VETEK OCS-Y2 Compact Crane Scale
Product Usage Instructions
Introduction
Notice: Before using the dynamometer, carefully read the manual and keep it for future reference.
Safety Guide:
- Do NOT overload the dynamometer to avoid damage to loadcell and warranty void.
- Avoid leaving weight loaded on the dynamometer for extended periods to maintain accuracy.
- Replace the battery with full ones when the dynamometer runs out of power.
- Avoid using the dynamometer under thunder or rain conditions.
- Do NOT attempt to repair the dynamometer yourself; contact your local representative for assistance.
Display & Keys
The dynamometer features various keys with different functions:
- Scale Keys:
- Key Name: Function
- Short pressing: Cancel & On/Off; Long pressing: Power-on/off
- Short pressing: Tare in/out; Long pressing: Zero; Move digit
- Short pressing: Lock/unlock; Long pressing: Unit Switch; Input/cancel decimal point
Indicators:
- LED Name – Note
- Stable: shown when weight is stable
- Zero: shown when weight is at zero
- Hold: shown when scale is tared
- Peak Hold: shown when weight in peak mode
- lb/kg/UN: unit indicators
Operations
Power On/Off: Simultaneously press the designated key for power on/off function.
Frequently Asked Questions (FAQ)
Q: How do I change the battery of the dynamometer?
A: To replace the battery, follow these steps:
- Open the battery compartment.
- Remove the old batteries.
- Insert new batteries in the correct orientation.
- Close the battery compartment securely.
Q: Can the dynamometer be used in extreme temperature conditions?
A: The dynamometer is designed to operate within a specific temperature range. Avoid using it in extreme temperature conditions outside this range to ensure accurate measurements and device longevity.
Introduction
Notice
Before you use this dynamometer, please read this manual through carefully, and keep it properly for future use.
Safety Guide
For good performance and precise measurement, be careful with daily operation and maintenance. Note the following instructions:
- Do NOT overload dynamometer. This will damage loadcell and void warranty.
- Do NOT leave weight loaded on dynamometer for long. This will decrease dynamometer’s accuracy and shorten loadcell’s life.
- When dynamometer runs out of power, replace the battery with full ones.
- Do NOT use dynamometer under thunder or rain.
- Do NOT attempt to repair dynamometer yourself. Contact your local representative.
Specifications
Features
This dynamometer is a combination of the sound and proven mechanical design, with today’s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.
Superb Quality | Strictly in accordance with Chinese GB/T11883-2002 national standards, andEuropean CE directives. |
Great Safety | Quality aluminum or steel casefor better safety. |
NewestDesign | 2-line digits FSTN LCD display,with optional shackle and hook. |
Leading Technology | SMT technology, quality integrated circuit and dedicatedweighing loadcell, ensures long |
time stability. | |
SmartPower-saving | 3*AA battery with low powerconsumption design. |
Portable | Compact structure, easy to carry. |
Specifications
Accuracy | ≤±0.1%F.S. |
Tare Range | 100% F.S. |
Overload Alarm | >F.S.+9e |
Max. Safety Load | 120% F.S. |
Ultimate Load | 400% F.S. |
Battery | 3*AA 1.5V battery |
Battery Life | >30hours |
Temp. (Op.) | – 10℃ ~ + 40℃ |
Display | 43mm(16.92inch) screen 22mm(8.663inch) character |
Display & Keys
Scale Keys
Indicators
Message
Operations
Power On/Off
- Simultaneously press
for 1s to power-on scale. Scale perform initialization and power-on test,
shows twice, then capacity
shows, battery life percentage shows
weight detection shows and then auto zero.
- For information about Auto-Zero, refer to Scale Configuration in Technical Manual.
- Simultaneously press
for 1s to power-off scale. Battery life percentage
shows, off message
shows, and then cut off power.
- When 3 batteries voltage is lower than 3.2V, scale will auto power-off itself and display .
Please replace the dead batteries with new ones.
Zero
- Simultaneously press
for 1s to zero
. shows.
- If load is in motion, or tared, or out of Manual-Zero Range
, shows.
- For information about Manual-Zero Range, refer to Scale Configuration in Technical Manual.
Tare In/Out
- In gross mode, press
to tare in. shows.
- If load is in motion, or negative, or out of Tare
Range, shows.
- Tare will reduce the apparent overload range of scale. For example, if a 500*0.2kg scale has a 100kg container as its tare, the scale will overload at a new weight of 401.8kg (500 – 100 + additional 9 divisions).
- In net weight mode, press
to tare out
. disappears.
Lock/Unlock
- Press
to lock screenH. shows.
- Press
to unlock screen. H disappears.
Unit Switch
- Simultaneously press
for 1s to switch unit in between kg, lb, and User Unit.
- When unit is kg,
shows. When unit is lb,
shows. When unit is User unit, shows
.
- For more information about User Unit, refer to Scale Configuration in Technical Manual.
Peak Hold
- In weight mode, press
to peak hold function,“P” shows.
- Press
again to exit peak mode,
disappears.
- In peak mode, weigh will be locked,
When the weigh is higher than the previous one, automatically display higher one and locked again.
Remark: Press twice also could unlock PEAK Function.
User Setup
- Press
at the same time for 1s to enter User Setup menu. shows.
Auto-Off Timing
- Press
to enter Auto-Off Timing
. shows.
- Press
to change timing value.
- Auto-Off Timing can be set to:
(disabled), (5min),5 (10min),10 (15min), 15(30min), 30(60min). It is disabled by default.
- Auto-Off function maximizes scale’s battery life against people’s carelessness not to power off scale when it’s not working.
- Auto-Off starts countdown timer when there’s no action or load is stable. Any key pressing or motion in load restarts countdown timer.
Backlight Brightness
- Press
to enter Backlight Brightness.
shows.
- Press
to change brightness value.
- Backlight Brightness can be set to:
(disabled),1 (dim)2, (normal)3(bright).
- Dim backlight brightness saves battery power dramatically.
Idle Mode Timing
- Press
to enter Idle Mode Timing.
shows.
- Press
to change timing value.
- Idle Mode Timing can be set to:
(disabled),5 (5sec),10 (10sec),15 (15sec),30 (30sec),60 (60sec). It is 30sec by default.
To maximize battery life, scale automatically enters Idle Mode, when there’s no action or the load is stable.
In Idle Mode, scale works in low-power consumption status. Any key pressing or motion in load wakes up scale from Idle Mode.
- Press
to exit User Setup.
Trouble-shoot
Simple problems can be resolved as below listed solution. If problems still exist, please contact your local representative.
Symptom | Possible Cause | Suggested Solution |
not power-on after ![]() |
discharged /defective battery | check battery andreplace |
defective On/Offkey | press harder and keeppressing for 2s | |
defective power | open front panel, check | |
defective | contact representative |
mainboard | ||
backlightflashes | dischargedbattery | replace battery |
no action taken after keypressed | scale is disturbed | re-plug power cable |
defective key | contact representative | |
weight reading not stable | load in motion | keep load stable |
weakAnti-Motion | change Anti-Motionlevel | |
damped loadcellor mainboard | dry loadcell ormainboard | |
defectivemainboard | contact representative | |
weight reading not zero when no load | dischargedbattery | replace battery |
load-cell stressedtoo long | hang scale in storage | |
loadcell drifts | contact representative | |
large errorin weight | scale not zeroedbefore applying | Manual Zero scalebefore loading |
reading | load | |
wrong unit | switch to correct unit | |
scale requirescalibration | calibrate scale | |
defective loadcellor mainboard | contact representative |
Documents / Resources
![]() |