INSTALLATION GUIDE
|THX5 IO-LINK OPERATING INSTRUCTIONS ­ FIRMWARE V1.2

ELECTRICAL INSTALLATION

BF : Connector M12 5 pins (Device class B)

Pin number 1 2 3 4 5

Description L+ : power supply V+
N.C. L- : power supply gnd
IO-Link N.C.

Illustration

IO-LINK SPECIFICATION INFORMATION

Device specification
Specification Transfer rate Minimum cycle time of device Frame specification Amount of preoperate data required Amount of operate data required Enhanced parameters IO-Link protocol version Amount of process data from the device to the master to the device Amount of process data from the master Manufacturer ID Device identification

IO-Link description COM3 Minimum cycle time M-Sequence Capability: M-Sequence Type Preoperate M-Sequence Type Operate ISDU supported Revision ID ProcessDataIn ProcessDataOut Vendor ID Device ID

Value 230.4 kBaud 0x0A (1ms)
TYPE_1_2 TYPE_2_V Supported
0x11 (Version 1.1) 0x85 (6 bytes) 0x00 (0 byte) 0x0468 (1128) 0x0006

Process data Name Speed Multiturn Position
Flag2
Flag1

Description Rotating speed Multiturn counter Absolute position counter Absolute position error True: The multiturn counter cannot be trusted
Cleared after set Zero, Apply Preset or Restore Factory Settings command Magnetic field issue
Problem with the sensor

Datatype Bitoffset Bitlength Value Range

Unit

IntegerT

32

16

-12000 to 12000 rpm

UIntegerT

16

16

0 to 65535

turns

UIntegerT

2

14

0 to 16383

BooleanT

1

true false

BooleanT

0

true false

When the absolute position resolution is configured to a value smaller than 14 bits, the data is aligned to the right on the bit 2. For example, if the absolute position resolution (index 90) is configured to 12 bits, the bits 2 to 13 will contain the data. Bits 14 and 15 will then be unused and set to zero.
Page 1

Copyright © 2022 Sensata Technologies, Inc.

www.sensata.com

Standard Identification data

Index (hex) 16 (0x10) 17 (0x11) 18 (0x12) 19 (0x13) 20 (0x14) 21 (0x15) 22 (0x16) 23 (0x17) 24 (0x18)

Sub index 0 0 0 0 0 0 0 0 0

Name Vendor Name Vendor Text Product Name
Product ID Product Text Serial Number Hardware Version Firmware Version Application Specific Tag

Data type StringT StringT StringT StringT StringT StringT StringT StringT StringT

Access RO RO RO RO RO RO RO RO RW

System command

Index (hex) Subindex

Name

Data type Access

2 (0x02)

0

System-Command UIntegerT 8 WO

Contents BEI Sensors Sensata Technologies Inc. THx5-ZIO Detailed reference Absolute multiturn encoder Unique number
284v3 V1.2 ***
Value range 130 (0x82) : Restore factory settings 131 (0x83) : Back-to-Box command

Observation parameters

Index (hex) 40 (0x28)

Subindex 0 1 2 3 4
5

Name Process Data
Input Speed Multiturn counter Position Absolute position error Magnetic field issue

Data type Record
IntegerT16 UIntegerT16 UIntegerT14
BooleanT
BooleanT

Access Value range

RO

NA -10000 to 10000

NA

0 to 65535

NA

0 to 16383

NA

0 or 1

NA

0 or 1

Comment
Speed value. Number of complete turns
Single-turn position Multi turn position status
Magnetic field status

Diagnosis, Observer and Maintenance access

Index (hex) Subindex

36 (0x24)

0

110 (0x6E)

0

Name Device Status Operating hours

Data type UIntegerT 8 UIntegerT 32

Access RO RO

Value range 0 to 4
0 to 4294967295

Comment
Device status : Device is OK [0] Maintenance required [1] Out of specification [2] Functional check [3]
Failure [4]
Number of hours with device on

Sensata specific parameters, Observer and Maintenance access

Index Subindex

Name

Data type Access Value range

Comment

64 (0x40)

0

Set Zero Point

Button

WO

-

Set zero as current position

65 (0x41)

0

Apply Preset

Button

WO

-

Apply preset values as the current position

67 (0x43)

0

Preset singleturn UIntegerT14 RW

0 to 16383

Preset value for position inside the turn

68 (0x44)

0

Preset multiturn UIntegerT16 RW

0 to 65535

Preset value for the number of turns

72 (0x48)

0

Rotation direction BooleanT

RW

0 : CW 1 : CCW

Set the rotation direction

80 (0x50)

0

Speed calculation window

UIntegerT8

RW

0 : 20 ms 1 : 200 ms 2 : 600 ms

Time between each speed data update

90 (0x5A)

0

Singleturn Resolution

UIntegerT8 RW 1 to 14 bits

Power of 2, number of bits

91 (0x5B)

0

Multiturn Resolution

UIntegerT8 RW 1 to 16 bits

Power of 2, number of bits

Page 2

Copyright © 2022 Sensata Technologies, Inc.

www.sensata.com

Sensata specific parameters, Specialist access

Index 252 (0xFC)

Subindex 0

Name
Test parameter 252

Data format UIntegerT 8

Access RW

Value range
0 : A appears 1 : A disappears 2 : B appears 3 : B disappears

Comment
Do not use For IO-link test purpose.

Factory settings parameters
Name Application Specific Tag
Rotation direction Singleturn Resolution Multiturn Resolution Speed calculation window
Preset singleturn Preset multiturn Operating-hours

Index 24 72 90 91 80 67 68 110

Factory Setting ***
0 : CW 12 bits 16 bits 1 : 200ms
0 0 0

Comment Customer text tag (string 32 characters)
Set the rotation direction Resolution of the single-turn counter (in bits) Resolution of the multi-turn counter (in bits)
Time between each speed data update Preset value for position inside the turn
Preset value for the number of turns Number of hours with device on

Events Code
16912 (0x4210)
6145 (0x1801)
16912 (0x5012) 35888 (0x8C30) 36351 (0x8DFF)

Name Temperature issue Off-power multi-turn counter desynchronized with running multi-turn
counter Battery low
Test Event A
Test Event B

Type Warning
Warning
Warning Error Error

Comment event appears when temperature exceeds
specifications.
Device off-power MT counter is desynchronized with running MT.
Set Zero or set Preset needs to be done
Device needs to be replaced, the multi-turn position will be lost when power is off
Event appears by setting index 252 to value 1, Event disappears by setting index 252 to value 2 Event appears by setting index 252 to value 3, Event disappears by setting index 252 to value 4

Sensata Technologies, Inc. ("Sensata") data sheets are solely intended to assist designers ("Buyers") who are developing systems that incorporate Sensata products (also referred to herein as "components"). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer's systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED "AS IS". SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata's terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS' PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA

Copyright © 2022 Sensata Technologies, Inc.

Rev. 05/19/2022

Page 3
CONTACT US
Americas +1 (800) 350 2727 sensors@sensata.com Europe, Middle East & Africa +33 (3) 88 20 8080 position-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808