B1 Series Palm and Fingerprint Multibiometric
“
Specifications:
- Product: BioFace B1 Series
- Version: 1.0
- Installation: Indoor only
- Power Supply: 12V DC
- Network Connectivity: Ethernet
- Default IP Address: 192.168.1.201
- Subnet Mask: 255.255.255.0
Installation Guide:
Installation Environment:
- Avoid installation near glass windows, direct sunlight, heat
sources, and moisture/water/rain exposure. - Handle the device with care.
- Avoid installation near sea or locations prone to metal
oxidation. - Protect the device from lightning.
- Device should only work in an acidic or alkaline environment
briefly.
Device Wall Installation:
- Stick the wall-mounting template to the wall and drill holes
according to the template. - Insert the expansion tubes into the mounting holes.
- Attach the backplate on the wall using the wall mounting
screws. Insert wire through the backplate before installation. - Attach the terminal to the backplate and secure with a security
screw.
Connection Instructions:
Refer to the provided diagram for connecting doorbell, exit
button, alarm, door sensor, smoke detector, power supply, RS485,
Wiegand, Ethernet, and lock relay.
FAQ:
Q: What should I do if the device is exposed to direct sunlight
for an extended period?
A: Avoid direct contact with sunlight for a long time. Ensure
the device is protected from moisture and handle with care.
Q: How do I change the IP address of the device?
A: Click COMM. > Ethernet > IP Address on the device,
input the new IP address and click OK.
Q: Can I install the device outdoors?
A: No, the device should be installed indoors only to ensure
proper functioning and longevity.
Q: What is the default IP address of the device?
A: The default IP address is 192.168.1.201 with a subnet mask of
255.255.255.0.
“`
Installation Guide
BioFace B1 Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Installation Environment
Please refer to the following recommendations for installation:
INSTALL INDOORS ONLY
AVOID INSTALLATION NEAR
GLASS WINDOWS
AVOID DIRECT SUNLIGHT
AND EXPOSURE
AVOID USE OF ANY HEAT SOURCE
NEAR THE DEVICE
Y Avoid direct contact to sunlight for a long time.
Y Protect the device from moisture, water, and rain.
Y Handle the device with care.
Y Ensure that the device is not installed near the sea or in other locations where metal oxidation and rust may develop if the device is exposed for an extended period.
Y Protect the device from lightning.
Y Ensure that the device only works in an acidic or alkaline environment briefly.
How to Install the Device on the wall?
Step 1: Stick the wall-mounting template to the wall and drill holes according to the wall-mounting template.
1
2
30mm
90°
6mm
1450mm
-1-
Step 2: Insert the expansion tubes into the mounting holes. Step 3: Attach the backplate on the wall using the wall mounting screws.
Note: Please insert the wire through the backplate before installation.
-2-
Step 4: Attach the terminal to the backplate.
Step 5: Attach the terminal to the backplate with a security screw.
-3-
Door Bell, Exit Button and Alarm Connection
–
-+ -+
Exit Button Bell Power
Door Bell Alarm
+
WD1 WD0 GND GND BELLBELL+ SEN BUT
AUX GND AL-
GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+
+
–
Alarm’s Power Switch
Door Sensor and Smoke Detection Connection
WD1
WD0
Door Sensor GND
GND
BELL-
BELL+
SEN
COM
BUT AUX
NO GND
Smoke Detector AL-
GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+
-4-
Power Connection
GND 12V
GND 12VDC
Recommended Power Supply: Y 12V ± 10%, at least 3000mA. Y To share the power with other devices, use a power
supply with higher current ratings.
RS485 and Wiegand Connection
WD1 WD0 GND GND BELLBELL+ SEN BUT
AUX GND AL-
GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+
Access Controller
485+
485- RS485 GND Reader
GND +12V WD1 WD0
Wiegand Reader
-5-
Ethernet Connection
RX-
RX+
1
TX-
2
3
4 5
RJ
45
6
PC
TX+
7 8
Default IP Address: 192.168.1.201 IP Address: 192.168.1.130
Subnet Mask: 255.255.255.0
Subnet Mask: 255.255.255.0
Click COMM. > Ethernet > IP Address on the device, input the IP address and click OK.
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally opened at power on) is connected with “NO1” and “COM” terminals, and the NC LOCK (normally closed at power on) is connected with”NC1″and”COM”terminals. Take NC Lock as an example below:
Device not sharing power with the lock:
Device sharing power with the lock:
GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+
+
–
+
DC12V
–
+ FR107
–
Normally Closed Lock
GND +12V ID1 ID0 485A 485B GND
NC
COM NO AL+
–
+
FR107 +
–
Normally Closed Lock
–
–
GND +12V
GND +12V
+
+
DC12V -6-
DC12V
Download Center
Scan the QR Code to download the User Manual, Installation Guide and Quick Start Guide.