PHOBOS BT KIT ULUULLUL QUICK REFERENCE GUIDE

6 Technical Support: 1-877-995-8155 • Disengage operator with manual release key (E). Disengage operator with manual release key (E). • Position the gate in closed position as shown in Fig. 3.

PDF preview unavailable. Download the PDF instead.

PHOBOS N BT - 24V - SWING OPERATOR - MANUAL - QUICK REFERENCE - 2
PHOBOS BT KIT UL QUICK REFERENCE GUIDE
· Read and follow all instructions and safety procedures. · Never let play on or walk in the automatic gate area. · Keep all gate controls out of the reach of children. · Stand clear of a moving gate and never cross the path of a moving gate. · All wiring should only be done by a qualified technician. · Always make adjustments and connections with supply power turned "off". · This document does not supersede the full instruction manual included with
each product.
BFT U.S., Inc. 6100 Broken Sound Pkwy., N.W. Suite 14 Boca Raton, FL 33487, U.S.A. T US: 1 877-995-8155, T: +1 561-995-8155, F: +1 561-995-8160, www.bft-usa.com, info.bft@bft-usa.com

TABLE OF CONTENTS

PHOBOS BT Kit Components Technical Specifications Spare Parts Accessories and Replacement Parts Brackets Installation (Pull to Open) Limit Switch Setting (Pull to Open) Brackets Installation (Push to Open) Limit Switch Setting (Push to Open) Wiring Instructions Battery backup installation Control Board Quick Programming Menu Flow Chart Wiring Diagram Troubleshooting Notes

...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ...................................... ......................................

3 3 4 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19

2

Technical Support: 1-877-995-8155

THE PHOBOS BT KITS CONTAIN THE FOLLOWING COMPONENTS

A

B

C

H

I

Components
A. POST MOUNTING BRACKET B. GATE MOUNTING BRACKET C. BRACKET PIN D. PIN RETAINER CLIP E. MANUAL RELEASE KEY - CLS F. SHAFT COVER ACCESSORIES G. TRANSMITTER - MITTO 2 H. PHOTOCELLS - FL 130B I. RECEIVER ANTENNA - AEL 133 J. SHAFT COVER - CPH K. CONTROL BOARD - LIBRA UL R L. OPERATOR - PHOBOS BT

Technical Specifications:
Power supply: Working force: Working stroke: Piston travel speed Limit switches Manual operation: Cycles per day: Gate length: Gate weight:

D

E

F

G

J

K

L

Single Kit

Dual Kit

(Ref. # R935246 00002) (Ref. # R935246 00003)

1

2

1

2

2

4

2

4

1

2

1

2

2

2

1

1

1

1

1

2

1

1

1

2

120 V ac ± 10% - 60 Hz

450 lbs

11"

0.55''/s

Incorporated (magnetic)

Release key

60

6'

-

10'

550 lbs -

220 lbs

Technical Support: 1-877-995-8155

3

PHOBOS BT SPARE PARTS, ACCESSORIES AND REPLACEMENT PARTS

1 I099806 2 I099806 3 I099821 4 I099815 4 I099821 5 I099821 6 I099819 6 I099821 7 I099821 8 I099820 9 D221830 11 I099821 12 I099805 12 I099819 13 I099804

13 I099804 14 I099805 15 I099804 16 I099821 17 I099805 18 I099805 19 I099822 20 I099821 21 I099821 22 N733264 23 I099822 24 I099805 25 I099819 26 I099806 27 I099806

REPLACEMENT PARTS
Item · OPERATOR ­ PHOBOS BT · CONTROL BOARD - LIBRA UL R · TRANSMITTER - MITTO 2 · PHOTOCELLS - FL 130B · RECEIVER ANTENNA - AEL 433 · MANUAL RELEASE KEY - CLS · SHAFT COVER - CPH

4

SPARE PARTS

28 I099806 29 I099822 30 I099817 31 I099823 32 I099823 33 I099820 34 D161511 35 I099824 36 I099824 37 I099805 38 I099804 38 I099820 39 I099821 40 D221931 41 I099805

