vetek OCS-S1 High Resolution Digital Crane Scale
Safety Guide
For good performance and precise measurement, be careful with daily operation and maintenance.
- Do NOT overload scale. This will damage loadcell and void warranty.
- Do NOT leave load hung on the scale for long. This will decrease scale’s accuracy and shorten loadcell’s life.
- Inspect shackle and hook before using. Check clips, pins and screws regularly.
- Check battery frequently. When scale runs out of power, replace the dead batteries with new ones.
- Rotate load rather than scale if needed.
- Do NOT use scale under thunder or rain.
- Hang scale on shelf in dry and well-ventilated room. Do NOT place scale on the ground directly.
- Do NOT attempt to repair scale yourself. Contact your local representative.
Features
This scale is a combination of sound and proven mechanical design, with today’s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.
- Superb Quality. Strictly in accordance with OIML R76, Chinese GB/T11883-2002 national standards, and European CE directives.
- Great Safety. Aluminum-casting case, high firm hook and shackle, dedicated weighing loadcell for safety installation.
- Strong Reliability. Cutting-edge technology, quality integrated circuit for high performance and long-time stability.
- Broad Applicability. Popular and applicable in storage, textile, metallurgy industry, and so forth.
- Complete Function. Resolution switch, unit conversion, auto power-off, battery inspection, etc.
Specifications
Accuracy | Chinese GB/T 11883-2002 CIII eqv. OIML R76 |
Tare Range | 100% F.S. |
Auto Zero | ±20% F.S. |
Manual Zero | ±4% F.S. |
Stable Time | ≤10sec |
Overload | 100% F.S. + 9e |
Safety Load | 120% F.S. |
Ultimate Load | 400% F.S. |
Battery | 4*AA 1.5V batteries |
Battery Life | ≥25hour (tested by dedicated batteries) |
Display | 25.4mm (1inch) ultra-bright LED |
Op. Temp. | -10℃ ~ +40℃ |
Op. Humidity | 20℃ ≤90% |
Capacity
Modal | Max. Cap. | Min. Cap. | Res. | Division |
OCS-01-S | 100kg | 1kg | 0.05kg | 2,000 |
OCS-02-S | 200kg | 2kg | 0.1kg | 2,000 |
OCS-03-S | 300kg | 2kg | 0.1kg | 3,000 |
OCS-05-S | 500kg | 4kg | 0.2kg | 2,500 |
OCS-1-S | 1,000kg | 10kg | 0.5kg | 2,000 |
Dimension & Weight
Display & Keys
Scale Keys
Remote Keys
Indicators
Message
Operations
Power On/Off
- Long press
to power-on scale. Scale perform initialization and power-on test
, shows twice, then capacity
shows, battery life percentage
shows, weight detection
shows and then auto zero.
- For information about Auto-Zero, refer to Scale Configuration in Technical Manual.
- Long press
or
to power-off scale. Battery life percentage
shows, off message
shows, and then cut off power.
- When 3 batteries voltage is lower than 3.2V, scale will auto power-off itself. Please replace the dead batteries with new ones.
Zero
- Long press
, or press
, to zero. ZERO shows.
- If load is in motion, or tared, or out of Manual-Zero Range, shows.
- For information about Manual-Zero Range, refer to Scale Configuration in Technical Manual.
Tare In/Out
- In gross mode, press
, or press
, to tare in. TARE shows.
- If load is in motion, or negative, or out of Tare Range,
shows.
- Tare will reduce the apparent overload range of scale. For example, if a 500*0.2kg scale has a 100kg container as its tare, the scale will overload at a new weight of 401.8kg (500 – 100 + additional 9 divisions).
- In net mode, press
, or press
, to tare out. TARE disappears.
Lock/Unlock
- Press
or
to lock screen. HOLD shows.
- Press
or
again to unlock screen. HOLD disappears.
Accumulate
- Press
to accumulate current weight.
shows, indicating weight is accumulated. Scale uses displayed weight, so gross or net weight is added into the same accumulator.
- If load is in motion, or negative, or does not return to zero before,
shows.
View
- Press
to enter View mode.
- Display flashes accumulated weight.
- Press
or
to view high 5-digit or low 5-digit.
- Press
or
to exit View mode.
Delete Last Weight
- Press
to delete last accumulated weight.
shows, indicating last accumulated weight is deleted. Delete function only deletes the last weight.
- If last accumulated weight has been deleted,
shows.
Clear All Weight
- Press
first and then press
to clear all accumulated weight.
shows, indicating all weight is cleared.
Unit Switch
- Long press
or press
, to switch unit in between kg, lb, and User Unit.
- When unit is kg,
shows. When unit is lb,
shows.
- For more information about User Unit, refer to Scale Configuration in Technical Manual.
User Setup
- Press
first and then press
or
to enter User Setup menu.
shows.
Auto-Off Timing
- Press
or
to enter Auto-Off
Timing. shows.
- Press
or press or
,
to change timing value.
- Auto-Off Timing can be set to:0 (disabled),5 (5min),10 (10min),15 (15min),30 (30min),60 (60min). It is disabled by default.
- Auto-Off function maximizes scale’s battery life against people’s carelessness not to power off scale when it’s not working.
- Auto-Off starts countdown timer when there’s no action or load is stable. Any key pressing or motion in load restarts countdown timer.
Display Brightness
- Press
or
to enter Display Brightness.
shows.
- Press
or press
or
, to change brightness value.
- Display Brightness can be set to:
(disabled),1 (dim),2 (normal),3 (bright).
- Dim display brightness saves battery power dramatically.
Idle Mode Timing
- Press
or
to enter Idle Mode Timing.
shows.
- Press
or press
or
, to change timing value.
- Idle Mode Timing can be set to: 0(disabled),5 (5sec),10 (10sec),15 (15sec),30 (30sec),60 (60sec). It is 30sec by default.
- To maximize battery life, scale automatically enters Idle Mode, when there’s no action or the load is stable. In Idle Mode, scale works in low-power consumption status. Any key pressing or motion in load wakes up scale from Idle Mode.
- Press
or
to exit User Setup.
Battery Maintenance
To maximize battery life, please note the following battery maintenance guide.
- This scale is powered by a 4 AA 1.5V batteries.
- Battery houses at the rear of scale can be opened by screwing off screws.
- Depending on display brightness and idle mode setting, normally, battery works over 25 hours.
- In order to conserve battery life, enable Auto-Off and Idle Mode, dim display brightness.
- When 4 batteries voltage is lower than 3.5V, scale will auto power-off itself. Please replace the dead batteries with new ones.
Troubleshooting
Simple problems can be resolved as below listed solution. If problems still exist, please contact your local representative.
Symptom | Possible Cause | Suggested Solution |
not power-on after![]() |
discharged / defective battery | check battery and replace |
defective On/Off key | press harder and keep pressing for 2s |
defective power cable | open front panel, check power cable | |
defective mainboard | contact representative | |
display flashes | discharged battery | replace battery |
no action taken after key pressed | scale is disturbed | re-plug power cable |
defective key | contact representative | |
weight reading not stable | load in motion | keep load stable |
weak Anti-Motion | change Anti-Motion level | |
damped loadcell or mainboard | dry loadcell or mainboard | |
defective mainboard | contact representative | |
weight reading not zero when no load | discharged battery | replace battery |
loadcell stressed too long | hang scale in storage | |
loadcell drifts | contact representative | |
large error in weight reading | scale not zeroed before applying load | Manual Zero scale before loading |
wrong unit | switch to correct unit | |
require calibration | calibrate scale | |
defective loadcell or mainboard | contact representative |
Documents / Resources
![]() |
vetek OCS-S1 High Resolution Digital Crane Scale [pdf] User Manual OCS-S1 High Resolution Digital Crane Scale, OCS-S1, High Resolution Digital Crane Scale, Digital Crane Scale |