dettagliate su installazione, funzionamento, sicurezza, risoluzione dei problemi e dati tecnici per garantire un utilizzo ottimale.
Preview Instrukcja obsługi zamka kodowego RFID/IP66 Sygonix
Instrukcja obsługi dla zamka kodowego RFID/IP66 Sygonix, zawierająca informacje o montażu, podłączaniu, programowaniu i bezpieczeństwie.
Preview Sygonix RFID/Code Lock IP66 Programming Codes Overview
This document provides an overview of the programming codes for the Sygonix RFID/Code Lock IP66, detailing configuration functions, input formats, and default parameters.
Preview Sygonix RFID/Code Lock IP66 Operating Instructions
Comprehensive operating instructions for the Sygonix RFID/Code Lock IP66, detailing installation, programming, features, and safety guidelines.
Preview Sygonix RFID/Code Lock IP66 Operating Instructions
Comprehensive operating instructions for the Sygonix RFID/Code Lock IP66, detailing installation, programming, features, and safety guidelines for secure access control.
Preview Sygonix RFID/Code Lock IP66 Programming Codes Overview
This document provides a comprehensive overview of the programming codes for the Sygonix RFID/Code Lock IP66, detailing functions, values, insertion modes, and factory settings for various programming operations.