41 I099821 42 I099805 42 I099819 43 I099805 44 I099806 45 I099824 46 I099824 47 I099824 48 I099805 49 I099804 50 I099805 51 D221829 52 I099820 53 I099824 54 I099824

55 I099819 55 I099824 56 I099824 57 I099804 58 I099804 59 I099804 60 I099804 60 I099819 61 I099820 62 I099820 63 I099821 64 I099826 65 I099826 66 I099826 67 I099805

68 I099826 69 I099825 70 I099825 71 I099825 72 I099825 78 I101116 82 I101111 83 I101115

Ref. # P935069 00001 D113701 00001
D111750 P111043 00001
D113632 D610180 P135004

OPTIONAL ACCESSORIES
Item · ADJUSTABLE POST BRACKET - SFR · BOLTABLE ANCHOR PLATE FOR
POST BRACKET- PPE · DIGITAL KEYPAD (external)- SELETTO E · DIGITAL KEYPAD (flush)- SELETTO · INTERFACE FOR SELETTO - SCS · VERTICAL SOLENOID LOCK - ECB · LEFT HAND SOLENOID LOCK - ECB SX · RIGHT HAND SOLENOID LOCK - ECB DX · ECB LOCK INTERFACE - ME BT · 24 Vdc BATTERY BACKUP
Technical Support: 1-877-995-8155

Ref. # N733286 D730567
P121013 P121012 P111323 D121018 D121017 D121016 D111761 P125005

BRACKETS INSTALLATION (PULL TO OPEN)

· Inspect all components of the gate to insure proper operation. · Gate must swing freely throughout its travel.

STEP 1 Position the post mounting bracket (A) and gate mounting bracket (B) using the measurements of Fig. 1 for an open to inside 90° swing application and Fig. 2 for an open to inside 110° swing application. Secure by welding (or bolting if PPE or SFR used) (bracket A only).

5" ½ POST 5" ½
A ­ POST MOUNTING BRACKET

B ­ GATE MOUNTING BRACKET
GATE
39"
L ­ PHOBOS BT OPERATOR

4" ¾
POST 4" ¾
A ­ POST MOUNTING BRACKET

B ­ GATE MOUNTING BRACKET
GATE
39"
L ­ PHOBOS BT OPERATOR

FIG. 1

OPEN TO INSIDE UP TO 90° SWING (PULL TO OPEN)

FIG. 2

OPEN TO INSIDE UP TO 110° SWING (PULL TO OPEN)

STEP 2
Position the gate mounting bracket (B) so that the distance between the post and gate bracket rotation points is 39" (pull to open) with the gate closed. Secure by welding or bolting. Note: Do not mount bracket (B) on vertical pickets - weld a plate or bar horizontally across several pickets for reinforcement. Be sure to install brackets in a position to insure a level actuator arm.
STEP 3
Install the PHOBOS BT operator (L) on the mounting brackets and secure with bracket pins (C) and pin retainer clips (D) provided.
STEP 4
Mount the LIBRA UL R control box in close proximity to the PHOBOS BT actuator arm in accordance with local electrical regulations.

Technical Support: 1-877-995-8155

5

LIMIT SWITCH SETTING (PULL TO OPEN)

FIG. 3

FULLY CLOSED

LIMIT SWITCH

FIG. 4

FULLY OPEN

14" ½

14" ¾

LIMIT SWITCH

ADJUSTMENT OF THE EXTENDING LIMIT SENSOR

ADJUSTMENT OF THE RECTRACTING LIMIT SENSOR

· Disengage operator with manual release key (E). · Position the gate in closed position as shown in Fig. 3. · Locate the limit sensors located within the black track on the bottom of the PHOBOS BT arm as
shown in Fig. 3 and 4. · Loosen the screws on the limit sensor at the end of the arm, closest to the gate bracket (B). · Slide the limit sensor until the outside screw of the limit sensor is 14'' ½ from the center of the
gate bracket as shown in Fig. 3. Tighten the screws on limit sensor. · Move the gate to fully open position so the arm is retracted as shown in Fig. 4. · Loosen the screws on the limit sensor closest to the motor. · Slide the limit sensor nearest to the motor so the center of the gate mounting bracket (B) and
nearest limit sensor adjustment screw equals 14" 3/4 as shown in Fig. 4. Tighten the screws on limit sensor. · Push the gate to the closed position, assuring smooth and even operation. · Re-engage the operator with the manual release key (E).

