Scales.com
User ManualSL-910X Remote Display
USER’S MANUAL
NOV 2023
www.selletonscales.com
FEATURES
- Connects to your indicator to display live weight on a larger screen
- Bright LED display is readable in high and low light
- Display turns green when weight is stable and red when unstable
- 6 digit display
- Painted metal construction
- For indoor or outdoor use
- Includes two mounting brackets
- Connects to most indicators
- Ideal for use with vehicle scales, so drivers can see the weight from inside their vehicle, and proceed once the weight is green/stable
- Easy to install, connects with RS232 port
MOUNTING DIMENSIONS
CONNECTOR
SET-UP EXAMPLE
Here is an example of how to pair your scoreboard to SellEton’s most popular indicators. To set up SL-910X remote display, parameter settings need to be changed on your SL-7510 or SL-7516 indicator to allow communication between the two devices.
SL-7510 PARAMETER SETTINGS
To enter parameter settings, follow the procedure below:
- Press and hold the HOLD and PRINT key at the same time for 2 seconds
- Use the arrow keys to change C01 to C18
- Press the PRINT
key to enter/edit the parameter setting
- Use the arrow keys to change the settings of the below parameters
- Press the ACCUM key to save and exit parameter settings
SL-7516 PARAMETER SETTINGS
To enter calibration/parameter settings, follow the procedure below:
- Press and hold the ON/OFF and SET key at the same time for 2 seconds
- Use the arrow keys to change C01 to C18
- Press the SET
key to enter/edit the parameter setting
- Use the arrow keys to change the settings of the below parameters
- Press the ON/OFF key to save and exit parameter settings
Function | Parameter | Settings/Options |
Communication Setting | C18 | Set the serial interface data output method: 0 = Turn off serial interface data output 1 = Continuous sending mode, for remote display 2 = Print mode, for ticket printer 3 = Command request mode, connect computer. 4 = PC continuous sending mode, connect computer |
Baud Rate | C19 | 0=1200 1=2400 2=4800 3=9600 (SL-910X remote display) |
For more help, contact us at: 844-735-5386
Remote Display Continuous Sending Mode
Note: Baud Rate must be set to 9600
State A |
|||
Bits0,1,2 |
|||
0 | 1 | 2 | Decimal point position |
1 | 0 | 0 | XXXXXX0 |
0 | 1 | 0 | XXXXXXX |
1 | 1 | 0 | XXXXX.X |
0 | 0 | 1 | XXXX.XX |
1 | 0 | 1 | XXX.XXX |
Bits3,4 |
Division | ||
0 | 1 | X1 | |
1 | 0 | X2 |
State B |
|
BitsS | function |
Bits0 | gross=0, net=1 |
Bits1 | Symbol: positive=0, negative=1 |
Bits2 | Overload (or under zero)=1 |
Bits3 | dynamic=1 |
Bits4 | unit: lb=0, kg=1 |
Bits5 | Constant 1 |
Bits6 | Constant 0 |
State C |
|||
Bit2 | Bit1 | Bit0 | unit |
0 | 0 | 0 | Kg or lb |
0 | 0 | 1 | g |
0 | 1 | 0 | t |
Bit 3 | printing=1 | ||
Bit 4 | Extend display=1 | ||
Bit 5 | Constant 1 | ||
Bit 6 | Constant 0 |
Documents / Resources
![]() |
SellEton SL-910X Remote Display [pdf] User Manual SL-910X Remote Display, SL-910X, Remote Display, Display |