1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Pedrollo Multi Stage Centrifugal Pump, model 3CRm100-N. This pump is designed for use with clean water and liquids that are not chemically aggressive towards its components. Its quiet operation makes it suitable for domestic water distribution systems, small to medium pressure sets, and garden irrigation.

Figure 1: Pedrollo 3CRm100-N Multi Stage Centrifugal Pump. This image shows the pump from a slightly elevated angle, highlighting its polished stainless steel body and blue electric motor housing. The pump features a red and white "CR" logo on its side.
2. Safety Information
Always observe the following safety precautions to prevent injury and damage to the pump:
- Ensure the pump is properly grounded to prevent electrical shock.
- Do not operate the pump with damaged electrical cords or plugs.
- Disconnect power before performing any maintenance or service.
- Do not pump flammable or explosive liquids.
- Ensure adequate ventilation around the motor to prevent overheating.
- Keep children and unauthorized personnel away from the operating pump.
- Wear appropriate personal protective equipment (PPE) when handling or servicing the pump.
3. Product Features
The Pedrollo 3CRm100-N pump offers the following key features:
- Liquid Type: Designed for clean water.
- Applications: Suitable for domestic and civil uses, including water supply systems, pressure sets, and irrigation.
- Typology: Surface pump.
- Family: Horizontal multistage pump.
- Temperature Range: Operates with liquid temperatures from -10 °C to +40 °C.
- Ambient Temperature: Designed for ambient temperatures up to +40 °C.
- Suction Lift: Manometric suction lift up to 7 meters.
- Working Pressure: Maximum working pressure of 7 bar.
- Service: Continuous service (S1).
4. Setup and Installation
Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a qualified professional.
- Location: Install the pump in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure sufficient space for maintenance.
- Mounting: Securely mount the pump on a stable, level surface using appropriate fasteners to minimize vibration.
- Piping Connections: Connect the suction and discharge pipes. Ensure all connections are airtight to prevent air leaks, which can affect pump performance. Use NPT threaded fittings as specified.
- Priming: Before initial operation, the pump must be primed. Fill the pump casing and suction line completely with water through the priming port until all air is expelled.
- Electrical Connection: Connect the pump to a suitable power supply (115V/60Hz) according to local electrical codes. Ensure proper grounding. A dedicated circuit is recommended.
- Check Valves: Install a foot valve with a strainer at the end of the suction line to prevent debris entry and maintain prime. A check valve on the discharge side is also recommended to prevent backflow.
5. Operating Instructions
Follow these steps for safe and effective operation of your pump:
- Initial Start-up: After installation and priming, ensure all valves are open as required. Turn on the power supply to the pump.
- Monitoring: During operation, monitor the pump for unusual noises, vibrations, or leaks. Ensure consistent water flow.
- Stopping the Pump: To stop the pump, turn off the power supply. If the pump will be out of service for an extended period, drain it to prevent freezing or stagnation.
- Dry Running: Never allow the pump to run dry, as this can cause severe damage to the mechanical seal and other components.
6. Maintenance
Regular maintenance ensures optimal performance and extends the life of your pump. Always disconnect power before performing any maintenance.
- Regular Inspection: Periodically check for leaks, unusual noises, or excessive vibration.
- Cleanliness: Keep the pump and motor free from dirt, dust, and debris to ensure proper cooling.
- Strainer Cleaning: If a foot valve with a strainer is used, periodically check and clean the strainer to prevent blockages.
- Winterization: In areas subject to freezing temperatures, drain the pump completely and store it in a warm, dry place or ensure it is protected from frost.
- Professional Service: For complex issues or internal component replacement, contact a qualified service technician.
7. Troubleshooting
This section provides solutions for common issues. For problems not listed, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; tripped circuit breaker; motor overload; seized impeller. | Check power supply and connections; reset breaker; allow motor to cool; inspect impeller for obstructions. |
| Pump runs but no water flow | Pump not primed; air leak in suction line; clogged suction strainer; low water level at source. | Re-prime the pump; check all suction connections for leaks; clean strainer; ensure adequate water supply. |
| Reduced flow or pressure | Partial blockage in piping; worn impeller; air in system; incorrect pipe size. | Inspect and clear blockages; check for air leaks; consult a professional for impeller inspection. |
| Excessive noise or vibration | Cavitation (air in pump); loose mounting; bearing wear; foreign object in pump. | Ensure pump is fully primed and no air leaks; tighten mounting bolts; contact service for bearing issues; inspect for debris. |
8. Technical Specifications
| Attribute | Value |
|---|---|
| Brand | Pedrollo |
| Model | 3CRm100-N |
| Pump Style | Centrifugal, Horizontal Multistage |
| Power Source | AC/DC (115V/60Hz, 0.75HP) |
| Liquid Type | Clean water |
| Liquid Temperature Range | -10 °C to +40 °C |
| Ambient Temperature | Up to +40 °C |
| Manometric Suction Lift | Up to 7 m |
| Max. Working Pressure | 7 bar |
| Continuous Service | S1 |
| Connections | NPT Threaded |
| UPC | 722777873594 |
| ASIN | B09HL5N9WW |
9. Warranty and Support
For warranty information, technical support, or to purchase replacement parts, please contact Pedrollo customer service or visit their official website. Keep your purchase receipt as proof of purchase for warranty claims.
For further assistance, you may refer to the product page on Amazon: Product Link