6

Technical Support: 1-877-995-8155

BRACKETS INSTALLATION (PUSH TO OPEN)

STEP 1 Position the post mounting bracket (not provided) and gate mounting bracket (B) using the measurements of Fig. 5 for a push to open 90° swing application and Fig. 6 for a push to open 110° swing application. Secure by welding or bolting.

OPEN TO OUTSIDE UP TO 90° SWING (PUSH TO OPEN)

5" ½
POST MOUNTING BRACKET
FIG. 5

B ­ GATE MOUNTING BRACKET
L ­ PHOBOS BT OPERATOR
3"

28" ¼ 5" ½

POST MOUNTING BRACKET
FIG. 6

B ­ GATE MOUNTING BRACKET
L ­ PHOBOS BT OPERATOR
28" ¼ 6" ¾

STEP 2
Position the gate mounting bracket (B) so that the distance between the post and gate bracket rotation points is 28" ¼ (push to open) with the gate closed. Secure by welding or bolting. Note: Do not mount bracket on vertical pickets - weld a plate or bar horizontally across several pickets for reinforcement. Be sure to install brackets in a position to insure a level actuator arm.
STEP 3
Install the PHOBOS BT operator (L) on the mounting brackets and secure with bracket pins (C) and pin retainer clips (D) provided.
STEP 4
Mount the LIBRA UL R control box in close proximity to the PHOBOS BT actuator arm in accordance with local electrical regulations.

Technical Support: 1-877-995-8155

7

LIMIT SWITCH SETTING (PUSH TO OPEN)

FIG. 7

FULLY CLOSED

FIG. 8

FULLY OPEN
14" ½

LIMIT SWITCH

LIMIT SWITCH

14" ¾ ADJUSTMENT OF THE EXTENDING LIMIT SENSOR

ADJUSTMENT OF THE RECTRACTING LIMIT SENSOR

· Disengage operator with the manual release key (E). · Position the gate in closed position as shown in Fig. 7. · Locate the limit sensors located within the black track on the bottom of the PHOBOS BT arm as
shown in Fig. 7 and 8. · Loosen the screws on the limit sensor closest to motor. · Slide the limit sensor nearest to the motor so the center of the gate mounting bracket (B) and
nearest limit sensor adjustment screw equals 14 3/4" as shown in Fig. 7. Tighten screws on limit sensor. · Move the gate to fully open position so the arm is extended as shown in Fig. 8. · Loosen the screws on the limit sensor at the end of the arm, closest to gate bracket (B). · Slide the limit sensor until the outside screw of the limit sensor is 14''½ from the center of the gate bracket as shown in Fig. 8. Tighten the screws on limit sensor. · Push the gate to the closed position, assuring smooth & even operation. · Re-engage operator with manual release key (E).

8

Technical Support: 1-877-995-8155

WIRING INSTRUCTIONS

red black white

black red white

SINGLE OPERATOR INSTALLATION:
PULL TO OPEN
· Connect the red (+) wire of the Phobos actuator arm to terminal 3 of the Libra control board.
· Connect the black (-) wire of the Phobos actuator arm to terminal 4 of the Libra control board.
· Connect the white (FC) wire of the Phobos actuator arm to terminal 5 of the Libra control board.
PUSH TO OPEN
· Connect the red (+) wire of the Phobos actuator arm to terminal 4 of the Libra control board.
· Connect the black (-) wire of the Phobos actuator arm to terminal 3 of the Libra control board.
· Connect the white (FC) wire of the Phobos actuator arm to terminal 5 of the Libra control board.
DUAL OPERATOR INSTALLATION:
PULL TO OPEN
· Connect the red (+) wire of the Phobos actuator arm to terminal 6 of the Libra control board.
· Connect the black (-) wire of the Phobos actuator arm to terminal 7 of the Libra control board.
· Connect the white (FC) wire of the Phobos actuator arm to terminal 8 of the Libra control board.
PUSH TO OPEN
· Connect the red (+) wire of the Phobos actuator arm to terminal 7 of the Libra control board.
· Connect the black (-) wire of the Phobos actuator arm to terminal 6 of the Libra control board.
· Connect the white (FC) wire of the Phobos actuator arm to terminal 8 of the Libra control board.

Technical Support: 1-877-995-8155

9

red black white red black white

black red white black red white

WIRING INSTRUCTIONS

CONNECTING THE POWER:
· Connect the line wire of the 110 volt power source to terminal L of the Libra control board.
· Connect the neutral wire of the 110 volt power source to terminal N of the Libra control board.
· Connect the ground wire of the 110 volt power source to ground terminal of the Libra control board.
Wire not supplied
CONNECTING THE ANTENNA:
· Connect the antenna cable to the Libra circuit board. Strip cable and connect the core wire to terminal 23 and the shield wire to terminal 24.

ground (green) line (black) neutral (white)

shield core

CONNECTING THE PHOTOEYE (THROUGH BEAM):
· Connect #1 & #2 of the photoeye receiver to the terminal 11 & 12 of the Libra control board.
· Connect #3 & #5 of the photoeye receiver to the terminal 15 & 18 of the Libra control board. Remove jumper wire.

Wires not supplied.

· Connect #1 & #2 of the photocell transmitter to the terminal 11 & 12 of the Libra control board.
Wires not supplied.

10

Technical Support: 1-877-995-8155

WIRING INSTRUCTIONS

· Note: on BFT control boards safety contacts are always N.C., multiple safety devices connected to the same contact have to be connected in series. Command contacts are always N.O.; multiple command devices connected to the same contact have to be connected in parallel. CAUTION: All command and safety contacts are dry contacts, giving tension to these contacts will damage the board.
· In case more than one photoeye is required, photoeyes have to be connected in series (NC contact). Follow the diagram (install receivers to avoid cross talking):

BFT Photoeye Receiver 1

BFT Photoeye Receiver 2

LIBRA UL R

BFT Photoeye Transmitter 1

BFT Photoeye Transmitter 2

CONNECTING THE SAFETY LOOPS:
· Safety loops detectors have to be connected as photoeyes, as they use the same PHOT contact (15 ­ 18). Every device connected to PHOT contact, including the safety loops, has to be a N.C. contact and will be connected in series.

CONNECTING OTHER ACCESSORIES:
· Accessories such as telephone entry systems and free exit loops will be connected to the OPEN contact (15 ­ 20). Every device connected to OPEN contact has to be a N.O. contact and will be connected in parallel.
· Accessories such as Single Button Control or external receiver contact will be connected to the START contact (15 ­ 16). The button will command the gate to: OPEN/STOP/CLOSE in sequence (3 step logic ON) OPEN/STOP/CLOSE/STOP in sequence (3 step logic OFF) Note: START-CLOSE logic has to be set to OFF for the Single Button Control to work correctly. For further details on programming the control board, refer to "Finalizing the installation" chapter at page 13.

Technical Support: 1-877-995-8155

11

BATERY BACKUP INSTALLATION
· Unplug the power. · Cut wire going from JP2 connector on the board to 0V connector on the transformer. Strip
resulting ends. Cut wire going from JP5 connector to 25V connector on the transformer. Strip resulting ends. · Using a wire nut (not supplied) connect JP2, 0V and an additional wire (not supplied) together. Connect other end of this additional wire on terminal # 3 on the SBS charger board. · Using a wire nut (not supplied), connect together transformer 25V wire and an additional wire (not supplied). Connect other end of this additional wire to terminal # 4 on the SBS charger. · Using a wire nut (not supplied), connect together JP5 wire and an additional wire (not supplied). Connect other end of this additional wire to terminal # 5 on the SBS charger. · Connect the batteries to terminal # 1 & 2 on the SBS charger as illustrated below.
0V

0V

JP5

Feed JP2

25V 0V

Black

Red

SBS

Feed
25V 0V Battery Battery +

· Check that polarity is respected with photocells and accessory power supply: When in battery mode #11 is + (positive), #12 is ­ (negative).

