1. Produk Langkungview

The Your Cee Weighing Acquisition Module is a high-performance and multifunctional electronic weighing device that utilizes advanced weighing sensing technology. It is designed to measure the weight of an item in real-time and display it on a five-digit digital tube. This module incorporates an upper and lower limit alarm function, enabling precise weighing control and monitoring for various applications.

The product features a TTL communication interface and supports the standard MODBUS RTU communication protocol. This allows for convenient and rapid communication with external devices such as PLCs and computers, facilitating the transmission and remote control of weighing data. Additionally, it supports Type-C/5V power supply and includes button debugging functions, enhancing its convenience and operational stability.

Fitur konci:

  • High-precision weighing sensor for accurate weight detection and numerical display.
  • Five-digit digital tube display for intuitive and clear readings, suitable for efficient weighing processes.
  • Upper and lower limit alarm function for early warning and strict control, improving quality assurance.
  • Supports TTL communication interface and MODBUS RTU protocol for convenient data transmission and remote control.
  • Type-C/5V power supply and integrated button debugging functions for ease of use and strong stability.
  • Lightweight and portable design, making it easy to install and move, saving space and costs.

This weighing collection module is a practical, high-performance, and multifunctional electronic weighing device suitable for a wide range of weighing measurement and control applications in production lines and logistics warehousing, enabling remote data transmission and precise control.

2. Spésifikasi

AtributNilai
Ngaran BrandYour Cee
TipeSénsor Geter
TéoriInductance Sensor
KaluaranSénsor analog
PakéSénsor tekanan
BahanCampuran
AsalnaDaratan Cina
is_customizedSumuhun
Kimia anu prihatin tinggiEuweuh

ukuran:

  • Panjangna: 54 mm
  • rubak: 34 mm
Module dimensions: 54mm length, 34mm width.
Figure 2.1: Module dimensions (54mm x 34mm).

3. Eusi Paket

Paket biasana kalebet:

  • 1x or 2x Load Cell AD Weight Pressure Sensor Module (HX710 / YR-3180)

Note: Load cells, connecting cables, and external display units are usually sold separately.

4. Setup jeung Wiring

Proper connection of the module is crucial for its functionality. Refer to the wiring diagram below for detailed connections.

4.1 suplai kakuatan

  • The module is powered via a Type-C port, requiring a 5V DC input.
  • Connect a standard Type-C 5V power source to the module's Type-C port.
  • The module provides a stable 3.3V output for the connected sensor.

4.2 Beban Cell Connection

Connect your load cell to the module using the following pins:

  • E+ (Excitation+): Connect to the positive excitation of the load cell.
  • E- (Excitation-): Connect to the negative excitation of the load cell.
  • S+ (Signal+): Connect to the positive signal output of the load cell.
  • S- (Signal-): Connect to the negative signal output of the load cell.

4.3 Alarm Output Connection

The module provides two alarm output pins:

  • AL1: Alarm output 1.
  • AL2: Alarm output 2.

These can be connected to external relay modules or other control circuits to trigger actions based on weight thresholds.

4.4 Interface Komunikasi

The module supports TTL communication with Modbus RTU protocol. Connect to your communication device (e.g., PLC, microcontroller, computer via a TTL-to-USB converter) using the following pins:

  • RX (nampi): Data input to the module.
  • TX (Pangiriman): Data output from the module.
  • GND: Ground connection for communication.
  • 5v: Power supply for communication (optional, depending on external device).
Wiring diagram for the weighing module showing connections for load cell, power, alarm outputs, and TTL communication.
Gambar 4.1: Diagram Kabel
Video 4.1: Demonstration of module setup and alarm functionality.

5. Parentah Operasi

The module features a 5-digit LED display and four control buttons for local operation and debugging.

Ti luhur ka handap view of the weighing module showing the 5-digit LED display and four control buttons with Chinese labels.
Figure 5.1: Module with LED Display and Buttons

5.1 Fungsi Tombol:

  • Settings (设置): Used to enter or exit configuration menus and confirm selections.
  • Shift / Tare (移位/除皮): Used to shift digits during numerical input or to perform a tare operation (zeroing the current weight).
  • Add Key / Clear (加键/清零): Used to increment values during numerical input or to clear certain settings.
  • Subtract Key / Zero Point (减键/零点): Used to decrement values during numerical input or to set the zero point.

5.2 Weighing Display

Once powered and calibrated, the 5-digit LED display will show the real-time weight measured by the connected load cell.

5.3 Kalibrasi

Calibration is essential for accurate measurements. The module supports calibration via both the onboard buttons and through the communication interface. Refer to the detailed protocol document for communication-based calibration procedures. For button-based calibration:

  1. Enter calibration mode using the 'Settings' button.
  2. Follow the on-screen prompts to set the zero point using the 'Subtract Key / Zero Point' button.
  3. Apply a known reference weight and adjust the span using the 'Add Key / Clear' and 'Subtract Key / Zero Point' buttons.
  4. Save settings using the 'Settings' button.

5.4 Fungsi Alarm

The module can be configured with upper and lower weight limits. If the measured weight exceeds the upper limit or falls below the lower limit, the corresponding alarm output (AL1 or AL2) will activate. These limits can be set via the buttons or through the communication interface.

6. Communication (TTL & Modbus RTU)

The module provides a TTL serial communication interface and supports the standard Modbus RTU protocol, allowing for integration into larger control systems.

6.1 TTL Interface

The TTL interface operates at 5V logic levels. Ensure your connecting device is compatible or use appropriate level shifters.

6.2 Modbus RTU Protokol

The module acts as a Modbus RTU slave device. You can read weighing data, set alarm thresholds, and perform calibration commands by sending Modbus RTU requests from a master device (e.g., PLC, HMI, PC software).

For detailed Modbus register addresses, function codes, and communication parameters (baud rate, parity, stop bits), please refer to the specific Modbus RTU protocol documentation provided by the manufacturer. This documentation is essential for developing custom software or configuring Modbus master devices.

7. Tips pamaké

  • Jelas tampilan: The 5-digit LED display provides clear and immediate feedback on the measured weight.
  • Kapasitas Timbangan: The maximum weighing capacity of your setup depends entirely on the specifications of the load cell connected to the module, not the module itself. Always ensure your load cell is rated for the expected weight range.
  • Konfigurasi Alarm: Utilize the upper and lower limit alarm functions to automate processes or alert operators when weight thresholds are met. These can be adjusted via buttons or communication.
  • Communication for Advanced Control: For complex systems or remote monitoring, leverage the Modbus RTU communication to integrate the module with PLCs or other industrial control systems.

8. Cara ngungkulan

8.1 Taya Témbongkeun / Power

  • Ensure the Type-C power cable is securely connected and receiving 5V DC.
  • Check the power source for proper operation.

8.2 Incorrect Weight Readings

  • Verify all load cell connections (E+, E-, S+, S-) are correct and secure.
  • Perform a calibration procedure as described in Section 5.3.
  • Ensure the load cell is properly installed and not subjected to external forces or vibrations.
  • Check for any physical damage to the load cell or module.

8.3 Masalah Komunikasi

  • Check RX, TX, and GND connections for the TTL interface.
  • Verify communication parameters (baud rate, parity, stop bits) match between the module and the master device.
  • Ensure the Modbus RTU protocol is correctly implemented on the master side.
  • Confirm that the module's Modbus slave address is correctly set and matches the master's request.

8.4 Alarm Not Triggering

  • Check the configured upper and lower alarm limits to ensure they are set correctly.
  • Verify connections to AL1 and AL2 outputs.
  • Test the external alarm circuit (e.g., relay module) independently.

9. Pangropéa

  • beberesih: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using harsh chemicals or abrasive materials.
  • Kaayaan Lingkungan: Operate the module within its specified environmental conditions (temperature, humidity) to ensure optimal performance and longevity.
  • Perlindungan Uap: Protect the module from moisture and liquids. If exposed to moisture, disconnect power immediately and allow it to dry completely before re-applying power.
  • Penanganan fisik: Handle the module with care to avoid physical damage to the PCB, components, or connectors.

10. Garansi jeung Rojongan

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Ensure you have your product model and purchase details available when seeking support.