SellEton logoScales.com
User ManualSellEton SL 910X Remote DisplaySL-910X Remote Display
USER’S MANUAL
NOV 2023
www.selletonscales.com

FEATURES

  • Connects to your indicator to display live weight on a larger screen
  • Bright LED display is readable in high and low light
  • Display turns green when weight is stable and red when unstable
  • 6 digit display
  • Painted metal construction
  • For indoor or outdoor use
  • Includes two mounting brackets
  • Connects to most indicators
  • Ideal for use with vehicle scales, so drivers can see the weight from inside their vehicle, and proceed once the weight is green/stable
  • Easy to install, connects with RS232 port

MOUNTING DIMENSIONS

SellEton SL 910X Remote Display - MOUNTING DIMENSIONS

CONNECTOR

SellEton SL 910X Remote Display - CONNECTOR

SET-UP EXAMPLE

Here is an example of how to pair your scoreboard to SellEton’s most popular indicators. To set up SL-910X remote display, parameter settings need to be changed on your SL-7510 or SL-7516 indicator to allow communication between the two devices.

SL-7510 PARAMETER SETTINGS
To enter parameter settings, follow the procedure below:

  1. Press and hold the HOLD and PRINT key at the same time for 2 seconds
  2. Use the arrow keys to change C01 to C18
  3. Press the PRINT SellEton SL 910X Remote Display - Symbols key to enter/edit the parameter setting
  4. Use the arrow keys to change the settings of the below parameters
  5. Press the ACCUM key to save and exit parameter settings

SL-7516 PARAMETER SETTINGS
To enter calibration/parameter settings, follow the procedure below:

  1. Press and hold the ON/OFF and SET key at the same time for 2 seconds
  2. Use the arrow keys to change C01 to C18
  3. Press the SET SellEton SL 910X Remote Display - Symbols key to enter/edit the parameter setting
  4. Use the arrow keys to change the settings of the below parameters
  5. Press the ON/OFF key to save and exit parameter settings
Function Parameter Settings/Options
Communication Setting C18 Set the serial interface data output method:
0 = Turn off serial interface data output
1 = Continuous sending mode, for remote display
2 = Print mode, for ticket printer
3 = Command request mode, connect computer.
4 = PC continuous sending mode, connect computer
Baud Rate C19 0=1200
1=2400
2=4800
3=9600 (SL-910X remote display)

For more help, contact us at: 844-735-5386
Remote Display Continuous Sending Mode
Note: Baud Rate must be set to 9600SellEton SL 910X Remote Display - Remote Display

State A

Bits0,1,2

0 1 2 Decimal point position
1 0 0 XXXXXX0
0 1 0 XXXXXXX
1 1 0 XXXXX.X
0 0 1 XXXX.XX
1 0 1 XXX.XXX

Bits3,4

Division
0 1 X1
1 0 X2

State B

BitsS function
Bits0 gross=0, net=1
Bits1 Symbol: positive=0, negative=1
Bits2 Overload (or under zero)=1
Bits3 dynamic=1
Bits4 unit: lb=0, kg=1
Bits5 Constant 1
Bits6 Constant 0

State C

Bit2 Bit1 Bit0 unit
0 0 0 Kg or lb
0 0 1 g
0 1 0 t
Bit 3 printing=1
Bit 4 Extend display=1
Bit 5 Constant 1
Bit 6 Constant 0

SellEton logo