Pedrollo 3CRm100-N

User Manual: Multi Stage Centrifugal Pump

Model: 3CRm100-N | Brand: Pedrollo

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Pedrollo Multi Stage Centrifugal Pump, model 3CRm100-N. This pump is designed for use with clean water and liquids that are not chemically aggressive towards its components. Its quiet operation makes it suitable for domestic water distribution systems, small to medium pressure sets, and garden irrigation.

Pedrollo 3CRm100-N Multi Stage Centrifugal Pump

Figure 1: Pedrollo 3CRm100-N Multi Stage Centrifugal Pump. This image shows the pump from a slightly elevated angle, highlighting its polished stainless steel body and blue electric motor housing. The pump features a red and white "CR" logo on its side.

2. Safety Information

Always observe the following safety precautions to prevent injury and damage to the pump:

3. Product Features

The Pedrollo 3CRm100-N pump offers the following key features:

4. Setup and Installation

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a qualified professional.

  1. Location: Install the pump in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure sufficient space for maintenance.
  2. Mounting: Securely mount the pump on a stable, level surface using appropriate fasteners to minimize vibration.
  3. Piping Connections: Connect the suction and discharge pipes. Ensure all connections are airtight to prevent air leaks, which can affect pump performance. Use NPT threaded fittings as specified.
  4. Priming: Before initial operation, the pump must be primed. Fill the pump casing and suction line completely with water through the priming port until all air is expelled.
  5. Electrical Connection: Connect the pump to a suitable power supply (115V/60Hz) according to local electrical codes. Ensure proper grounding. A dedicated circuit is recommended.
  6. Check Valves: Install a foot valve with a strainer at the end of the suction line to prevent debris entry and maintain prime. A check valve on the discharge side is also recommended to prevent backflow.

5. Operating Instructions

Follow these steps for safe and effective operation of your pump:

  1. Initial Start-up: After installation and priming, ensure all valves are open as required. Turn on the power supply to the pump.
  2. Monitoring: During operation, monitor the pump for unusual noises, vibrations, or leaks. Ensure consistent water flow.
  3. Stopping the Pump: To stop the pump, turn off the power supply. If the pump will be out of service for an extended period, drain it to prevent freezing or stagnation.
  4. Dry Running: Never allow the pump to run dry, as this can cause severe damage to the mechanical seal and other components.

6. Maintenance

Regular maintenance ensures optimal performance and extends the life of your pump. Always disconnect power before performing any maintenance.

7. Troubleshooting

This section provides solutions for common issues. For problems not listed, contact customer support.

ProblemPossible CauseSolution
Pump does not startNo power; tripped circuit breaker; motor overload; seized impeller.Check power supply and connections; reset breaker; allow motor to cool; inspect impeller for obstructions.
Pump runs but no water flowPump not primed; air leak in suction line; clogged suction strainer; low water level at source.Re-prime the pump; check all suction connections for leaks; clean strainer; ensure adequate water supply.
Reduced flow or pressurePartial blockage in piping; worn impeller; air in system; incorrect pipe size.Inspect and clear blockages; check for air leaks; consult a professional for impeller inspection.
Excessive noise or vibrationCavitation (air in pump); loose mounting; bearing wear; foreign object in pump.Ensure pump is fully primed and no air leaks; tighten mounting bolts; contact service for bearing issues; inspect for debris.

8. Technical Specifications

AttributeValue
BrandPedrollo
Model3CRm100-N
Pump StyleCentrifugal, Horizontal Multistage
Power SourceAC/DC (115V/60Hz, 0.75HP)
Liquid TypeClean water
Liquid Temperature Range-10 °C to +40 °C
Ambient TemperatureUp to +40 °C
Manometric Suction LiftUp to 7 m
Max. Working Pressure7 bar
Continuous ServiceS1
ConnectionsNPT Threaded
UPC722777873594
ASINB09HL5N9WW

9. Warranty and Support

For warranty information, technical support, or to purchase replacement parts, please contact Pedrollo customer service or visit their official website. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, you may refer to the product page on Amazon: Product Link

Related Documents - 3CRm100-N

Preview Pedrollo UP Series Multi-stage Submersible Pumps: Performance, Specifications, and Installation
Detailed information on Pedrollo UP Series multi-stage submersible pumps, including performance range, application limits, construction details, characteristic curves, dimensions, and installation guidelines. Ideal for domestic, civil, and agricultural use.
Preview Pedrollo TOP MULTI-TECH Automatic Submersible Pumps: Specifications & Performance
Detailed technical specifications, performance curves, installation guide, and features for the Pedrollo TOP MULTI-TECH series of multi-stage automatic submersible pumps, designed for clean water applications.
Preview Pedrollo TOP MULTI-TECH & TOP MULTI-EVOTECH Automatic Submersible Water Pumps - Operation Manual
This document provides operational guidance for the Pedrollo TOP MULTI-TECH and TOP MULTI-EVOTECH automatic submersible multi-stage water pumps. It covers general information, operation, protections, and typical installation advice.
Preview Pedrollo TOP MULTI-TECH / TOP MULTI-EVOTECH Automatic Submersible Water Pump Operation Manual
This document provides operational instructions for the Pedrollo TOP MULTI-TECH and TOP MULTI-EVOTECH automatic submersible multi-stage water pumps. It covers general information, operating principles, installation advice, and protection features for optimal performance and longevity.
Preview Pedrollo TURBO Series Centrifugal Pumps: Technical Specifications, Performance, and Applications
Detailed technical specifications, performance curves, dimensions, and application information for the Pedrollo TURBO series of two-stage centrifugal electric pumps, designed for clean water applications in domestic, civil, agricultural, and industrial sectors.
Preview Pedrollo PLURIJET 80-100 & 80X-100X Self-Priming Multi-Stage Pumps Datasheet
Comprehensive technical specifications, performance data, installation guidance, and construction details for the Pedrollo PLURIJET 80-100 and PLURIJET 80X-100X series of self-priming multi-stage pumps, suitable for domestic and civil applications.