PLC-100-12 Series Single Output Switching Power Supply
“
Product Specifications:
- Model: PLC-100 series
- Output:
- DC Voltage: 12V, 15V, 20V, 24V, 27V, 36V,
48V - Constant Current Region: 9 ~ 12V, 11.25 ~ 15V,
15 ~ 20V, 18 ~ 24V - Rated Current: 5A, 4.8A, 4A
- Current Range: 0 ~ 5A, 0 ~ 4.8A, 0 ~ 4A
- Ripple & Noise (max.): 150mVp-p
- Voltage Adj. Range(Vo ADJ): 10.2 ~ 12V, 12.8 ~
15V, 17 ~ 20V, 20.4 ~ 24V - Current Adj. Range(Io ADJ): 3.75 ~ 5A, 3.6 ~
4.8A, 3 ~ 4A - Line Regulation:
- Load Regulation:
- Setup, Rise Time: 500ms, 80ms/230VAC; 1200ms,
80ms/115VAC at full load - Hold Up Time (Typ.): 60ms/230VAC; 16ms/115VAC
at full load - Input:
- Voltage Range: 90 ~ 264VAC; 127 ~ 370VDC
- Frequency Range: 47 ~ 63Hz
- Power Factor (Typ.): PF>0.95/115VAC,
PF>0.95/230VAC at full load - Total Harmonic Distortion: THD < 20% when
output loading75% at 115VAC/230VAC input - Efficiency (Typ.): 83%, 87%, 88.5%, 88%, and
more - AC Current (Typ.), Inrush Current (Typ.):
- Max. No. of PSUs on 16A Circuit Breaker: 3
units (circuit breaker of type B) / 5 units (circuit breaker of
type C) at 230VAC - Leakage Current:
Product Usage Instructions:
Installation:
- Ensure the input voltage range matches the power supply
specifications. - Connect the output terminals to the device requiring
power. - Securely mount the power supply in a well-ventilated area.
Adjusting Voltage and Current:
To adjust the output voltage or current, use the provided
adjustment ranges according to your requirements. Always refer to
the user manual for specific guidance.
Safety Precautions:
- Do not operate the power supply in wet environments.
- Avoid overloading the power supply beyond the rated
specifications.
Frequently Asked Questions (FAQ):
Q: What is the maximum number of units that can be connected on
a single circuit breaker?
A: The maximum number of power supply units that can be
connected on a single circuit breaker is detailed in the
specifications as per the type of circuit breaker and input
voltage.
Q: How do I adjust the voltage and current output?
A: You can adjust the voltage and current output using the
provided adjustment ranges mentioned in the product specifications.
Refer to the user manual for detailed instructions on adjusting
these parameters.
“`
100W Single Output Switching Power Supply
PLC-100 series
SPECIFICATION
LPS
..
MODEL
PLC-100-12 PLC-100-15 PLC-100-20 PLC-100-24 PLC-100-27 PLC-100-36
User’s Manual
PLC-100-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.4 9 ~ 12V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
RATED CURRENT
Note.6 5A
5A
4.8A
4A
CURRENT RANGE Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
RATED POWER
Note.6 60W
75W
96W
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE(Vo ADJ) 10.2 ~ 12V
12.8 ~ 15V
17 ~ 20V
20.4 ~ 24V
CURRENT ADJ. RANGE(Io ADJ) 3.75 ~ 5A
3.75 ~ 5A
3.6 ~ 4.8A
3 ~ 4A
VOLTAGE TOLERANCE Note.3 ±3.0%
±3.0%
±3.0%
±3.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±2.0%
SETUP, RISE TIME
500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC 16ms/115VAC at full load
27V 20.25 ~ 27V 3.55A 0 ~ 3.55A 95.85W 150mVp-p 23 ~ 27V 2.6 ~ 3.55A ±3.0%
36V 27 ~ 36V 2.65A 0 ~ 2.65A 95.4W 150mVp-p 30.6 ~ 36V 2 ~ 2.65A ±2.0%
48V 36 ~ 48V 2A 0 ~ 2A 96W 200mVp-p 40.8 ~ 48V 1.5 ~ 2A ±2.0%
INPUT
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading75% at 115VAC/230VAC input
EFFICIENCY (Typ.)
83%
87%
88.5%
88.5%
88%
88%
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC COLD START 40A(twidth=950s measured at 50% Ipeak) at 230VAC
20V ~ 48V:1.1A/115VAC
88.5% 0.55A/230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT (Typ.) Note.4 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
39 ~ 48V
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
WORKING TEMP. WORKING HUMIDITY
-30 ~ +50 (Refer to “Derating Curve”) 20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
52 ~ 64V
SAFETY STANDARDS
UL1310, TUV BS EN/EN60950-1, BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14, GB19510.1, Note.7 CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
SAFETY & EMC
WITHSTAND VOLTAGE ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55015, GB/T 17743, GB17625.1, BS EN/EN61000-3-2,-3, Class C (70% load) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55035, light industry level, (surge 4KV), EAC TP TC 020
MTBF
2688.3K hrs min. Telcordia SR-332 (Bellcore) ; 297.9Khrs min. MIL-HDBK-217F (25)
OTHERS DIMENSION
200.5*69.5*35mm (L*W*H)
PACKING
0.52Kg; 25pcs/14Kg/0.65CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to “DRIVING METHODS OF LED MODULE”.
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.
7. Safety and EMC design refer to BS EN/EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. 10. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
11. PLC-100-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be
use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).
Downloaded from Arrow.comPro. duct Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:PLC-100-SPEC 2024-09-25
100W Single Output Switching Power Supply
Mechanical Specification
200.5
PLC-100 series
Case No.981A Unit:mm Tolerance:±1
6.26
20.2
69.5
T case
100.25
34.75
2-R2.5
1
2-R9.0
1
20.2
2
2
3
6.26
T case: Max. Case Temperature.
35
Block Diagram
Terminal Pin No. Assignment (TB1) : SWITCHLAB MB310-75003
Pin No. Assignment
1
FG
2
AC/N
3
AC/L
Terminal Pin No. Assignment (TB2) : SWITCHLAB MB310-75002
Pin No. Assignment
1
+V
2
-V
Fosc : 100KHz
EMI FILTER
I/P
&
RECTIFIERS
PFC CIRCUIT
POWER SWITCHING
RECTIFIERS &
FILTER
+V -V
O.L.P.
FG
O.L.P.
PWM & PFC
PFC
CONTROL
CONTROL
DETECTION CIRCUIT
O.V.P.
Derating Curve
Static Characteristics
LOAD (%) LOAD (%)
100 80 60 40 20
-30
0
10
20
30
40
50
60 (HORIZONTAL)
AMBIENT TEMPERATURE ()
100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz
File Name:PLC-100-SPEC 2024-09-25
Downloaded from Arrow.com.
PF EFFICIENCY (%)
100W Single Output Switching Power Supply
PLC-100 series
Power Factor Characteristic
1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0.84 0.82 0.80 0.78
50%
Constant Current Mode
60%
70%
80%
90%
LOAD
115V 230V
100% (100W)
EFFICIENCY vs LOAD (48V Model)
PLC-100 series possess superior working efficiency that up to 88.5% can be reached in field applications.
92
90
88
86
84
82
80 115V
78
76
230V
74
72
70
68
66 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method “direct drive” and “with LED driver”. A typical LED power supply may either work in “constant voltage mode (CV) or constant current mode (CC)” to drive the LEDs. Mean Well’s LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
Vo(%)
100
75 (min.)
(A) Constant Voltage area
(B) Constant
Current area
In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL.
(C) Hiccup Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:PLC-100-SPEC 2024-09-25
Downloaded from Arrow.com.
Documents / Resources
![]() |
MEAN-WELL PLC-100-12 Series Single Output Switching Power Supply [pdf] Owner's Manual PLC-100-12, PLC-100-15, PLC-100-20, PLC-100-24, PLC-100-27, PLC-100-36, PLC-100-48, PLC-100-12 Series Single Output Switching Power Supply, PLC-100-12 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |