TE-03 TH
Temperature and Humidity
Data Logger
User Manual
Product Introductions
ThermElc TE-03 TH is used for monitoring temperature and humidity of the sensitive goods during storage and transpo- rtation. After the recording is finished, the ThermElc TE-03 TH is connected to any USB port and automatically generates a PDF & CSV report with the temperature and humidity logging results. No additional software is required to read out the ThermElc TE-03 TH.
Main Feature
- Multiple use temperature & humidity logger
- External sensor and bracket
- Auto generates PDF reports
- Auto generates CSV reports
- Logging of 34560 points
- Recording Interval of 10 seconds to 99 hours
- No special device driver required
- Temperature and humidity over-limit alarm
Quick Start
Quick Start ThermElc TE-03 ETH
- Software Download
https://www.thermelc.com/pages/download
- Press start 3 seconds
- Measure Monitoring
- Read
USB - Report
Auto PDF. CSV Report Data & Graphic Comparison Available
- Helps
https://www.thermelc.com/pages/contact-us
Configuration of ThermElc TE-03 TH
The device can be configured using the free data managem- ent software.
1 | Time zone: | UTC |
2 | Temperature scales: | °C /°F |
3 | Screen display: | Always on/ Timed |
4 | Start delays: | 0/timed (30min default) |
5 | Start delays: | 0/ timed |
6 | Stop mode: | Press button/ disabled |
7 | Start mode: | Press button or Timed |
8 | Temperature and humidity over-limit alarm | |
9 | Alarm setting: | Upper Limit and Lower Limit |
140 | FDA Module: | To enable in settings |
Operation Functions
- Start Recording
Press and hold the START button for approximately 3sec.The OK light is on and the () or (WAIT) on screen indicates the logger is started.
- Mark
When the device is recording, press and hold the START bu- tton for more than 3sec, and the screen will switch to the “MARK” interface. The number of MARK’ will increase by one, indicating data was marked successfully. - Stop Recording
Press and hold the STOP button for more than 3sec until the STOP () symbol displays on the screen, indicating stopping recording successfully.
- Switch the display
Shortly press START button to switch to different display int- erface. The interfaces shown in sequence are respectively: Real-time Temperature > Real-time Humidity > LOG > MARK > Temperature Upper Limit > Temperature Lower Limit > Humidity Upper Limit > Humidity Lower Limit. - Get Report
Connect the data logger to PC via USB, and it will auto-gen- erate PDF and CSV reports.
LCD Display Descriptio
![]() |
Data logger is recording |
![]() |
Data logger has stopped recording |
WAIT | Data logger is in Start Delay status. |
![]() |
Temperature and Humidity is within the limited range |
![]() |
Measured value exceeds its upper limit |
![]() |
Measured value exceeds its lower limit |
Battery Replacement
Technical Support | Video Instruction |
![]() |
![]() |
https://thermelc.com/pages/support |
https://www.youtube.com/channel/UCVcVdaeDAISsSzAxqYYj_jw |
https://www.thermelc.com
sales@thermelc.com
+44 (0)207 1939 488
Documents / Resources
![]() |
ThermElc TE-03 ETH Temperature Humidity Data Logger [pdf] User Manual TE-03 ETH Temperature Humidity Data Logger, TE-03 ETH, Temperature Humidity Data Logger, Humidity Data Logger, Data, Logger, Logger TE-03 ETH |