· On BFT photocells #1 is + (positive), #2 is ­ (negative):

(-) 12

(+) 11

· Check other accessories polarity according to the manufacturer's installation manual.

12

Technical Support: 1-877-995-8155

2 (-) 1 (+)
5 4 3
2 (-) 1 (+)

CONTROL BOARD QUICK PROGRAMMING

NAVIGATING THROUGH THE MENUS:

+ BUTTON - BUTTON

OK BUTTON

· The "OK" button is used for: switching on the display, confirming changes to the programming, entering the menus.
· The "+" button is used for: scrolling up the menus (go up in the menus as shown at page 15), increasing values.
· The "-" button is used for: scrolling down the menus (go down in the menus as shown at page 15), decreasing values.
· The "+" and "-" buttons pushed at the same time are used for: getting back one level in the menus, discarding changes to programming, exiting from the programming mode (turning off the display).

FINALIZING THE INSTALLATION:
· Turn the power off to the control board. · Connect any external control device according to wiring diagram on page 17. · Turn on power to control board. Check red power light on Libra control board.
ADDING TRASMITTERS TO THE RECEIVER 1. Turn on the display (by pressing twice the "OK" button). 2. Scroll down ("-" button) to "Radio" menu and press "OK". 3. The display will show "Add Start". Press "OK". 4. The display will show "Hidden button". Press the hidden button of the transmitter you want to store as shown in Fig. 9. 5. The display will show "Desired button". Press the button you want to activate the gate with as shown in Fig. 10. 6. The display will show "Add Start", repeat the procedure from step # 3 to install other transmitters. 7. Switch off the display by pressing "+" and "-" buttons at the same time twice.

FIG. 9 FIG. 10

Technical Support: 1-877-995-8155

13

CONTROL BOARD QUICK PROGRAMMING

SINGLE OPERATOR SETTING Only when installing a single actuator (skip in case of dual operator installation): 1. Turn on the display (by pressing twice the "OK" button). 2. Scroll down ("-" button) to "Logic" menu and press "OK". 3. The display will show "Tca". Scroll down to "1 Mot on". Press "OK". 4. The display will show "Off". Press "+". 5. The display will show "On". Press "OK" . 6. Switch of the display. Warning: when installing a single operator, a wrong setting in this logic will lead to wrong function of auto-close feature.
SETTING THE FORCE 1. Turn on the display (by pressing twice the "OK" button). 2. Scroll down ("-" button) to "Autoset" menu. The Autoset feature will automatically let the control board learn torques required to correctly operate the gate.

WARNING: Once "OK" button is pressed the gate will start to move, obstruction detection is disabled during Autoset. Be sure that no obstacle is within the working range of the gate while Autoset is being performed.

NOTE: the Autoset must be launched from a fully closed position. Autoset run from a different position may lead to improper control board setting.
3. Press "OK". The gate will open and close automatically.
4. Once the gate is closed the display will show "OK" (Autoset successful) press "OK" (if "KO" is displayed, the Autoset failed, usually the cause of it is an improper setting for single operator installation).
5. Turn off the display.

COMMON SETTINGS

Parameters: TCA: M1 fast time:

Timer to close (sec.). Working time (sec) at full speed (motor 1) after this time motor 1 will proceed at slow down speed).

M2 fast time: Working time (sec) at full speed (motor 2) after this time motor 2 will proceed at slow down speed.

Slow speed: Slow down speed: 3 (25% of full speed)

WARNING! after changing the above parameters (except TCA) an Autoset is required.

Logics:

TCA:

Auto close enabled (ON)

3 step:

3 step logic (ON)

Ibl open:

Commands during opening ignored (ON).

Photoc. Open: Photocells will be ignored while the gate is opening (ON)

1 mot on:

Dual operator installation (OFF), single operator installation (ON).

