  • Accuracy: Chinese GB/T 11883-2002 CIII eqv. OIML R76
  • Tare Range: 100% F.S.
  • Zero Range: 4% F.S.
  • Stable Time: 10 seconds
  • Overload Safety: 100% F.S. + 9e 120% F.S.
  • Load Battery: 18650 lithium battery
  • Battery: DC5V charger
  • Battery Life: >20 hours
  • Display: 115*41mm LED display

Product Usage Instructions

Operation and Maintenance

  • Do NOT overload the scale to avoid damaging the load cell and voiding the warranty.
  • Do NOT leave the load hung on the scale for extended periods as it can decrease accuracy and shorten the load cell’s life.
  • Inspect the shackle, hook, clips, pins, and screws regularly before using the scale.
  • Check the battery frequently and replace dead batteries with new ones promptly.
  • Rotate the load instead of the scale if needed.
  • Avoid using the scale under thunder or rain conditions.
  • Hang the scale on a shelf in a dry and well-ventilated room; do NOT place it directly on the ground.
  • Do NOT attempt to repair the scale yourself; contact your local representative for assistance.
  • Use only the original DC5V charger; do NOT use external chargers.

FAQ

  • Q: How do I change the Auto-Off Timing on the scale?
    A: Press the corresponding keys as described in the User Setup section to access the Auto-Off Timing setting. Then, use the provided instructions to change the timing value to your desired setting.
  • Q: What is the default Idle Mode Timing setting for the scale?
    A: The default Idle Mode Timing setting is 30 seconds. You can adjust this setting using the instructions provided in the User Setup section.

User Guide
For good performance and precise measurement, be careful with daily operation and maintenance.

  • Do NOT overload scale. This will damage loadcell and void warranty.
  • Do NOT leave load hung on the scale for long. This will decrease scale’s accuracy and shorten loadcell’s life.
  • Inspect shackle and hook before using. Check clips, pins and screws regularly.
  • Check battery frequently. When scale runs out of power, replace the dead batteries with new ones.
  • Rotate load rather than scale if needed.
  • Do NOT use scale under thunder or rain.
  • Hang scale on shelf in dry and well-ventilated room. Do NOT  place scale on the ground directly.
  • Do NOT attempt to repair scale yourself. Contact your local representative.
  • Do NOT use external chargers, Use the original DC5V charger.

Specifications

Accuracy Chinese GB/T 11883-2002 CIII eqv. OIML R76
Tare Range 100% F.S.
Zero Range 4% F.S.
Stable Time ≤10sec
Overload 100% F.S. + 9e
Safety Load 120% F.S.
Battery 18650 lithium battery     DC5V charger
Battery Life >20hour
Display 115*41mm LED display
  • Op. Temp.
    • -10℃ ~ +40℃

Display & Keys

Key Name Function
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (1)
On/Off Power-on Power-off
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (2) Zero Zero
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (3) Hold Lock/unlock
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (4) Tare Tare in/out

Remote Keys

Key Name Function
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (5)
Zero Zero: Change digit
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (6)  Tare Tare in/out: Move digit
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7)  Hold Lock or unlock: Confirm & Next
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (8)
Acc. 2nd function: Change digit
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7)  Del. 2nd function: Move digit
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (1) F1 2nd function
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (2) F2 Unit Switch
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (12) Off Long press to power off
VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (13) 2nd 2nd function

User Setup

Press VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (13) first then press  VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7)to enter User Setup menu. shows.

Auto-Off Timing

  • PressVETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7)  to enter Auto-Off Timing.  OFF– shows.
  •  Press VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (5) or VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (8) to change timing value.
  • Auto-Off Timing can be set to: 0 (disabled), 5 (5min),10 (10min), 15 (15min), 30 (30min), 60 (60min).

Display Brightness

  • Press   VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7) to enter Backlight Brightness. br— shows.
  • Press  VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (5) or VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (8) to change brightness value.
  • Display Brightness can be set to 0-7 levels.

Idle Mode Timing

  • Press VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7) to enter Idle Mode Timing. idE— shows
  • Press  VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (5) or VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (8) to change timing value.
  • Idle  VETEK-OCS-V-High-Resolution-Digital-Crane-Scale- (7) Mode Timing can be set to: 0(disabled), 5(5sec), 10(10sec), 15(15sec), 30(30sec), 60 (60sec). It is 30sec by default.