Sensata-Technologies-LOGO

Sensata Technologies THK5 Absolute Rotary Encoder

Sensata-Technologies-THK5-Absolute-Rotary-Encoder

ELECTRICAL INSTALLATION

BF : Connector M12 5 pins (Device class B)

Pin number Description Illustration
1 L+ : power supply V+ Sensata-Technologies-THK5-Absolute-Rotary-Encoder-1
2 N.C.
3 L- : power supply gnd
4 IO-Link
5 N.C.

Device specification

Specification IO-Link description Value
Transfer rate COM3 230.4 kBaud
Minimum cycle time of device Minimum cycle time 0x0A (1ms)
Frame specification M-Sequence Capability: TYPE_1_2 TYPE_2_V

Supported

Amount of preoperate data required M-Sequence Type Preoperate
Amount of operate data required M-Sequence Type Operate
Enhanced parameters ISDU supported
IO-Link protocol version Revision ID 0x11 (Version 1.1)
Amount of process data from the device to the master to the device ProcessDataIn 0x85 (6 bytes)
Amount of process data from the master ProcessDataOut 0x00 (0 byte)
Manufacturer ID Vendor ID 0x0468 (1128)
Device identification Device ID 0x0006

Process data

Sensata-Technologies-THK5-Absolute-Rotary-Encoder-2

When the absolute position resolution is configured to a value smaller than 14 bits, the data is aligned to the right on the bit 2.
For example, if the absolute position resolution (index 90) is configured to 12 bits, the bits 2 to 13 will contain the data. Bits 14 and 15 will then be unused and set to zero.

Standard Identification data

Index (hex) Sub index Name Data type Access Contents
16 (0x10) 0 Vendor Name StringT RO BEI Sensors
17 (0x11) 0 Vendor Text StringT RO Sensata Technologies Inc.
18 (0x12) 0 Product Name StringT RO THx5-ZIO
19 (0x13) 0 Product ID StringT RO Detailed reference
20 (0x14) 0 Product Text StringT RO Absolute multiturn encoder
21 (0x15) 0 Serial Number StringT RO Unique number
22 (0x16) 0 Hardware Version StringT RO 284v3
23 (0x17) 0 Firmware Version StringT RO V1.2
24 (0x18) 0 Application Specific Tag StringT RW ***

System command

Index (hex) Subindex Name Data type Access Value range
2 (0x02) 0 System-Command UIntegerT 8 WO 130 (0x82) : Restore factory settings
131 (0x83) : Back-to-Box command

Observation parameters

Index (hex) Subindex Name Data type Access Value range Comment
 

 

 

 

40 (0x28)

0 Process Data Input Record RO    
1 Speed IntegerT16 NA -10000 to 10000 Speed value.
2 Multiturn counter UIntegerT16 NA 0 to 65535 Number of complete turns
3 Position UIntegerT14 NA 0 to 16383 Single-turn position
4 Absolute position error BooleanT NA 0 or 1 Multi turn position status
5 Magnetic field issue BooleanT NA 0 or 1 Magnetic field status

Diagnosis, Observer and Maintenance access

Index (hex) Subindex Name Data type Access Value range Comment
 

 

36 (0x24)

 

 

0

 

 

Device Status

 

 

UIntegerT 8

 

 

RO

 

 

0 to 4

Device status : Device is OK [0]

Maintenance required [1] Out of specification [2] Functional check [3]

Failure [4]

110 (0x6E) 0 Operating hours UIntegerT 32 RO 0 to 4294967295 Number of hours with device on

Sensata specific parameters, Observer and Maintenance access

Index Subindex Name Data type Access Value range Comment
64 (0x40) 0 Set Zero Point Button WO Set zero as current position
65 (0x41) 0 Apply Preset Button WO Apply preset values as the current position
67 (0x43) 0 Preset singleturn UIntegerT14 RW 0 to 16383 Preset value for position inside the turn
68 (0x44) 0 Preset multiturn UIntegerT16 RW 0 to 65535 Preset value for the number of turns
72 (0x48) 0 Rotation direction BooleanT RW 0  : CW

1  : CCW

Set the rotation direction
 

80 (0x50)

 

0

Speed calculation window  

UIntegerT8

 

RW

0 : 20 ms

1 : 200 ms

2 : 600 ms

Time between each speed data update
90 (0x5A) 0 Singleturn Resolution UIntegerT8 RW 1 to 14 bits Power of 2, number of bits
91 (0x5B) 0 Multiturn Resolution UIntegerT8 RW 1 to 16 bits Power of 2, number of bits

Sensata specific parameters, Specialist access

Index Subindex Name Data format Access Value range Comment
 

252 (0xFC)

 

0

 

Test parameter 252

 

UIntegerT 8

 

RW

0  : A appears

1  : A disappears 2 : B appears

3 : B disappears

 

Do not use

For IO-link test purpose.

Factory settings parameters

Name Index Factory Setting Comment
Application Specific Tag 24 *** Customer text tag (string 32 characters)
Rotation direction 72 0 : CW Set the rotation direction
Singleturn Resolution 90 12 bits Resolution of the single-turn counter (in bits)
Multiturn Resolution 91 16 bits Resolution of the multi-turn counter (in bits)
Speed calculation window 80 1 : 200ms Time between each speed data update
Preset singleturn 67 0 Preset value for position inside the turn
Preset multiturn 68 0 Preset value for the number of turns
Operating-hours 110 0 Number of hours with device on

Events

Code Name Type Comment
16912 (0x4210) Temperature issue Warning event appears when temperature exceeds specifications.
 

6145 (0x1801)

Off-power multi-turn counter desynchronized with running multi-turn counter  

Warning

Device off-power MT counter is desynchronized with running MT.

Set Zero or set Preset needs to be done

16912 (0x5012) Battery low Warning Device needs to be replaced, the multi-turn position will be lost when power is off
35888 (0x8C30) Test Event A Error Event appears by setting index 252 to value 1, Event disappears by setting index 252 to value 2
36351 (0x8DFF) Test Event B Error Event appears by setting index 252 to value 3, Event disappears by setting index 252 to value 4

 

Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata
products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation,and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice.

Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE,EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF.
All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR

APPLICATIONS
ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA

CONTACT US

Americas
+1 (800) 350 2727
sensors@sensata.com
Europe, Middle East & Africa
+33 (3) 88 20 8080
position-info.eu@sensata.com

Asia Pacific
sales.isasia@list.sensata.com
China +86 (21) 2306 1500
Japan +81 (45) 277 7117
Korea +82 (31) 601 2004
India +91 (80) 67920890
Rest of Asia +886 (2) 27602006
ext 2808

Documents / Resources

Sensata Technologies THK5 Absolute Rotary Encoder [pdf] Instruction Manual
THK5, THM5, Absolute Rotary Encoder, Rotary Encoder, Absolute Encoder, Encoder

References

Leave a comment

Your email address will not be published. Required fields are marked *