IME IDM Configuration Software

Émbaran produk
- Product Name: IDM Configuration Software
- Vérsi Parangkat Lunak: 1.00.00
- Operating System Compatibility: Windows 10, Windows 7, etc.
Parentah Pamakéan Produk
- Pamasangan
- Download the IDM Configuration Software from the IME websitus.
- Jalankeun pamasangan file (.exe).
- Choose the language and click OK.
- Turutan pitunjuk dina layar pikeun ngarengsekeun prosés pamasangan.
- Modification of Software’s Language
- In the software’s home page, click on “Software configuration”.
- Pilih basa anu dipikahoyong.
- Click on Save to confirm the language change.
- Pilarian Alat
- In the software’s home page:
- Click on “Search Device”.
- The scan page is divided into two sections:
- A. Channel Settings
- B. Device Settings
- The scan page is divided into two sections:
- A. Channel Settings:
- Choose the correct communication protocol (Modbus RTU, Modbus TCP, M-bus).
- Choose the correct COM port.
- B. Device Settings:
- Verify and choose the correct Baud rate and Parity.
- Search in a specific range of addresses or choose all addresses.
syarat Sistim
- Hardware:
- Intel® Core 2 Duo or AMD® Athlon X2® processor
- 2GB RAM
- 320MB rohangan hard disk anu sayogi
- USB port for connection IDM Configurator
- Sistem operasi anu dirojong:
- Microsoft Windows XP (Professional) – Service Pack 3
- Microsoft Windows Vista – Service Pack 2
- Microsoft Windows 7 – Service Pack 3
- Microsoft Windows 10 – All Service Pack Installation and Display:
- dina Komputer
- Konsep dasar
- The IDM Configuration Software offers the possibility of configuring CONTO Energy meters using a simple and intuitive procedure by the creation of a customized project based on personal needs and the actual system installed.
- Note: IDM Configuration Software is free. To be downloaded from the IME web site. Once downloaded it will be useful for all remote configurations of CONTO Energy Meters
- Alat anu cocog
- Vérsi parangkat lunak 1.00.00
- Range CONTO
- Modbus
- Conto D2 63A 1ph Modbus (CE2DF3DTCL1)
- Conto D2 63A 1ph Modbus MID (CE2DF3DTMID)
- Conto D4 63A 3ph Modbus (CE4DF3DTCL1)
- Conto D4 63A 3ph Modbus MID(CE4DF3DTMID)
- Conto D4 5A 3ph Modbus(CE4TBDTCL1)
- Conto D4 5A 3ph Modbus MID(CE4TBDTMID)
- Mbus
- Conto D2 63A 1ph Mbus MID(CE2DF3MTMID)
- Conto D4 63A 3ph Mbus(CE4DF3MTCL1)
- Conto D4 5A 3ph Mbus(CE4TBMTCL1)
- Conto D4 5A 3ph Mbus MID(CE4TBMTMID)
- Vérsi parangkat lunak 1.00.00
- Basa sadia
- Basa:
- Inggris
- Français
- Italiano
- Basa:
Palaksanaan
- Bahan diperlukeun
- Installation Kit (executable file “.exe”)
- A computer with a compatible operating system (10, 7, etc.)
Pamasangan
- Ngajalankeun file
The installation procedure starts
- Choose the proper language
- Pencét "OK"
Click “Next” 3
- The License agreement page appears

- The License agreement page appears
- Click to declare to have read and accepted the contract
- Klik "Next"

- Click “Browse” to choose the installation folder
- Klik "Next"

- Click “Next.
- Pamasangan réngsé
- Pencét "Rengse"
- On the desktop of your computer are created two shortcuts: – Energy management software:
IME – Energy manager software
IME – NEMO SX Configurator
IME – IDM Configurator
Modification of the software’s language
- Procedure for changing language (if necessary)

In the software’s home page
- Click “Software configuration”

- Choose the required language
- Click “Save” to confirm.
Pilarian Alat
In the software’s home page
- Click “Search Device”
- The scan page is divided to 2 sections:
- A. Setélan saluran
- B. Setélan alat

- A. Setélan saluran
- The scan page is divided to 2 sections:
- Choose the correct Communication Protocols. 3 Software supports :
- Modbus RTU
- Modbus TCP
- M- bus
- Choose the correct COM port.
- Modbus RTU
- B. Setélan alat

- Verify and choose the Correct Baud rate and Parity, otherwise
- Choose the All Combinations.
- Search in a specific range of addresses
- Choose All addresses.
- Modbus TCP
- First of all, it is needed a TCP gateway interface.
- Pikeun example:
- SXIIP: gateway Ethernet/RS485 (1:N)
- In this case, you need to connect your PC to the same network of your Modbus TCP gateway. (Ethernet)

- Modbus TCP
- Enter the IP Address of your gateway.
- Search in a specific range of addresses or
- Choose All addresses
- M-beus
- First of all, you need a M-Bus Converter
- Choose the M-Bus Protocol.
- Choose the correct COM port.

- Verify and choose the Correct Baud rate and Parity, otherwise
- Click on Search button
- Note: You can search the Primary Addresses o the Secondary Addresses.
- Click Secondary Addressing for check.
- Nyeken

- Nyeken
- By clicking on the Search button, a page with the latest Firmware updates will be shoewn:
MID devices are not updatable
Apdet sayogi
- Click Update FW
- Click “Continue” to go to the edit page of the configuration read.
Ngamutahirkeun firmware alat
As soon as the search devices page appears, you can see if updated firmware is available for each module.
- You can check the small window on top to update all the available firmware updates
- Otherwise you can uncheck it and choose just the modules you would like to update
- Finally, click on the update FW button (it might take some time to update, please wait until the software finishes the process)
Konfigurasi Alat
Configuration of devices on your system In the Home page
- Click “Edit Configuration online”
- The Configuration Page will be appeared.
- Page Konfigurasi
- The page is divided into two sections:
- List of the devices
- Configuration Settings for the selected device on the section A

- The page is divided into two sections:
TO VIEW/CONFIGURE THE DEVICES CHARACTERISTICS In Settings
- Pilih Alat
- Ganti ngaran Alat
- Click “Connection” and choose the correct connection
- Click “External input” and choose the correct input
- Click for assign the other control parameter.
- Dina Advanced
- Click “Advanced” and a set additional parameters are shown
- Click for assign the other control parameters
- Click “Save” to confirm
Catetan:
Device connected to the Wi-Fi- Device not connected to the Wi-Fi
To be able to access the saved settings directly, click on “Export Configuration”. For more details, see page 26
- Configurable parameters of each module
- Examples of Configuration


- Examples of Configuration
- View kaca
- In the software’s Home page

- In the software’s Home page
- Click “Visualize project”
- Devices display page appears

- Devices display page appears
- The page is divided into two e sections:
-
- section shows the Devices (Network icon shows if your device is connected or no, (in all 3 protocols: Modbus RTU, Modbus TCP, M-bus)
- section is the area where is possible to select several pages (according to the functions present in a Device):
- Measure: display of the quantities measured by a device:
- Electricity measuring devices: Energy, Power, Voltages / Currents /Frequency, THD, and Harmonics
- THD and Harmonics are just available for the Easy Connects.
-
Catetan:
Indicates the active tariff
Off-line operation
Import a configuration In the Software’s home page
- Click “Import Configuration”
- System configuration appears

- System configuration appears
- Pilih nu file to import (e.g. Configuration.XML), then
- click “Open”
-
- Configuration is ready to be edit
-
- Export a configuration
In the System configuration page
- Click “Export configuration.”
- A pop-up window appears

- Select where to save file, tuluy
- Klik "Simpen"
- Configuration is saved on your computer
- A pop-up window appears
Patarosan anu sering ditaroskeun
Q: What are the supported communication protocols for device settings?
A: The software supports Modbus RTU, Modbus TCP, and M-bus protocols for device settings.