14

Technical Support: 1-877-995-8155

MENU FLOW CHART

Technical Support: 1-877-995-8155

PARAMETER MENU TCA (timer to close) [sec.] (default 10 sec., min 3 sec., max 60 sec.) Motor 1 torque [%] (default 50%, min 1%, max 99%) Motor 2 torque [%] (default 50%. min 1%, max 99%) Motor 1 torque slow-down [%] (default 5%, min 1%, max 99%) Motor 2 torque slow-down [%] (default 5%, min 1%, max 99%) Opening delay time [tenths of a sec.] default 10 = 1 sec., min 10 = 1 sec., max 100 = 10 sec.) Closing delay time [tenths of a sec.] (default 10 = 1 sec., min 10 = 1 sec., max 100 = 10 sec.) Motor 1 normal speed time [sec.] (default 15 sec., min 1sec., max 30 sec.) Motor 2 normal speed time [sec.] (default 15 sec., min 1sec., max 30 sec.) Slow-down speed
0= Slow-down disabled 1 = 50% of normal speed 2= 33% of normal speed 3= 25% of normal speed Zone (serial connection ­ requires SCS card) (default 0, min 0, max 127)
LOGIC MENU TCA (automatic closing) Default: OFF, Enabled: ON, Disabled: OFF 3 STEP (3 step/4 step) Default: OFF, 3 step: ON, 4 step: OFF IBL OPEN (commands ignored on opening) Default: OFF, Enabled: ON, Disabled: OFF FAST CLS (closing on photoeye disengage) Default: OFF, Enabled: ON, Disabled: OFF PHOTOC. OPEN (photoeye ignored on opening) Default: OFF, Enabled: ON, Disabled: OFF TEST PHOT (photocell test ­ requires different wiring if ON, see instruction manual for further details) Default: OFF, Enabled: ON, Disabled: OFF 1 MOT ON (single operator installation) Default: OFF, Single op. install.: ON, Dual op. inst.: OFF BLOC PERSIST (lock hold - use only if positive stops installed) Default: OFF, Enabled: ON, Disabled: OFF START-CLOSE (terminal 16 as CLOSE) Default: OFF, Term. 16: CLOSE: ON, Term. 16 START: OFF FIXED CODE (fixed/rolling code receiver) Default:ON, Fixed code: ON, Rolling code: OFF RADIO PROG. (radio learn) Default: ON, Enabled: ON, Disabled: OFF MASTER (the board is a "master board" ­ requires SCS card) Default: OFF, Master board: ON, Slave board: OFF
Warning: the logic MASTER has no relation to single/dual operator installation, it is used only if serial connection with multiple boards is required.
15

MENU FLOW CHART
RADIO MENU ADD START (Program a button of a remote to activate the gate) ADD 2CH (No effect) READ (Check if a remote is I the memory of the receiver and display button #) EX: 02 t1 (remote #2, button #1) ko (remote not in the memory) ERASE 64 WARNING! Removes all remotes devices from the receiver memory. COD RX Displays the receiver code (required only if cloning remotes is needed)

AUTOSET It automatically sets the motor torque (Motor 1 torque, Motor 2 torque, Motor 1 slow down torque, Motor 2 slow down torque).
Note: If slow down is disabled or not reached slow down torque will not be set. After slow down adjustment Autoset has to be carried out gain.
WARNING! obstruction detection is disabled during Autoset. Be sure that no obstacle is within the working range of the gate while Autoset is being performed.

16

Technical Support: 1-877-995-8155

WIRING DIAGRAM

L N
24 Vdc/25 W max 24 Vac OUT (180 mA max) 24 Vac Vsafe OUT (180 mA max)
Note: while the alarm is active the gate is stopped. Reset the
control board before reactivating the gate.

LINE (BLACK) NEUTRAL (WHITE)

RED BLACK WHITE
RED BLACK WHITE

MOTOR 2 MOTOR 1

Single operator or operator that moves first on opening.
Operator that moves second on opening.

STROBE LIGHT CONNECTION

24 Vac power supply to accessories
24 Vac power supply to fail safe accessories (requires different wiring ­ see instruction manual for further details)
COMMON TEMINAL
START/CLOSE TEMINAL: opens-closes-stops (START) or always closes (CLOSE) the gate depending on the logic setting (default is START)
STOP & RESET TERMINAL: stops the gate and UL ALARM when opened PHOTOEYE TERMINAL: stops the gate when opened, when closed back continues opening (if gate opening) or reverses (if gate closing) PHOTOEYE SELF TEST TERMINAL: failure check terminal for PHOTOEYE terminal (requires different wiring ­ see instruction manual for dOePtEaNilsT)ERMINAL: opens the gate when closed (e.g. free exit or telephone entry contact)
UL ALARM: the contact closes after 2 consecutive obstruction detections with no limit switch activation. Can be reset by opening the stop contact or switching off the power supply.

