Dimension

L         *        W         *         H
179     *        99         *         30    mm
7.05    *       3.90       *        1.18  inch

MEAN WELL RSP-100 Series 100W Single Output with PFC Function

MEAN WELL - PFC MEAN WELL - ROHS            Conformity declaration Icon 1         MEAN WELL - C RU US     MEAN WELL - TUV

R33100    AS/NZS62368-1  UL62368-1   BS EN/EN62368-1
RoHS                                                         BS EN/EN61558-1
CNS14336-1                                          BS EN/EN61558-2-16

MEAN WELL - CCC           EAC Icon 3     Mean Well - CB    CE Icon 8     UKCA Icon
GB4943.1   TPTC004   IEC62368-1

MEAN WELL - Industrial 1  MEAN WELL - Automate 1  MEAN WELL - Telecom 1  MEAN WELL - Network 1  MEAN WELL - EV 1

Square Bullet 1 Features
  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 88%
  • Cooling by free air convection
  • Built-in remote ON-OFF control
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • LED indicator for power on
  • 3 years warranty
Square Bullet 1 Applications
  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application
Square Bullet 1 GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Square Bullet 1 Description

RSP-100 is a 100W single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C.

Square Bullet 1 Model Encoding / Order Information

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - a1

  1. Output voltage (3.3V/5V/7.5V/12V/13.5V/15V/24V/27V/48V)
  2. Output wattage
  3. Series name
SPECIFICATION
MODEL RSP-100-3.3 RSP-100-5 RSP-100-7.5
OUTPUT DC VOLTAGE 3.3V 5V 7.5V
RATED CURRENT 20A 20A 13.5A
CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.5A
RATED POWER 66W 100W 101.25W
RIPPLE & NOISE (max.)   Note.2 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V
VOLTAGE TOLERANCE   Note.3 ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 83% 86% 87%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT WORKING TEMP. -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/°C (0 ~ 50°C)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION 179*99*30mm (L*W*H)
PACKING 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Star Bullet icon 1 Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSP-100-12 RSP-100-13.5 RSP-100-15
OUTPUT DC VOLTAGE 12V 13.5V 15V
RATED CURRENT 8.5A 7.5A 6.7A
CURRENT RANGE 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A
RATED POWER 102W 101.25W 100.5W
RIPPLE & NOISE (max.)   Note.2 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V
VOLTAGE TOLERANCE   Note.3 ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 86% 86.5% 87%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT WORKING TEMP. -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/°C (0 ~ 50°C)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION 179*99*30mm (L*W*H)
PACKING 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Star Bullet icon 1 Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSP-100-24 RSP-100-27 RSP-100-48
OUTPUT DC VOLTAGE 24V 27V 48V
RATED CURRENT 4.2A 3.8A 2.1A
CURRENT RANGE 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A
RATED POWER 100.8W 102.6W 100.8W
RIPPLE & NOISE (max.)   Note.2 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
VOLTAGE TOLERANCE   Note.3 ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 87% 87% 88%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT WORKING TEMP. -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/°C (0 ~ 50°C)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION 179*99*30mm (L*W*H)
PACKING 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Star Bullet icon 1 Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Square Bullet 1 Mechanical Specification

Case No.227A   Unit: mm

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - a2

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - a3

  1. 4-M4(Both Sides) L=4mm

Terminal Pin No. Assignment

Pin No.

Assignment Pin No. Assignment
1 AC/L 4,5

DC OUTPUT -V

2

AC/N 6,7 DC OUTPUT +V
3 FG earth symbol

Remote ON/OFF(CN1): JST S2B-XH or equivalent(optional)

Pin No.

Assignment Mating Housing Terminal
1 RC+ JST XHP or equivalent

JST SXH-001T-P0.6 or equivalent

2

RC-

Square Bullet 1 Block Diagram

PFC fosc : 100KHz
PWM fosc : 100KHz

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - a4

  1. EMI FILTER & RECTIFIERS
  2. PFC CIRCUIT
  3. POWER SWITCHING
  4. RECTIFIERS & FILTER
  5. ACTIVE START CIRCUIT
  6. PWM & PFC CONTROL
  7. CONSTANT CURRENT & DETECTION CIRCUIT
  8. REMOTE CONTROL
Square Bullet 1 Derating Curve

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - b1

Square Bullet 1 Output Derating VS Input Voltage

MEAN WELL RSP-100 Series 100W Single Output with PFC Function - b2

File Name:RSP-100-SPEC   2024-02-23

Downloaded from Arrow.com.

Documents / Resources

MEAN WELL RSP-100 Series 100W Single Output with PFC Function [pdf] Owner's Manual
RSP-100-3.3, RSP-100-5, RSP-100-7.5, RSP-100-12, RSP-100-13.5, RSP-100-15, RSP-100-24, RSP-100-27, RSP-100-48, RSP-100 Series 100W Single Output with PFC Function, 100W Single Output with PFC Function, Single Output with PFC Function, Output with PFC Function, PFC Function, Function
MEAN WELL RSP-100 Series 100W Single Output with PFC Function [pdf] Owner's Manual
RSP-100 Series, RSP-100 Series 100W Single Output with PFC Function100W Single Output with PFC Function, Single Output with PFC Function, PFC Function, Function

References

Leave a comment

Your email address will not be published. Required fields are marked *