Braking setting functions

TOSHIBA TOSVERT Transistor Inverter - icon : Braking mode selection
: Release frequency
: Release time
: Creeping frequency
: Creeping time

Function

Setting functions to control braking timing.
Parameter setting for braking setting function

Title Function Setting range Default settin
TOSHIBA TOSVERT Transistor Inverter - icon1 Braking mode selection 0: Disabled
1:Enabled (forward run)
2:Enabled (reverse run)
3:Enabled (operating direction)
0
TOSHIBA TOSVERT Transistor Inverter - icon2 Release frequency TOSHIBA TOSVERT Transistor Inverter - icon7– 20.0 [Hz] 3.0
TOSHIBA TOSVERT Transistor Inverter - icon3 Release time 0.00 – 2.50 [s] 0.05
TOSHIBA TOSVERT Transistor Inverter - icon4 Creeping frequency TOSHIBA TOSVERT Transistor Inverter - icon7 – 20.0 [Hz] 3.0
TOSHIBA TOSVERT Transistor Inverter - icon5 Creeping time 0.00 – 2.50 [s] 0.10
Title Function Setting range Setting value
TOSHIBA TOSVERT Transistor Inverter - icon6 Output terminal selection 1A
(RY-RC)
0 – 255 46:BR (Braking sequence output)
or
47:BRN (Inversion of braking sequence output)

Note) In case of others output terminal, it is deferent from parameter title.
RY-RC: TOSHIBA TOSVERT Transistor Inverter - icon9
FLA-FLB-FLC: TOSHIBA TOSVERT Transistor Inverter - icon10
Explanation of braking setting function
At starting the motor:
When the operation signal is ‘ON’, the brake release signal is ‘ON’ after getting the flux of magnetic induction before brake releasing.
The output torque of inverter is generated before the brake is released by outputting ‘the frequency of the TOSHIBA TOSVERT Transistor Inverter - icon11 setting’ to ‘the direction of the TOSHIBA TOSVERT Transistor Inverter - icon12 setting’.
The motor is able to accelerate smoothly at the same time as releasing the brake because TOSHIBA TOSVERT Transistor Inverter - icon13function provides ‘the delay of acceleration beginning ‘.
At stop the motor:
When the operation signal is ‘OFF’, the brake close signal is ‘ON’ after reaching the creeping frequency of TOSHIBA TOSVERT Transistor Inverter - icon14 setting. After that, the VF-S11 outputs creeping frequency while setting time of TOSHIBA TOSVERT Transistor Inverter - icon15, and stops after delayed time of mechanical brake.
TOSHIBA TOSVERT Transistor Inverter - icon31 Braking mode selection
0: Disabled
1: Enabled (forward run)
The rise operation is forward rotation of motor at RISE/DESCENT action.
The direction of inverter output frequency (TOSHIBA TOSVERT Transistor Inverter - icon30) is forward direction regardless of FORWARD/REVERSE drive.
2: Enabled (reverse run)
The rise operation is reverse rotation of motor at RISE/DESCENT action.
The direction of inverter output frequency (TOSHIBA TOSVERT Transistor Inverter - icon30) is reverse direction regardless of FORWARD/REVERSE drive.
3: Enabled (operating direction)
This value is for the horizontal operation.
The direction of inverter output frequency (TOSHIBA TOSVERT Transistor Inverter - icon30) is same as direction of drive.
TOSHIBA TOSVERT Transistor Inverter - icon30 Release frequency
The inverter outputs TOSHIBA TOSVERT Transistor Inverter - icon30‘s frequency to TOSHIBA TOSVERT Transistor Inverter - icon1‘s direction. This function is for generating motor torque by slipping of the restrained motor. By this, the motor starts smoothly when the brake is released.
TheTOSHIBA TOSVERT Transistor Inverter - icon30 setting value depends on load condition. The standard setting is ‘the slipping frequency’ at rated output of applied motor.
TOSHIBA TOSVERT Transistor Inverter - icon33 Release time
The release time is time to maintain frequency ofTOSHIBA TOSVERT Transistor Inverter - icon33 setting at start.
The standard setting is delayed time of mechanical brake.
TOSHIBA TOSVERT Transistor Inverter - icon26 Creeping frequency
The ‘close brake signal’ outputs TOSHIBA TOSVERT Transistor Inverter - icon26‘s frequency while TOSHIBA TOSVERT Transistor Inverter - icon23‘s setting time at stop.
The TOSHIBA TOSVERT Transistor Inverter - icon26 setting value depends on load condition. The standard setting is
The TOSHIBA TOSVERT Transistor Inverter - icon26 setting value depends on load condition. The standard setting is ‘the slipping frequency’ at rated output of applied motor
TOSHIBA TOSVERT Transistor Inverter - icon25 Creeping time
The creeping time is time to maintain frequency of TOSHIBA TOSVERT Transistor Inverter - icon26.
The standard setting is a little more than delayed time of mechanical brake.

TOSHIBA TOSVERT Transistor Inverter - 1

Toshiba Schneider Inverter Corporation
The technical information in this manual is provided to explain the principal functions and applications of the product, but not to grant you a license to use the intellectual property or any other property of Toshiba Schneider Inverter Corporation or a third party.

TOSHIBA logo© Toshiba Schneider Inverter Corporation 2006
All rights reserved.

Documents / Resources

TOSHIBA TOSVERT Transistor Inverter [pdf] User Guide
TOSVERT Transistor Inverter, TOSVERT, Transistor Inverter, Inverter

References

Leave a comment

Your email address will not be published. Required fields are marked *