User's Manual
SAFETY INSTRUCTIONS
- Make sure your battery has enough voltage for the controller to recognize the battery type before first installation.
- The battery cable should be as short as possible to minimize loss.
- The regulator is only suitable for lead acid batteries: OPEN, AGM, GEL. It is not suited for nickel metal hydride, lithium ions or other batteries.
- The charge regulator is only suitable for regulating solar modules. Never connect another charging source to the charge regulator.
PRODUCT FEATURES
- Build-in industrial micro controller.
- Big LCD display, all adjustable parameters.
- Fully 3-stage charge management.
- Build-in short-circuit protection, open-circuit protection, reverse protection, over-load protection.
- Dual USB output, the maximum current of 2.5A, to support Apple's mobile phone charging.
- Dual mosfet Reverse current protection, low heat production.
LCD DISPLAY/KEY
Note: 12V battery with 18V solar panel, 24V battery with 36V solar panel
Diagram showing the solar charge controller unit with connections for solar panel, battery, and load. It also illustrates the LCD display with various readings and buttons.
LCD DISPLAY/SETTING
Main display
13.2V |
Full of voltage
14.4V |
Battery type
B1 sealed |
Work mode
24H |
Browsing Interface: Press MENU to browse different interfaces.
Set parameter: In interface 2-5, long press MENU to enter setting, and using UP/DOWN to set the parameter, long press MENU again to exit. Long press DOWN to restore parameter.
Attn:
- Press the [DOWN] button to ON/OFF load manually at main display.
- The work mode is working as below:
- [24H] load output 24 hours
- [1-23H] load on after sunset and closed after setting hours
- [OH] Dusk to dawn
SYSTEM CONNECTION
- Connect the battery to the charge regulator - plus and minus.
- Connect the photovoltaic module to the regulator - plus and minus.
- Connect the consumer to the charge regulator - plus and minus.
Diagram illustrating the correct wiring sequence for connecting the battery, solar panel, and load to the charge controller.
TROUBLE SHOOTING
Situation | Probable cause | Solution |
---|---|---|
Charge icon not on when sunny | Solar panel opened or reversed | Reconnect |
Load icon off | Mode setting wrong | Set again |
Load icon slow flashing | Battery low | Recharge |
Power off | Over load | Reduce load watt |
Short circuit protection | Remove short circuit, 1 minutes or so automatic recovery | |
Battery too low/reverse | Check battery/connection |
TECHNICAL PARAMETER
W88-A | W88-B | W88-C | W88-D | W88-E | W88-F | |
---|---|---|---|---|---|---|
MODEL | 12V/24V auto | 12V/24V auto | 12V/24V auto | 12V/24V auto | 12V/24V auto | 12V/24V auto |
Charge current | 10A | 20A | 30A | 40A | 50A | 60A |
Discharge current | 10A | 10A | 10A | 30A | 30A | 30A |
Max solar input voltage | 12V battery, the highest 23V; 24V battery when the highest 46V | |||||
Blue solar input | 200W/400W (12V/24V auto) | |||||
Equalization | 14.4V | 14.2V | 14.6V | B1 sealed | B2 gel | B3 flood |
Float charge | 13.8V (default, adjustable) | |||||
Load output | 12.6V (default, adjustable) | |||||
Discharge stop voltage | 10.7V (default, adjustable) | |||||
Discharge reconnect voltage | 13.2V | |||||
Solar panel voltage | 8V (Light lights delay) | |||||
Voltage of open light | Solar panel 8V (Light off delay) | |||||
Voltage of close light | Solar panel 8V (Light off delay) | |||||
USB output | 2 way USB output, 5V/2.5A(MAX) | |||||
Self-consume | <10mA | |||||
Operating temperature | -35~+60°C | |||||
Size/Weight | 133.5*70*35mm / 165g |
*All red color voltage x2 while using 24V system
*This instruction is a general manual, such as a slight difference in the physical.