User's Manual

SAFETY INSTRUCTIONS

  1. Make sure your battery has enough voltage for the controller to recognize the battery type before first installation.
  2. The battery cable should be as short as possible to minimize loss.
  3. The regulator is only suitable for lead acid batteries: OPEN, AGM, GEL. It is not suited for nickel metal hydride, lithium ions or other batteries.
  4. The charge regulator is only suitable for regulating solar modules. Never connect another charging source to the charge regulator.

PRODUCT FEATURES

  1. Build-in industrial micro controller.
  2. Big LCD display, all adjustable parameters.
  3. Fully 3-stage charge management.
  4. Build-in short-circuit protection, open-circuit protection, reverse protection, over-load protection.
  5. Dual USB output, the maximum current of 2.5A, to support Apple's mobile phone charging.
  6. Dual mosfet Reverse current protection, low heat production.

LCD DISPLAY/KEY

Note: 12V battery with 18V solar panel, 24V battery with 36V solar panel

Diagram showing the solar charge controller unit with connections for solar panel, battery, and load. It also illustrates the LCD display with various readings and buttons.

LCD DISPLAY/SETTING

Main display

13.2V

Full of voltage

14.4V

Battery type

B1 sealed

Work mode

24H

Browsing Interface: Press MENU to browse different interfaces.

Set parameter: In interface 2-5, long press MENU to enter setting, and using UP/DOWN to set the parameter, long press MENU again to exit. Long press DOWN to restore parameter.

Attn:

  1. Press the [DOWN] button to ON/OFF load manually at main display.
  2. The work mode is working as below:
    • [24H] load output 24 hours
    • [1-23H] load on after sunset and closed after setting hours
    • [OH] Dusk to dawn

SYSTEM CONNECTION

  1. Connect the battery to the charge regulator - plus and minus.
  2. Connect the photovoltaic module to the regulator - plus and minus.
  3. Connect the consumer to the charge regulator - plus and minus.
Diagram illustrating the correct wiring sequence for connecting the battery, solar panel, and load to the charge controller.

TROUBLE SHOOTING

Situation Probable cause Solution
Charge icon not on when sunny Solar panel opened or reversed Reconnect
Load icon off Mode setting wrong Set again
Load icon slow flashing Battery low Recharge
Power off Over load Reduce load watt
Short circuit protection Remove short circuit, 1 minutes or so automatic recovery
Battery too low/reverse Check battery/connection

TECHNICAL PARAMETER

W88-A W88-B W88-C W88-D W88-E W88-F
MODEL 12V/24V auto 12V/24V auto 12V/24V auto 12V/24V auto 12V/24V auto 12V/24V auto
Charge current 10A 20A 30A 40A 50A 60A
Discharge current 10A 10A 10A 30A 30A 30A
Max solar input voltage 12V battery, the highest 23V; 24V battery when the highest 46V
Blue solar input 200W/400W (12V/24V auto)
Equalization 14.4V 14.2V 14.6V B1 sealed B2 gel B3 flood
Float charge 13.8V (default, adjustable)
Load output 12.6V (default, adjustable)
Discharge stop voltage 10.7V (default, adjustable)
Discharge reconnect voltage 13.2V
Solar panel voltage 8V (Light lights delay)
Voltage of open light Solar panel 8V (Light off delay)
Voltage of close light Solar panel 8V (Light off delay)
USB output 2 way USB output, 5V/2.5A(MAX)
Self-consume <10mA
Operating temperature -35~+60°C
Size/Weight 133.5*70*35mm / 165g

*All red color voltage x2 while using 24V system

*This instruction is a general manual, such as a slight difference in the physical.

*Product specifications are subject to change without prior notice.

Models: PWM Series Solar Charge Controller, PWM Series, Solar Charge Controller, Charge Controller

PDF preview unavailable. Download the PDF instead.

pwm-serisi-manual Scan Assistant secPdfProducer