ELECTRICAL INSTALLATION
BF : Connector M12 5 pins (Device class B)
Pin number | Description | Illustration |
1 | L+ : power supply V+ | ![]() |
2 | N.C. | |
3 | L- : power supply gnd | |
4 | IO-Link | |
5 | N.C. |
Device specification
Specification | IO-Link description | Value |
Transfer rate | COM3 | 230.4 kBaud |
Minimum cycle time of device | Minimum cycle time | 0x0A (1ms) |
Frame specification | M-Sequence Capability: | TYPE_1_2 TYPE_2_V
Supported |
Amount of preoperate data required | M-Sequence Type Preoperate | |
Amount of operate data required | M-Sequence Type Operate | |
Enhanced parameters | ISDU supported | |
IO-Link protocol version | Revision ID | 0x11 (Version 1.1) |
Amount of process data from the device to the master to the device | ProcessDataIn | 0x85 (6 bytes) |
Amount of process data from the master | ProcessDataOut | 0x00 (0 byte) |
Manufacturer ID | Vendor ID | 0x0468 (1128) |
Device identification | Device ID | 0x0006 |
Process data
When the absolute position resolution is configured to a value smaller than 14 bits, the data is aligned to the right on the bit 2.
For example, if the absolute position resolution (index 90) is configured to 12 bits, the bits 2 to 13 will contain the data. Bits 14 and 15 will then be unused and set to zero.
Standard Identification data
Index (hex) | Sub index | Name | Data type | Access | Contents |
16 (0x10) | 0 | Vendor Name | StringT | RO | BEI Sensors |
17 (0x11) | 0 | Vendor Text | StringT | RO | Sensata Technologies Inc. |
18 (0x12) | 0 | Product Name | StringT | RO | THx5-ZIO |
19 (0x13) | 0 | Product ID | StringT | RO | Detailed reference |
20 (0x14) | 0 | Product Text | StringT | RO | Absolute multiturn encoder |
21 (0x15) | 0 | Serial Number | StringT | RO | Unique number |
22 (0x16) | 0 | Hardware Version | StringT | RO | 284v3 |
23 (0x17) | 0 | Firmware Version | StringT | RO | V1.2 |
24 (0x18) | 0 | Application Specific Tag | StringT | RW | *** |
System command
Index (hex) | Subindex | Name | Data type | Access | Value range |
2 (0x02) | 0 | System-Command | UIntegerT 8 | WO | 130 (0x82) : Restore factory settings |
131 (0x83) : Back-to-Box command |
Observation parameters
Index (hex) | Subindex | Name | Data type | Access | Value range | Comment |
40 (0x28) |
0 | Process Data Input | Record | RO | ||
1 | Speed | IntegerT16 | NA | -10000 to 10000 | Speed value. | |
2 | Multiturn counter | UIntegerT16 | NA | 0 to 65535 | Number of complete turns | |
3 | Position | UIntegerT14 | NA | 0 to 16383 | Single-turn position | |
4 | Absolute position error | BooleanT | NA | 0 or 1 | Multi turn position status | |
5 | Magnetic field issue | BooleanT | NA | 0 or 1 | Magnetic field status |
Diagnosis, Observer and Maintenance access
Index (hex) | Subindex | Name | Data type | Access | Value range | Comment |
36 (0x24) |
0 |
Device Status |
UIntegerT 8 |
RO |
0 to 4 |
Device status : Device is OK [0]
Maintenance required [1] Out of specification [2] Functional check [3] Failure [4] |
110 (0x6E) | 0 | Operating hours | UIntegerT 32 | RO | 0 to 4294967295 | Number of hours with device on |
Sensata specific parameters, Observer and Maintenance access
Index | Subindex | Name | Data type | Access | Value range | Comment |
64 (0x40) | 0 | Set Zero Point | Button | WO | – | Set zero as current position |
65 (0x41) | 0 | Apply Preset | Button | WO | – | Apply preset values as the current position |
67 (0x43) | 0 | Preset singleturn | UIntegerT14 | RW | 0 to 16383 | Preset value for position inside the turn |
68 (0x44) | 0 | Preset multiturn | UIntegerT16 | RW | 0 to 65535 | Preset value for the number of turns |
72 (0x48) | 0 | Rotation direction | BooleanT | RW | 0 : CW
1 : CCW |
Set the rotation direction |
80 (0x50) |
0 |
Speed calculation window |
UIntegerT8 |
RW |
0 : 20 ms
1 : 200 ms 2 : 600 ms |
Time between each speed data update |
90 (0x5A) | 0 | Singleturn Resolution | UIntegerT8 | RW | 1 to 14 bits | Power of 2, number of bits |
91 (0x5B) | 0 | Multiturn Resolution | UIntegerT8 | RW | 1 to 16 bits | Power of 2, number of bits |
Sensata specific parameters, Specialist access
Index | Subindex | Name | Data format | Access | Value range | Comment |
252 (0xFC) |
0 |
Test parameter 252 |
UIntegerT 8 |
RW |
0 : A appears
1 : A disappears 2 : B appears 3 : B disappears |
Do not use For IO-link test purpose. |
Factory settings parameters
Name | Index | Factory Setting | Comment |
Application Specific Tag | 24 | *** | Customer text tag (string 32 characters) |
Rotation direction | 72 | 0 : CW | Set the rotation direction |
Singleturn Resolution | 90 | 12 bits | Resolution of the single-turn counter (in bits) |
Multiturn Resolution | 91 | 16 bits | Resolution of the multi-turn counter (in bits) |
Speed calculation window | 80 | 1 : 200ms | Time between each speed data update |
Preset singleturn | 67 | 0 | Preset value for position inside the turn |
Preset multiturn | 68 | 0 | Preset value for the number of turns |
Operating-hours | 110 | 0 | Number of hours with device on |
Events
Code | Name | Type | Comment |
16912 (0x4210) | Temperature issue | Warning | event appears when temperature exceeds specifications. |
6145 (0x1801) |
Off-power multi-turn counter desynchronized with running multi-turn counter |
Warning |
Device off-power MT counter is desynchronized with running MT.
Set Zero or set Preset needs to be done |
16912 (0x5012) | Battery low | Warning | Device needs to be replaced, the multi-turn position will be lost when power is off |
35888 (0x8C30) | Test Event A | Error | Event appears by setting index 252 to value 1, Event disappears by setting index 252 to value 2 |
36351 (0x8DFF) | Test Event B | Error | Event appears by setting index 252 to value 3, Event disappears by setting index 252 to value 4 |
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata
products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation,and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice.
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE,EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF.
All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR
APPLICATIONS
ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA
CONTACT US
Americas
+1 (800) 350 2727
sensors@sensata.com
Europe, Middle East & Africa
+33 (3) 88 20 8080
position-info.eu@sensata.com
Asia Pacific
sales.isasia@list.sensata.com
China +86 (21) 2306 1500
Japan +81 (45) 277 7117
Korea +82 (31) 601 2004
India +91 (80) 67920890
Rest of Asia +886 (2) 27602006
ext 2808
Documents / Resources
![]() |
Sensata Technologies THK5 Absolute Rotary Encoder [pdf] Instruction Manual THK5, THM5, Absolute Rotary Encoder, Rotary Encoder, Absolute Encoder, Encoder |