VETEK-logo

VETEK OCS-Y2 Compact Crane Scale

VETEK-OCS-Y2-Compact-Crane-Scale-product

Product Usage Instructions

Introduction

Notice: Before using the dynamometer, carefully read the manual and keep it for future reference.

Safety Guide:

  • Do NOT overload the dynamometer to avoid damage to loadcell and warranty void.
  • Avoid leaving weight loaded on the dynamometer for extended periods to maintain accuracy.
  • Replace the battery with full ones when the dynamometer runs out of power.
  • Avoid using the dynamometer under thunder or rain conditions.
  • Do NOT attempt to repair the dynamometer yourself; contact your local representative for assistance.

 Display & Keys
The dynamometer features various keys with different functions:

  • Scale Keys:
    • Key Name: Function
    • Short pressing: Cancel & On/Off; Long pressing: Power-on/off
    • Short pressing: Tare in/out; Long pressing: Zero; Move digit
    • Short pressing: Lock/unlock; Long pressing: Unit Switch; Input/cancel decimal point

Indicators:

  • LED Name – Note
  • Stable: shown when weight is stable
  • Zero: shown when weight is at zero
  • Hold: shown when scale is tared
  • Peak Hold: shown when weight in peak mode
  • lb/kg/UN: unit indicators

Operations

Power On/Off: Simultaneously press the designated key for power on/off function.

Frequently Asked Questions (FAQ)

Q: How do I change the battery of the dynamometer?
A: To replace the battery, follow these steps:

  1. Open the battery compartment.
  2. Remove the old batteries.
  3. Insert new batteries in the correct orientation.
  4. Close the battery compartment securely.

Q: Can the dynamometer be used in extreme temperature conditions?
A: The dynamometer is designed to operate within a specific temperature range. Avoid using it in extreme temperature conditions outside this range to ensure accurate measurements and device longevity.

 Introduction

Notice
Before you use this dynamometer, please read this manual through carefully, and keep it properly for future use.

Safety Guide
For good performance and precise measurement, be careful with daily operation and maintenance. Note the following instructions:

  • Do NOT overload dynamometer. This will damage loadcell and void warranty.
  • Do NOT leave weight loaded on dynamometer for long. This will decrease dynamometer’s accuracy and shorten loadcell’s life.
  • When dynamometer runs out of power, replace the battery with full ones.
  • Do NOT use dynamometer under thunder or rain.
  • Do NOT attempt to repair dynamometer yourself. Contact your local representative.

Specifications

Features
This dynamometer is a combination of the sound and proven mechanical design, with today’s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.

Superb Quality Strictly in accordance with Chinese GB/T11883-2002 national standards, andEuropean CE directives.
Great Safety Quality aluminum or steel casefor better safety.
NewestDesign 2-line digits FSTN LCD display,with optional shackle and hook.
Leading Technology SMT technology, quality integrated circuit and dedicatedweighing loadcell, ensures long

time stability.
SmartPower-saving 3*AA battery with low powerconsumption design.
Portable Compact structure, easy to carry.

Specifications

Accuracy ≤±0.1%F.S.
Tare Range 100% F.S.
Overload Alarm >F.S.+9e
Max. Safety Load 120% F.S.
Ultimate Load 400% F.S.
Battery 3*AA 1.5V battery
Battery Life >30hours
Temp. (Op.) – 10℃ ~ + 40℃
Display 43mm(16.92inch) screen 22mm(8.663inch) character

Display & Keys

Scale Keys 

VETEK-OCS-Y2-Compact-Crane-Scale- (2)

Indicators  VETEK-OCS-Y2-Compact-Crane-Scale- (3)

Message VETEK-OCS-Y2-Compact-Crane-Scale- (5) VETEK-OCS-Y2-Compact-Crane-Scale- (6)

 

Operations

Power On/Off

  • Simultaneously pressVETEK-OCS-Y2-Compact-Crane-Scale- (1) for 1s to power-on  scale. Scale perform initialization and power-on test, VETEK-OCS-Y2-Compact-Crane-Scale- (7)shows twice, then capacityVETEK-OCS-Y2-Compact-Crane-Scale- (10) shows, battery life percentage showsVETEK-OCS-Y2-Compact-Crane-Scale- (9) weight detection shows and then auto zero.
  • For information about Auto-Zero, refer to Scale Configuration in Technical Manual.
  • Simultaneously press  VETEK-OCS-Y2-Compact-Crane-Scale- (1) for 1s to power-off scale. Battery life percentageVETEK-OCS-Y2-Compact-Crane-Scale- (11) shows, off messageVETEK-OCS-Y2-Compact-Crane-Scale- (12) shows, and then cut off power.
  • When 3 batteries voltage is lower than 3.2V, scale will auto power-off itself and display .VETEK-OCS-Y2-Compact-Crane-Scale- (14) Please replace the dead batteries with new ones.

Zero

  • Simultaneously press VETEK-OCS-Y2-Compact-Crane-Scale- (18)for 1s to zeroVETEK-OCS-Y2-Compact-Crane-Scale- (17). shows.
  • If load is in motion, or tared, or out of Manual-Zero RangeVETEK-OCS-Y2-Compact-Crane-Scale- (20), shows.
  • For information about Manual-Zero Range, refer to Scale Configuration in Technical Manual.