Technical Support: 1-877-995-8155

17

TROUBLESHOOTING

FAULT
The red LED on the left of the display is OFF
OPERATOR DOES NOT RUN remote or single button control (terminal 15-16) not working. No relay clicking audible.
OPERATOR DOES NOT RUN Relay clicking audible
GATE OPENS BUT DOESN'T CLOSE
GATE STOPS AND REVERSES AFTER STRTING TO MOVE
GATE DOES NOT CLOSE AUTOMATICALLY
GATE RUNS TOO SLOW
GATE DOES NOT SLOW DOWN

DIAGNOSTIC
STOP PHOT Display blank and STRT displayed when hitting the button STRT not displayed when hitting the button
STRT displayed when giving the command
OPEN PHOT AMP displayed when starting reversing
00.XX OPEN PHOT

POSSIBLE CAUSE
Power or transformer connection is loose.
Main fuse (next to transformer primary) is blown. Bad control board. STOP contact is open (15 ­ 17). PHOT contact is open (15 ­ 18).
UL ALARM activated (21 ­ 22 contact closed).
Remote not programmed.
Remote battery out of charge (LED off on the remote when pressing button). Motor fuse blown. Bad control board. Wrong connection of the motor wires.
Bad control board. Bad motor. OPEN contact (15-20) continuously closed (ex. open button stuck). PHOT contact is open (15 ­ 18). The gate opens because photoeye is ignored on opening in the logic setting. Torque setting too low.
Obstruction present. Automatic closing is disabled.
In a single operator installation, dual operator installation has been set. OPEN contact (15-20) continuously closed (ex. open button stuck). PHOT contact is open (15 ­ 18). The gate opens because photoeye is ignored on opening in the logic setting. Working time at normal speed is set too low.
Slow down is disabled.
Working time at normal speed is higher than the time required getting to the full opening/closing position.

FIX
Check power and transformer connections. Replace fuse.
Replace control board.
Check STOP contact connections. Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices. Reset the board (open and close STOP contact (15 - 17) or switch off and back on the power. Program remote (see remote programming at page 13). Replace battery.
Replace fuse Replace control board.
Check that the white wire is connected to terminals # 5 (motor 2) and 8 (motor 1). Replace control board. Replace motor.
Open the OPEN contact.
Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices.
Increase manually the torque (Motor 1 torque, Motor 2 torque, Motor 1 torque slow-down, Motor 2 torque slow-down in parameters section) or un another Autoset. Remove obstructions.
Set automatic closing (TCA in logics section) to ON. Set single operator installation (1 MOT ON in logics section) to ON. Open the OPEN contact.
Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices.
Increase working time at normal speed (Motor 1 normal speed time, Motor 2 normal speed time in parameters section) to desired value.
Activate slow down (Slow-down speed in parameters section). Decrease working time at normal speed (Motor 1 normal speed time, Motor 2 normal speed time in parameters section) to desired value.

18

Technical Support: 1-877-995-8155

NOTES

Technical Support: 1-877-995-8155

19

PHOBOS BT

PHOBOS BT QUICK REFERENCE GUIDE v 1.2 - 01/10/2008

· UL 325 approved by CSA · LCD display programming for maximum installation speed and flexibility · Exhaustive diagnostic messages by the display · Built-in rolling code receiver · Quick install, only 3 wires from the operator housing to the control board (the
only UL approved motor with this feature) · The most energy efficient motor at only 40 W (1.6 amps) · Autoset feature to quickly and simply adjust torque level on the gate · Dual and single installation with the same control board · Opening angle up to 120° · Adjustable slow down, 3 different slowdown speeds · Battery backup available, batteries are engaged only when main power is out · Easy manual release through triangular key · Inherent obstruction detection system for maximum safety · Overlapping gates management