Features
- Support 1 + 1 and N+ 1 redundancy system
- 2 channels input and 1 output
- Suitable for red undance operation of 12V/24V/48V system
- Output current up to 20A
- Cooling by free air convection
- -40~+80°C ultra-wide operating temperature ( >+60°C derating)
- 32mm slim width
- Built-in 2 channels DC OK signal and alarm relay contact
- Installed on DIN Rail TS35/7.5 or 15
- 3 years warranty
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
The DRDN20 series is a 20A redundancy module that can be used with a power supply to improve overall system operation reliability. Product key features include:12V/24V/48V input voltage for selection, support N+1 and 1 +1 redundancy systems, built-in two rails DC input contacts and single output. The MOSFET technology implemented can reduce heat loss and reduce the voltage difference between the input and output voltages, built-in 2 channels DC OK relay contacts for monitoring output status, ultra-wide operating temperature of -40 to +80°C and narrow width (32mm).
Model Encoding
SPECIFICATION
MODEL | ORON20-▯ | |||||||||
▯ =12V, 24V. 48V | ||||||||||
INPUT | NUMBER OF INPUT | 2 Channels | ||||||||
DC NORMAL VOLTAGE | 12Vdc | 24Vdc | 48Vdc | |||||||
DC VOLTAGE RANGE | 9-14Vdc | 19- 29Vdc | 36-60Vdc | |||||||
RATED CURRENT | 0-20A per input Continuous | |||||||||
VOLTAGE DROP (Vin-Vou)t (max.) | 0.25V | |||||||||
PEAK CURRENT | 0-30A per input SSec. | |||||||||
EFFICIENCY (Typ.) | 98% | |||||||||
INPUT REVERSE CURRENT (max.) | 1mA | |||||||||
INPUT REVERSE VOLTAGE (max.) | 40Vdc 40Vdc | 40Vdc | 65Vdc | |||||||
OUTPUT | RATED CURRENT | 0-20A, Continuous | ||||||||
PEAK CURRENT (max.) | 30A, 5Sec. | |||||||||
CAPACITANCE (Typ.) | 320 uF | |||||||||
STANDBY POWER LOSSES(Typ.) | 1.5W | |||||||||
PROTECTION | OVERLOAD | < 30A,5Sec. No damage | ||||||||
SHORT CIRCUIT | < 30A,5Sec. No damage | |||||||||
FUNCTION | REDUNDANCY | For 1+1 redundancy, and support N+1 redundancy | ||||||||
BOTH INPUTS VOLTAGE ALARM | <8.SVor >14.7V(± 5%) | <18V or >31V (± 5%) | <34.2Vor >63V ( ± 5%1 | |||||||
RELAY | 30Vdc/1A resistive load | |||||||||
LEO STATUS DISPLAY | Green LED OK | |||||||||
ENVIRONMENT | COOLING | Free air connection | ||||||||
WORKING TEMP. | Note.2 | -40 – +ado’s (Referto’ Derating Curve”) | ||||||||
WORKING HUMIDITY | 5- 95%RH non-condensing | |||||||||
STORAGE TEMP. | -40 – +85’C | |||||||||
TEMP. COEFFICIENT | ± 0 03%/’C 10 – 60′ Cl | |||||||||
VIBRATION | Component:10- 500Hz, 5G 10 min./cycle 6,0min. | echelon, Y, Zaxes; Mounting: Compliance to IEC 61373 | ||||||||
OPERATING ALTITUDE | Note.3 | 5000 meters/OVC11 | ||||||||
SAFETY & EMC (Note. 4) | SAFETY STANDARDS | IEC 6236-81, UL 62368-,1EAC TP TC 004 approved | ||||||||
WITHSTAND VOLTAGE | IP/OP· Chassis: 0.5KVac; IP/OP-Relay: 0.5KVac ; Relay· Chassis: O.SKVac | |||||||||
ISOLATION RESISTANCE | IP/OP· Chassis, IP/OP-Relay, Relay· Chassis:>10M0Ohms/ 500Vdc/ 25″C/ 70% RH | |||||||||
EMC EMISSION | Parameter | Standard | Test Level Note | |||||||
Conducted | BS EN/EN55032(CISPR 32 | Class B | ||||||||
Radiated | BS EN/EN55032t(SCPR32 | Class B | ||||||||
Voltage Flicker | —– | —– | ||||||||
Harmonic Current | -·· | —– | ||||||||
EMC IMMUNITY | BS EN/EN 55035, BS EN/EN 61000-6-2(BS EN/EN 50082-2) | |||||||||
Parameter | Standard | Test Level Note | ||||||||
ESD | BS EN/EN6100-4-2 | Level 4,15KV air; Level 3, 8KV contact; criteria A | ||||||||
Radiated | BS EN/EN 6100-4-3 | Level3, 10V/m; criteria A | ||||||||
EFT/ Burst | BS EN/EN 6100-4-4 | Level3, 2KV; criteria A | ||||||||
Surge | BS EN/EN6100-4-5 | Level 3 1KV/line line; level 3 2KV/line- Line Chassis; criteria A |
||||||||
Conducted | BS EN/EN 6100-4-6 | Level 3, 10V; criteria A | ||||||||
Magnetic Field | BS EN/EN6100-4-8 | Level 4, 30A/m; criteria A | ||||||||
OTHERS | MTBF | 1836.0Khrsmin. Telcordia SR-332 (Bellcore) ; 482.1K hrsmin. MIL-HDBK-217F(25’C) | ||||||||
DIMENSION | 32’125.21′ 02mm(W’H’ D) | |||||||||
PACKING | 0.35Kg;28ps/1c0.8Kg/1.24 CUT | |||||||||
NOTE |
|
Block Diagram
DC OK Rela Contact
Contact Ratinos (max.) | 30V/1Aresistive load |
Contact Close (DCOK) | PSU turns on |
Contact Open (DC Fail) | PSU turns off/ over or under input voltage |
Derating Curve
Output Derating VS Input Voltage
Typical Application Notes
- 1+1 Redundancy:
Using 1 more PSU as the redundant unit
- 1+N Redundancy:
Using more PS Us as the redundant units to increase the reliability
- Single Use:
Connecting only one PSU to one DRDN20 to reduce the stress of the MOSFET and hence increase the reliability
Mechanical Specification
Terminal Pin No. Assignment (TB 1,TB2)
CaseNo. 221 D Unit: mm
Pin No. | Assignment |
1,2 | Alarm1 DC OK |
3,4 | Alarm2 DC OK |
5 | FG |
6,7 | DC output +Vout |
8 | DC output •Vout |
Terminal Pin No. Assignment (TB3)
PinNo. | Assignment |
1 | DC input +Vint |
2 | DC input -Vinl |
3 | DC input +Vln2 |
4 | DC input -Vin2 |
Installation Instruction
This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual.