Product Specifications:

  • Model: PLC-100 series
  • Output:
    • DC Voltage: 12V, 15V, 20V, 24V, 27V, 36V,
      48V
    • Constant Current Region: 9 ~ 12V, 11.25 ~ 15V,
      15 ~ 20V, 18 ~ 24V
    • Rated Current: 5A, 4.8A, 4A
    • Current Range: 0 ~ 5A, 0 ~ 4.8A, 0 ~ 4A
    • Ripple & Noise (max.): 150mVp-p
    • Voltage Adj. Range(Vo ADJ): 10.2 ~ 12V, 12.8 ~
      15V, 17 ~ 20V, 20.4 ~ 24V
    • Current Adj. Range(Io ADJ): 3.75 ~ 5A, 3.6 ~
      4.8A, 3 ~ 4A
    • Line Regulation:
    • Load Regulation:
    • Setup, Rise Time: 500ms, 80ms/230VAC; 1200ms,
      80ms/115VAC at full load
    • Hold Up Time (Typ.): 60ms/230VAC; 16ms/115VAC
      at full load
  • Input:
    • Voltage Range: 90 ~ 264VAC; 127 ~ 370VDC
    • Frequency Range: 47 ~ 63Hz
    • Power Factor (Typ.): PF>0.95/115VAC,
      PF>0.95/230VAC at full load
    • Total Harmonic Distortion: THD < 20% when
      output loading75% at 115VAC/230VAC input
    • Efficiency (Typ.): 83%, 87%, 88.5%, 88%, and
      more
    • AC Current (Typ.), Inrush Current (Typ.):
    • Max. No. of PSUs on 16A Circuit Breaker: 3
      units (circuit breaker of type B) / 5 units (circuit breaker of
      type C) at 230VAC
    • Leakage Current:

Product Usage Instructions:

Installation:

  1. Ensure the input voltage range matches the power supply
    specifications.
  2. Connect the output terminals to the device requiring
    power.
  3. Securely mount the power supply in a well-ventilated area.

Adjusting Voltage and Current:

To adjust the output voltage or current, use the provided
adjustment ranges according to your requirements. Always refer to
the user manual for specific guidance.

Safety Precautions:

  • Do not operate the power supply in wet environments.
  • Avoid overloading the power supply beyond the rated
    specifications.

Frequently Asked Questions (FAQ):

Q: What is the maximum number of units that can be connected on
a single circuit breaker?

A: The maximum number of power supply units that can be
connected on a single circuit breaker is detailed in the
specifications as per the type of circuit breaker and input
voltage.

Q: How do I adjust the voltage and current output?

A: You can adjust the voltage and current output using the
provided adjustment ranges mentioned in the product specifications.
Refer to the user manual for detailed instructions on adjusting
these parameters.

“`

100W Single Output Switching Power Supply

PLC-100 series

SPECIFICATION

LPS

..

MODEL

PLC-100-12 PLC-100-15 PLC-100-20 PLC-100-24 PLC-100-27 PLC-100-36

User’s Manual
PLC-100-48

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

CONSTANT CURRENT REGION Note.4 9 ~ 12V

11.25 ~ 15V

15 ~ 20V

18 ~ 24V

RATED CURRENT

Note.6 5A

5A

4.8A

4A

CURRENT RANGE Note.6 0 ~ 5A

0 ~ 5A

0 ~ 4.8A

0 ~ 4A

RATED POWER

Note.6 60W

75W

96W

96W

RIPPLE & NOISE (max.) Note.2 150mVp-p

150mVp-p

150mVp-p

150mVp-p

VOLTAGE ADJ. RANGE(Vo ADJ) 10.2 ~ 12V

12.8 ~ 15V

17 ~ 20V

20.4 ~ 24V

CURRENT ADJ. RANGE(Io ADJ) 3.75 ~ 5A

3.75 ~ 5A

3.6 ~ 4.8A

3 ~ 4A

VOLTAGE TOLERANCE Note.3 ±3.0%

±3.0%

±3.0%

±3.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME

500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load

HOLD UP TIME (Typ.)

60ms/230VAC 16ms/115VAC at full load

27V 20.25 ~ 27V 3.55A 0 ~ 3.55A 95.85W 150mVp-p 23 ~ 27V 2.6 ~ 3.55A ±3.0%

36V 27 ~ 36V 2.65A 0 ~ 2.65A 95.4W 150mVp-p 30.6 ~ 36V 2 ~ 2.65A ±2.0%

48V 36 ~ 48V 2A 0 ~ 2A 96W 200mVp-p 40.8 ~ 48V 1.5 ~ 2A ±2.0%

INPUT

VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to “Power Factor Characteristic” curve)

TOTAL HARMONIC DISTORTION THD< 20% when output loading75% at 115VAC/230VAC input

EFFICIENCY (Typ.)

83%

87%

88.5%

88.5%

88%

88%

AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC COLD START 40A(twidth=950s measured at 50% Ipeak) at 230VAC

20V ~ 48V:1.1A/115VAC

88.5% 0.55A/230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

OVER CURRENT (Typ.) Note.4 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

13 ~ 16V

16.5 ~ 20V

22 ~ 27V

27 ~ 34V

30 ~ 36V

Protection type : Shut down and latch off o/p voltage, re-power on to recover

39 ~ 48V

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover

WORKING TEMP. WORKING HUMIDITY

-30 ~ +50 (Refer to “Derating Curve”) 20 ~ 95% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

52 ~ 64V

SAFETY STANDARDS

UL1310, TUV BS EN/EN60950-1, BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14, GB19510.1, Note.7 CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved

SAFETY & EMC

WITHSTAND VOLTAGE ISOLATION RESISTANCE
EMC EMISSION

I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55015, GB/T 17743, GB17625.1, BS EN/EN61000-3-2,-3, Class C (70% load) ; BS EN/EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55035, light industry level, (surge 4KV), EAC TP TC 020

MTBF

2688.3K hrs min. Telcordia SR-332 (Bellcore) ; 297.9Khrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

200.5*69.5*35mm (L*W*H)

PACKING

0.52Kg; 25pcs/14Kg/0.65CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Please refer to “DRIVING METHODS OF LED MODULE”.

5. Derating may be needed under low input voltage. Please check the static characteristics for more details.

6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.

7. Safety and EMC design refer to BS EN/EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.

8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the

complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. 10. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

11. PLC-100-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be

use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).

Downloaded from Arrow.comPro. duct Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:PLC-100-SPEC 2024-09-25

100W Single Output Switching Power Supply
Mechanical Specification
200.5

PLC-100 series
Case No.981A Unit:mm Tolerance:±1
6.26

20.2

69.5

T case

100.25

34.75

2-R2.5

1

2-R9.0

1

20.2

2

2

3

6.26

T case: Max. Case Temperature.

35

Block Diagram

Terminal Pin No. Assignment (TB1) : SWITCHLAB MB310-75003

Pin No. Assignment

1

FG

2

AC/N

3

AC/L

Terminal Pin No. Assignment (TB2) : SWITCHLAB MB310-75002

Pin No. Assignment

1

+V

2

-V

Fosc : 100KHz

EMI FILTER

I/P

&

RECTIFIERS

PFC CIRCUIT

POWER SWITCHING

RECTIFIERS &
FILTER

+V -V

O.L.P.

FG

O.L.P.

PWM & PFC

PFC

CONTROL

CONTROL

DETECTION CIRCUIT

O.V.P.

Derating Curve

Static Characteristics

LOAD (%) LOAD (%)

100 80 60 40 20

-30

0

10

20

30

40

50

60 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz

File Name:PLC-100-SPEC 2024-09-25

Downloaded from Arrow.com.

PF EFFICIENCY (%)

100W Single Output Switching Power Supply

PLC-100 series

Power Factor Characteristic

1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0.84 0.82 0.80 0.78
50%

Constant Current Mode

60%

70%

80%

90%

LOAD

115V 230V
100% (100W)

EFFICIENCY vs LOAD (48V Model)

PLC-100 series possess superior working efficiency that up to 88.5% can be reached in field applications.

92

90

88

86

84

82

80 115V
78

76

230V

74

72

70

68

66 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

DRIVING METHODS OF LED MODULE

There are two major kinds of LED drive method “direct drive” and “with LED driver”. A typical LED power supply may either work in “constant voltage mode (CV) or constant current mode (CC)” to drive the LEDs. Mean Well’s LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].

Vo(%)

100
75 (min.)

(A) Constant Voltage area

(B) Constant
Current area

In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL.

(C) Hiccup Protection

50

100

Io (%)

Typical LED power supply I-V curve

File Name:PLC-100-SPEC 2024-09-25

Downloaded from Arrow.com.

Documents / Resources

MEAN-WELL PLC-100-12 Series Single Output Switching Power Supply [pdf] Owner's Manual
PLC-100-12, PLC-100-15, PLC-100-20, PLC-100-24, PLC-100-27, PLC-100-36, PLC-100-48, PLC-100-12 Series Single Output Switching Power Supply, PLC-100-12 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *