SC-Simplex-LOGO

33sc-01020 Simplex Single Mode Fast Connector

SC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-PRODUCT

Specifications

  • Connector Type: Fiber Optic
  • Cable Compatibility: 900-micron fibers
  • Material: Plastic, Amber
  • Includes: Connector boot, Adapter tube, Stripper, Lint-freecloth

Product Usage Instructions

1. Preparation:

Insert the connector boot and adapter tube onto the cable. Strip the outer jacket about 50mm to reveal 900-micronfibers.

2. Stripping and Cleaning:

Measure from the end of the jacket and strip the remaining 20mm of buffer from the edge of the jacket using the middle hole on the stripper. Clean any impurities from your cable using alcohol and a lint-free cloth.

3. Fiber Insertion:

Insert the fiber into the connector body until the strand meets resistance and bows slightly.

4. Connector Assembly:

Remove the connector jig. Lock the fiber inside the connector by pressing the amber button. Slide the adapter tube into the connector, then screw the boot onto the connector body and trim any exposed Kevlar yarn.

5. Removal or Re-termination:

To remove or re-terminate the connector, simply unscrew the boot and replace the jig.

FAQs

Q: How do I clean impurities from the cable?

A: Use alcohol and a lint-free cloth to clean any impurities from your cable.

Q: What should I do if the fiber does not meet resistance when inserting it into the connector body?

A: Ensure that you are inserting the fiber correctly and contact customer support if issues persist.

INSTALLATION

  • Insert the connector boot and adapter tube onto the cableSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-1
  • Strip the outer jacket about 50mm to reveal 900-micron fibersSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-2
  • Measure from the end of the jacket and make a mark between the 250µm and 125µm sectionSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-3
  • Strip the buffer to the 250µm ma rk using the middle hole, then the small hole on the stripper in short incrementsSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-4
  • Cleave your fiber strand to 10mm from the 250µm measurement markSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-5
  • Strip the remaining 20mm of buffer from the edge of the jacket using the middle hole on the stripperSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-6
  • Clean any impurities from your cable using alcohol and a lint-free clothSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-7
  • Insert the fiber into the connector body until the strand meets resistance and bows slightlySC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-8
  • Remove the connector jigSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-9
  • Lock the fiber inside the connector by pressing the amber buttonSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-10
  • Slide the adapter tube into the connector, then screw the boot onto the connector body and trim any exposed Kevlar yarnSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-11
  • To remove or re-terminate the connector, simply unscrew the boot and replace the jigSC-Simplex-33sc-01020-Simplex-Single-Mode-Fast-Connector-FIG-12