ZKTeco B1 Series Palm and Fingerprint Multibiometric Installation Guide

B1 Series Palm and Fingerprint Multibiometric

Specifications:

  • Product: BioFace B1 Series
  • Version: 1.0
  • Installation: Indoor only
  • Power Supply: 12V DC
  • Network Connectivity: Ethernet
  • Default IP Address: 192.168.1.201
  • Subnet Mask: 255.255.255.0

Installation Guide:

Installation Environment:

  • Avoid installation near glass windows, direct sunlight, heat
    sources, and moisture/water/rain exposure.
  • Handle the device with care.
  • Avoid installation near sea or locations prone to metal
    oxidation.
  • Protect the device from lightning.
  • Device should only work in an acidic or alkaline environment
    briefly.

Device Wall Installation:

  1. Stick the wall-mounting template to the wall and drill holes
    according to the template.
  2. Insert the expansion tubes into the mounting holes.
  3. Attach the backplate on the wall using the wall mounting
    screws. Insert wire through the backplate before installation.
  4. Attach the terminal to the backplate and secure with a security
    screw.

Connection Instructions:

Refer to the provided diagram for connecting doorbell, exit
button, alarm, door sensor, smoke detector, power supply, RS485,
Wiegand, Ethernet, and lock relay.

FAQ:

Q: What should I do if the device is exposed to direct sunlight
for an extended period?

A: Avoid direct contact with sunlight for a long time. Ensure
the device is protected from moisture and handle with care.

Q: How do I change the IP address of the device?

A: Click COMM. > Ethernet > IP Address on the device,
input the new IP address and click OK.

Q: Can I install the device outdoors?

A: No, the device should be installed indoors only to ensure
proper functioning and longevity.

Q: What is the default IP address of the device?

A: The default IP address is 192.168.1.201 with a subnet mask of
255.255.255.0.

“`

Installation Guide
BioFace B1 Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.

Installation Environment
Please refer to the following recommendations for installation:

INSTALL INDOORS ONLY

AVOID INSTALLATION NEAR
GLASS WINDOWS

AVOID DIRECT SUNLIGHT
AND EXPOSURE

AVOID USE OF ANY HEAT SOURCE
NEAR THE DEVICE

Y Avoid direct contact to sunlight for a long time.

Y Protect the device from moisture, water, and rain.

Y Handle the device with care.

Y Ensure that the device is not installed near the sea or in other locations where metal oxidation and rust may develop if the device is exposed for an extended period.

Y Protect the device from lightning.

Y Ensure that the device only works in an acidic or alkaline environment briefly.

How to Install the Device on the wall?

Step 1: Stick the wall-mounting template to the wall and drill holes according to the wall-mounting template.

1

2

30mm
90°
6mm

1450mm

-1-

Step 2: Insert the expansion tubes into the mounting holes. Step 3: Attach the backplate on the wall using the wall mounting screws.
Note: Please insert the wire through the backplate before installation.
-2-

Step 4: Attach the terminal to the backplate.

Step 5: Attach the terminal to the backplate with a security screw.
-3-

Door Bell, Exit Button and Alarm Connection

-+ -+

Exit Button Bell Power
Door Bell Alarm

+

WD1 WD0 GND GND BELLBELL+ SEN BUT
AUX GND AL-

GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+

+

Alarm’s Power Switch

Door Sensor and Smoke Detection Connection

WD1

WD0

Door Sensor GND

GND

BELL-

BELL+

SEN

COM

BUT AUX

NO GND

Smoke Detector AL-

GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+

-4-

Power Connection

GND 12V

GND 12VDC

Recommended Power Supply: Y 12V ± 10%, at least 3000mA. Y To share the power with other devices, use a power
supply with higher current ratings.
RS485 and Wiegand Connection

WD1 WD0 GND GND BELLBELL+ SEN BUT
AUX GND AL-

GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+

Access Controller

485+
485- RS485 GND Reader

GND +12V WD1 WD0
Wiegand Reader

-5-

Ethernet Connection

RX-

RX+

1

TX-

2

3

4 5

RJ

45

6

PC

TX+

7 8

Default IP Address: 192.168.1.201 IP Address: 192.168.1.130

Subnet Mask: 255.255.255.0

Subnet Mask: 255.255.255.0

Click COMM. > Ethernet > IP Address on the device, input the IP address and click OK.

Lock Relay Connection

The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally opened at power on) is connected with “NO1” and “COM” terminals, and the NC LOCK (normally closed at power on) is connected with”NC1″and”COM”terminals. Take NC Lock as an example below:

Device not sharing power with the lock:

Device sharing power with the lock:

GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+

+

+

DC12V

+ FR107

Normally Closed Lock

GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+

+

FR107 +

Normally Closed Lock

GND +12V

GND +12V

+

+

DC12V -6-

DC12V

Download Center
Scan the QR Code to download the User Manual, Installation Guide and Quick Start Guide.
QR Code (Download Center)
-7-

ZKTeco Middle East, Bay Square, Building 1, Office 502 & 503, Business Bay, Dubai, UAE Phone : +971 4 3927 649 www.zkteco.me
Copyright © 2023 ZKTECO CO., LTD. All Rights Reserved.