MEAN WELL Logo100W Single Output Switching Power SupplyMEAN WELL PLC 100-12 Series Single Output Switching Power SupplyPLC-100 series
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Features:

  • Universal AC input / Full range
  • High efficiency up to 88.5%
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in active PFC function
  • Class 2 power unit
  • Pass LPS
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

SPECIFICATION

MODEL PLC-100-12 PLC-100-15 PLC-100-20 PLC-100-24 PLC-100-27 PLC-100-36 PLC-100-48
OUTPUT DC VOLTAGE 12V 15V 20V 24V 27V 36V 48V
CONSTANT CURRENT REGION Note.4 9 ~ 12V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 20.25 ~ 27V 27 ~ 36V 36 ~ 48V
RATED CURRENT Note.6 5A 5A 4.8A 4A 3.55A 2.65A 2A
CURRENT RANGE Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A
RATED POWER Note.6 60W 75W 96W 96W 95.85W 95.4W 96W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ.RANGE(VoADJ) 10.2 ~ 12V 12.8 ~ 15V 17 ~ 20V 20.4 ~ 24V 23 ~ 27V 30.6 ~ 36V 40.8 ~ 48V
CURRENT ADJ. RANGE(IoADJ) 3.75 ~ 5A 3.75 ~ 5A 3.6 ~ 4.8A 3 ~ 4A 2.6 ~ 3.55A 2 ~ 2.65A 1.5 ~ 2A
VOLTAGE TOLERANCE Note.3 ±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME 500ms, 80ms/230VAC  1200ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC 16ms/115VAC at full load
INPUT VOLTAGE RANGE Note.5 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading¾75% at 115VAC/230VAC input
EFFICIENCY (Typ.) 83% 87% 88.5% 88.5% 88% 88% 88.5%
AC CURRENT (Typ.) 12V:0.8A/115VAC  0.4A/230VAC  15V:0.9A/115VAC  0.45A/230VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A(twidth=950μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER CURRENT (Typ.) Note.4 95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS Note.7 UL1310, TUV BS EN/EN60950-1, BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14, GB19510.1, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55015, GB/T 17743, GB17625.1, BS EN/EN61000-3-2,-3, Class C (¾70% load) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55035, light industry level, (surge 4KV), EAC TP TC 020
OTHERS MTBF 2688.3K hrs min.     Telcordia SR-332 (Bellcore) ;  297.9Khrs min.      MIL-HDBK-217F (25℃)
DIMENSION 200.5*69.5*35mm (L*W*H)
PACKING 0.52Kg; 25pcs/14Kg/0.65CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to “DRIVING METHODS OF LED MODULE”.
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.
7. Safety and EMC design refer to BS EN/EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
11. PLC-100-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply -Mechanical

Power Factor Characteristic

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply - Characteristic

EFFICIENCY vs LOAD (48V Model)
PLC-100 series possess superior working efficiency that up to 88.5% can be reached in field applications.

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply - Characteristic 1

DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method “direct drive” and “with LED driver”.
A typical LED power supply may either work in “constant voltage mode (CV) or constant current mode (CC)” to drive the LEDs.
Mean Well’s LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply - Characteristic 2In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply -Qr Codehttp://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf

MEAN WELL PLC 100-12 Series Single Output Switching Power Supply - IconDownloaded from Arrow.com.