Tare In/Out

  • In gross mode, pressVETEK-OCS-Y2-Compact-Crane-Scale- (18) to tare in. shows.
  • If load is in motion, or negative, or out of Tare

RangeVETEK-OCS-Y2-Compact-Crane-Scale- (20), shows.

  • Tare will reduce the apparent overload range of scale. For example, if a 500*0.2kg scale has a 100kg container as its tare, the scale will overload at a new weight of 401.8kg (500 – 100 + additional 9 divisions).
  • In net weight mode, press VETEK-OCS-Y2-Compact-Crane-Scale- (18)to tare outVETEK-OCS-Y2-Compact-Crane-Scale- (19). disappears.

Lock/Unlock

  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (22)to lock screenH. shows.
  • PressVETEK-OCS-Y2-Compact-Crane-Scale- (22) to unlock screen. H disappears.

Unit Switch

  • Simultaneously press VETEK-OCS-Y2-Compact-Crane-Scale- (22)for 1s to switch unit in between kg, lb, and User Unit.
  • When unit is kg, VETEK-OCS-Y2-Compact-Crane-Scale- (23)shows. When unit is lb,VETEK-OCS-Y2-Compact-Crane-Scale- (24) shows. When unit is User unit, showsVETEK-OCS-Y2-Compact-Crane-Scale- (25).
  • For more information about User Unit, refer to Scale Configuration in Technical Manual.

Peak Hold

  • In weight mode, press VETEK-OCS-Y2-Compact-Crane-Scale- (26)to peak hold function,“P” shows.
  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (26)again to exit peak mode,VETEK-OCS-Y2-Compact-Crane-Scale- (27) disappears.
  • In peak mode, weigh will be locked,

When the weigh is higher than the previous one, automatically display higher one and locked again.

Remark: Press twiceVETEK-OCS-Y2-Compact-Crane-Scale- (26) also could unlock PEAK Function.

User Setup

  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (28) at the same time for 1s to enter User Setup menu. shows.

Auto-Off Timing

  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (22)to enter Auto-Off TimingVETEK-OCS-Y2-Compact-Crane-Scale- (12). shows.
  • PressVETEK-OCS-Y2-Compact-Crane-Scale- (29) to change timing value.
  • Auto-Off Timing can be set to: VETEK-OCS-Y2-Compact-Crane-Scale- (30)(disabled), (5min),5 (10min),10 (15min), 15(30min), 30(60min). It is disabled by default.
  • Auto-Off function maximizes scale’s battery life against people’s carelessness not to power off scale when it’s not working.
  • Auto-Off starts countdown timer when there’s no action or load is stable. Any key pressing or motion in load restarts countdown timer.

Backlight Brightness

  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (35)to enter Backlight Brightness. VETEK-OCS-Y2-Compact-Crane-Scale- (31)shows.
  • PressVETEK-OCS-Y2-Compact-Crane-Scale- (29) to change brightness value.
  • Backlight Brightness can be set to:VETEK-OCS-Y2-Compact-Crane-Scale- (12) (disabled),1 (dim)2, (normal)3(bright).
  • Dim backlight brightness saves battery power dramatically.

Idle Mode Timing

  • PressVETEK-OCS-Y2-Compact-Crane-Scale- (35) to enter Idle Mode Timing.VETEK-OCS-Y2-Compact-Crane-Scale- (31) shows.
  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (29)to change timing value.
  • Idle Mode Timing can be set to:VETEK-OCS-Y2-Compact-Crane-Scale- (12) (disabled),5 (5sec),10 (10sec),15 (15sec),30 (30sec),60 (60sec). It is 30sec by default.

To maximize battery life, scale automatically enters Idle Mode, when there’s no action or the load is stable.

In Idle Mode, scale works in low-power consumption status. Any key pressing or motion in load wakes up scale from Idle Mode.

  • Press VETEK-OCS-Y2-Compact-Crane-Scale- (35)to exit User Setup.

 Trouble-shoot

Simple problems can be resolved as below listed solution. If problems still exist, please contact your local representative.

Symptom Possible Cause Suggested Solution
not power-on after VETEK-OCS-Y2-Compact-Crane-Scale- (1)is pressed discharged /defective battery check battery andreplace
defective On/Offkey press harder and keeppressing for 2s
defective power open front panel, check
defective contact representative
mainboard
backlightflashes dischargedbattery  replace battery
no action taken after keypressed scale is disturbed re-plug power cable
  defective key   contact representative
   weight reading not stable load in motion keep load stable
weakAnti-Motion change Anti-Motionlevel
damped loadcellor mainboard dry loadcell ormainboard
defectivemainboard  contact representative
 weight reading not zero when no load dischargedbattery  replace battery
load-cell stressedtoo long  hang scale in storage
loadcell drifts contact representative
large errorin weight scale not zeroedbefore applying Manual Zero scalebefore loading
reading load
wrong unit switch to correct unit
scale requirescalibration  calibrate scale
defective loadcellor mainboard  contact representative

Documents / Resources

VETEK OCS-Y2 Compact Crane Scale [pdf] User Guide
OCS-Y2, OCS-Y2 Compact Crane Scale, Compact Crane Scale, Crane Scale, Scale

References

Leave a comment

Your email address will not be published. Required fields are marked *