Solinved - logoPWM Series Solar Charge Controller
User Manual

SAFETY INSTRUCTIONS

  1. Make sure your battery has enough voltage for the controller to recognize the battery type before first installation.
  2. The battery cable should be as short as possible to minimize loss.
  3. The regulator is only suitable for lead acid batteries: OPEN, AGM, GEL it is not suited for nickel metal hydride, lithium ions or other batteries.
  4. The charge regulator is only suitable for regulating solar modules. Never connect another charging source to the charge regulator.

PRODUCT FEATURES

  1. Build-in industrial micro controller.
  2. Big LCD display,all adjustable parameter.
  3. Fully 3-stage charge management. 4.Build-in short-circuit protection, open-circuit protection, reverse protection. Over-load protection.
  4. Dual USB output, the maximum current of 2.5A, to support Apple’s mobile phone charging.
  5. .Duai misfit Reverse current protection,low heat production.

LCD DISPLAY/KEY
Solinved PWM Series Solar Charge Controller - dispalyMENU:
Switch between different display or to enter/exjt setting by long press. Up :press to increaae value. DOWN:Press to decrease value.
SYSTEM CONNECTION

  1. connect the battery to the charge regulator-plus and minus.
  2. Connect the photovoltaic module to the regulator-plus and minus.
  3. Connect the consumer to the charge regulator-plus and minus.

The reverse order applies when reinstalling! An improper sequence order can damage the controller!
Solinved PWM Series Solar Charge Controller - dispaly 1 Note :12V battery with 18V solar pane1,24V battery with 36V solar panel
LCD DISPLAY/SEETING Solinved PWM Series Solar Charge Controller - seetingAttn: 1 .Press the [DOWN] button to ON/OF load manfully at main display. 2.The work mode is working as below.
[24H] load output 24 hours [1-23H] load on after sunset and dosed atfer setting hours [OH] Dusk to dawn

TROUBLE SHOOTING

Situation Probable cause Solution
Charge icon not on when sunny Solar panel opened or reversed Reconnect
Load icon off Mode setting wrong Set again
Battery low Recharge
Load icon slow flashing Over load Reduce load watt
Short circuit prelection Remove short circuit, 1 minutes or so automatic recovery
Power off Battery too low! reverse Check battery/connection

TECHNICAL PARAMETER

Batt voltage 12V/24V auto
MODEL W88-A W88-8 W88-C W88-D W88-E W88-F
Charge current 10A 20A 30A 40A 50A 60A
Discharge current WA 10A t0A 30A 30A 30A
Max solar input 12V battery, thghi highest 23c24vbatecwenl highest 46V
Equalization B1 sealed B2 gel B3 flood
14.4V 14. 2V 14 6V
Float charge 14.4V defaul,adjustable
Discharge stop 10.7V ldefaul,adjustable
Discharge
reconnect
12.6V(defaul,adjustable)
Charge reconnect 13.2V
Voltage of open light Solar panel 8V(Light lights delay)
Voltage of close light Solar panel 8V(Light off delay)
USB output 2 way USB output, 5V/2.5A(MAX)
Self-consume <10mA
Operating temperature -35 — +60C
Size/Weight 133.5 • 70 * 35mm / 165g
  • All red color voltage x2 while using 24V system
  • This instruction is a general manual, such as a slight difference in the physical.
  • Product specifications are subject to change without prior notice

Solinved - logo

Documents / Resources

Solinved PWM Series Solar Charge Controller [pdf] User Manual
PWM Series Solar Charge Controller, PWM Series, Solar Charge Controller, Charge Controller

References

Leave a comment