Introduction
This manual provides essential information for the installation, operation, and maintenance of the BFT PHOBOS BT KIT A25 electromechanical operator for swing gates. This kit is designed to automate swing gates weighing up to 400 kg and with a leaf length of up to 2.5 meters. The complete set includes two irreversible 24V electromechanical operators suitable for gates up to 250 kg in weight and 5 meters in length (total for both leaves).
Please read this manual carefully before proceeding with installation or operation to ensure safe and correct use of the product.
Safety Information
WARNING: Improper installation or use can cause serious injury or damage.
- Installation must be performed by qualified personnel in compliance with local regulations and safety standards.
- Disconnect power before performing any maintenance or repair work.
- Ensure all electrical connections are properly insulated and grounded.
- Do not allow children to play near the gate or operate the controls.
- Keep remote controls out of reach of children.
- Regularly inspect the system for signs of wear or damage.
Product Overview
The BFT PHOBOS BT KIT A25 includes the following main components:
- Two 24V irreversible electromechanical operators for swing gates.
- Control unit (housed in a protective box).
- Remote controls.
- Safety photocells.
- Warning light.
- Key release mechanism for manual operation.

Figure 1: Overview of the BFT PHOBOS BT KIT A25 components. This image displays the two linear gate operators, the central control unit within its housing, two remote controls, a pair of safety photocells, a warning light, and a manual key release mechanism. These are the primary elements included in the gate automation kit.
Setup and Installation
Installation of the BFT PHOBOS BT KIT A25 requires careful attention to mechanical mounting and electrical wiring. It is highly recommended that installation be carried out by a professional installer.
Mechanical Installation
- Mounting the Operators: Securely attach the two electromechanical operators to the gate posts and gate leaves using appropriate brackets and fasteners. Ensure correct alignment for smooth gate movement.
- Photocell Placement: Install the safety photocells at a suitable height and position to detect obstacles in the gate's path. Ensure they are aligned correctly.
- Warning Light: Mount the warning light in a visible location to indicate gate movement.
Electrical Connections
- Power Supply: Connect the main power supply to the control unit, ensuring it is a 24V supply as specified.
- Motor Connections: Connect the motor cables from each operator to the designated terminals on the control unit.
- Accessory Connections: Wire the photocells, warning light, and any other accessories (e.g., key switch, intercom) to the control unit according to the wiring diagram provided in the detailed product manual (not included here).
- Grounding: Ensure all components are properly grounded to prevent electrical hazards.
Initial Programming
After mechanical and electrical installation, the control unit will require initial programming to set gate travel limits, operating speeds, and safety features. Refer to the specific programming instructions provided with the control unit for detailed steps.
Operating Instructions
Remote Control Operation
The gate can be operated using the provided remote controls. Pressing a programmed button on the remote will initiate the gate's movement (open/close cycle). A second press typically stops the gate, and a third press reverses its direction.
Manual Override
In case of power failure or system malfunction, the gate can be operated manually using the key release mechanism. Insert the key into the lock on the operator and turn it to disengage the motor, allowing the gate to be moved by hand.
CAUTION: Always ensure the gate area is clear before operating, especially during manual override.
Maintenance
Regular maintenance ensures the longevity and safe operation of your BFT gate opener system.
- Monthly Inspection: Check the gate's movement for any unusual noises or resistance. Ensure all mounting bolts are tight.
- Photocell Cleaning: Keep the photocell lenses clean and free from dirt, dust, or spiderwebs to ensure proper function.
- Lubrication: Periodically lubricate moving parts of the gate hinges and operator mechanism as recommended by the detailed product manual.
- Electrical Check: Annually, have a qualified technician inspect electrical connections and system performance.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Gate does not move. | No power; remote control battery dead; safety photocells obstructed. | Check power supply; replace remote battery; clear photocell path. |
| Gate stops unexpectedly. | Obstruction detected by safety features; motor overheating. | Remove obstruction; allow motor to cool down. |
| Remote control not working. | Battery low/dead; remote out of range; remote not programmed. | Replace battery; move closer to gate; re-program remote. |
For complex issues or if the problem persists, contact a qualified BFT service technician.
Specifications
| Attribute | Detail |
|---|---|
| Brand | BFT |
| Model Number | R935306 00004 |
| Product Dimensions | 10 x 30 x 30 cm (approximate for main components) |
| Item Weight | 11 Kilograms (total kit) |
| Power Supply | 24 Volt |
| Gate Weight Capacity | Up to 400 kg (total for swing gates) |
| Gate Length Capacity | Up to 2.5 m per leaf (5 m total for two leaves) |
| Color | Nd (No specific color indicated, likely neutral/standard) |
| First Available Date | September 12, 2016 |
Warranty and Support
For warranty information, please refer to the documentation provided with your purchase or contact BFT customer service directly. BFT products typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, spare parts, or professional assistance with installation and maintenance, please contact your authorized BFT dealer or visit the official BFT website for contact details.
BFT Official Website: www.bftautomation.com