FS LC Simplex Fast Connector Instructions
Connector Instruction
- Insert the connector boot onto the cable
- Strip outer jacket about 50mm to reveal 900-micron fibers
- Using the label, measure from the end of the buffer and make a mark between the 250µm and 125µm section
- Strip the buffer to the mark using the middle hole, then the small hole on the stripper in short increments
- Cleave your fiber strand to 10mm from the mark
- Strip the remaining 20mm of buffer using the middle hole on the stripper
- Clean any impurities from your cable using alcohol and a lint-free cloth
- Insert the fiber into the connector body until the strand meets resistance and bows slightly
- Remove the connector jig
- Lock the fiber inside the connector by pressing the amber button
- Screw the boot onto the connector body and trim any exposed Kevlar yarn
- To remove or re-terminate the connector, simple unscrew the boot and replace the jig