1. Product Overview

The AMT 368C-95 is a .75" x .5" Cast Iron Straight Centrifugal Pump, featuring a Buna-N Seal and a 1/2hp 3 Phase Motor. It is designed for continuous-duty low pressure OEM, industrial/commercial, and general service applications.

Key features include:

  • Designed for continuous-duty low pressure OEM, Industrial/Commercial & General Service Applications
  • Applications including circulation, chemical processing, liquid transfer, dirty water and cooling
  • Pull-from-rear design for easy service without disturbing any piping; Self-Cleaning Impeller
  • Pumps are close coupled to TEFC motors; Pumps are NOT self-priming & require flooded suction
  • Cast Iron with SS, Self-Cleaning Impeller; Discharge Rotates in 90 Degree Increments
AMT 368C-95 Centrifugal Pump

Figure 1: The AMT 368C-95 Cast Iron Straight Centrifugal Pump. This image shows the pump assembly with its motor, cast iron housing, and the inlet/outlet ports.

2. Safety Information

Legal Disclaimer:

This item, component, package or system is intended for professional use only, by persons knowledgeable of how to determine if it is chemically compatible with the liquid(s) to be pumped, the safe installation, use and maintenance of pressure-generating and pressure-containing devices and the safe installation, use and maintenance of electrically, pneumatically and hydraulically powered equipment.

Always ensure proper electrical grounding and adhere to local electrical codes. Disconnect power before performing any maintenance or service.

3. Setup and Installation

3.1. Site Preparation

Ensure the installation site is stable, level, and capable of supporting the pump's weight (approximately 31 pounds). Provide adequate ventilation for the motor.

3.2. Piping Connections

The pump features a .75" x .5" connection. Ensure all piping is properly sized and supported to prevent strain on the pump. The discharge can rotate in 90-degree increments for flexible installation.

3.3. Electrical Connection

This pump is equipped with a 1/2hp 3 Phase Motor, 230/460 VAC/60 Hz. Electric supply for ALL motors must be within +/-10% of nameplate voltage rating (e.g., 230V +/-10% = 207 to 253). Consult a qualified electrician for wiring. Ensure proper grounding.

3.4. Priming

Important: This pump is NOT self-priming and requires flooded suction. Ensure the pump casing and suction line are completely filled with liquid before starting the pump to prevent damage.

4. Operating Instructions

4.1. Pre-Operation Check

  • Verify all connections are secure and leak-free.
  • Confirm the pump is properly primed (flooded suction).
  • Ensure the power supply matches the motor's requirements.

4.2. Starting the Pump

Once all pre-operation checks are complete, apply power to the motor. The pump is designed for continuous-duty operation.

4.3. Applications

This pump is suitable for various applications including circulation, chemical processing, liquid transfer, dirty water, and cooling. The self-cleaning, semi-open, stainless steel impeller can handle solids up to 1/8" diameter.

Performance Curve of Straight Centrifugal Pumps

Figure 2: Performance curves for various straight centrifugal pumps, including the 368 series. This chart illustrates the relationship between total head (pressure) and capacity (flow rate) at 3450 RPM (60 Hz), along with Net Positive Suction Head Required (NPSHr) values.

5. Maintenance

5.1. Routine Checks

  • Regularly inspect for leaks around seals and connections.
  • Monitor motor temperature and unusual noises.
  • Check for any obstructions in the suction or discharge lines.

5.2. Impeller and Seal Service

The pump features a "pull-from-rear" design, allowing for easy service of the impeller and mechanical seal without disturbing the piping. The self-cleaning impeller helps prevent clogging, but periodic inspection for debris is recommended, especially when pumping dirty water.

The pump uses a Buna-N Mechanical Seal and O-ring. Optional Silicon Carbide Mechanical Seals are available for different applications.

5.3. Winterization (if applicable)

If the pump is exposed to freezing temperatures, drain all liquid from the pump casing using the front drain plug to prevent damage from ice expansion.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, consult a qualified technician.

ProblemPossible CauseSolution
Pump not startingNo power, incorrect wiring, motor issueCheck power supply, verify wiring, consult electrician
Low flow or no flowPump not primed, clogged impeller/lines, air leak in suctionEnsure flooded suction, clear clogs, check suction line for leaks
Excessive noise or vibrationCavitation, bearing wear, misalignment, foreign object in pumpEnsure proper priming, inspect bearings, check alignment, clear pump
Leaking from sealWorn mechanical seal, improper installationReplace mechanical seal, ensure correct installation

7. Specifications

AttributeValue
Model368C-95
Product Dimensions12.4 x 8.3 x 7.2 inches
Item Weight31 Pounds
ManufacturerAmerican Machine and Tool Company
BrandUnknown
MaterialCast Iron
Seal TypeBuna-N Mechanical Seal and O-ring
Motor1/2hp 3 Phase TEFC
Voltage230/460 VAC/60 Hz
Maximum Flow Rate90 GPM (143.83 Liters Per Minute)
Maximum Head65 Ft
Maximum Working Pressure75 PSI
Maximum Temperature180 F
Solids HandlingUp to 1/8" diameter
Dimensional Drawing and Specifications Table for AMT Pumps

Figure 3: Detailed dimensional drawing of the pump and motor assembly, along with a table providing specific measurements (A, B, C, E, L, W, H) and weight for various AMT pump models, including the 368 series.

8. Warranty and Support

For warranty information and technical support, please contact the manufacturer, American Machine and Tool Company, or your authorized distributor. Keep your purchase receipt and product model number (368C-95) handy when contacting support.

Refer to the official product page or manufacturer's website for the most current warranty terms and contact details.

© 2024 AMT (American Machine and Tool Company). All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.