User Manual for SellEton models including: SL-910X Remote Display, SL-910X, Remote Display, Display
Manuals & How To Guides — SellEton Scales
SL-910X Remote Display USER'S MANUAL NOV 2023 www.selletonscales.com FEATURES · Connects to your indicator to display live weight on a larger screen · Bright LED display is readable in high and low light · Display turns green when weight is stable and red when unstable · 6 digit display · Painted metal construction · For indoor or outdoor use · Includes two mounting brackets · Connects to most indicators · Ideal for use with vehicle scales, so drivers can see the weight from inside their vehicle, and proceed once the weight is green/stable · Easy to install, connects with RS232 port MOUNTING DIMENSIONS 33.25" 6.75" 7.5" CONNECTOR Black/Green Ground White TX 4 1 3 2 Red Recieve SET-UP EXAMPLE Here is an example of how to pair your scoreboard to SellEton's most popular indicators. To set up SL-910X remote display, parameter settings need to be changed on your SL-7510 or SL-7516 indicator to allow communication between the two devices. SL-7510 PARAMETER SETTINGS To enter parameter settings, follow the procedure below: 1. Press and hold the HOLD and PRINT key at the same time for 2 seconds 2. Use the arrow keys to change C01 to C18 3. Press the PRINT key to enter/edit the parameter setting 4. Use the arrow keys to change the settings of the below parameters 5. Press the ACCUM key to save and exit parameter settings SL-7516 PARAMETER SETTINGS To enter calibration/parameter settings, follow the procedure below: 1. Press and hold the ON/OFF and SET key at the same time for 2 seconds 2. Use the arrow keys to change C01 to C18 3. Press the SET key to enter/edit the parameter setting 4. Use the arrow keys to change the settings of the below parameters 5. Press the ON/OFF key to save and exit parameter settings Function Parameter Settings/Options Communication Setting C18 Baud Rate C19 Set the serial interface data output method: 0 = Turn off serial interface data output 1 = Continuous sending mode, for remote display 2 = Print mode, for ticket printer 3 = Command request mode, connect computer. 4 = PC continuous sending mode, connect computer 0=1200 1=2400 2=4800 3=9600 (SL-910X remote display) For more help, contact us at: 844-735-5386 Remote Display Continuous Sending Mode Note: Baud Rate must be set to 9600 Output Continuous Format SSSS T WWW X XABC X X X X X X X X X X X C R C K S 1 2 3 4 56 0 1 0 1 0 1 0 1 State A Bits0,1,2 1 2 0 1 1 0 0 Bits3,4 0 0 0 1 1 1 0 Decimal point position XXXXXX0 XXXXXXX XXXXX.X XXXX.XX XXX.XXX Division X1 X2 BitsS Bits0 Bits1 Bits2 Bits3 Bits4 Bits5 Bits6 State B function gross=0, net=1 Symbol: positive=0, negative=1 Overload (or under zero)=1 dynamic=1 unit: lb=0, kg=1 Constant 1 Constant 0 State C Bit2 Bit1 Bit0 unit 0 0 0 Kg or lb 0 0 1 g 0 1 0 t Bit 3 printing=1 Bit 4 Extend display=1 Bit 5 Bit 6 Constant 1 Constant 0Adobe PDF library 15.00 Adobe Illustrator CC 23.1 (Windows)