EPEVER MT11 Remote Meter User Manual
EPEVER MT11 Remote Meter

Important Safety Instructions

Thank you for selecting the remote meter.

General safety information

  • Please contact our company or transportation if the product has been damaged.
  • Please read this manual carefully before using the product and pay attention to the safety information.
  • Keep the product away from rain, exposure, severe dust, vibrations, corrosive gas, and intense electromagnetic interference.
  • Do not allow water to enter the product.
  • There are no serviceable parts inside the product. Do not disassemble or attempt to repair it.

Recommendations

  • The MT11 is only allowed to connect with the DR-N series charge controller. Please confirm before purchase and installation.
  • Please do not install MT11 in a situation with strong electromagnetic interference.

Overview

The MT11 remote meter, matching with the DuoRacer series controllers, can monitor the controller’s running data and working status.

Features:

  • Easy to install and operate
  • Real-time display of fault alarms
  • Locally readable of real-time parameters
  • Powered by the controller directly

Product Classification

  1. MT11(include the 1.5m communication cable)
    • Remote meter MT11
    • 1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150)
    • Base of MT11
  2. MT11 (include the 5m communication cable)
    • Remote meter MT11
    • 5m communication cable (Model: CC-RS485-RS485-3.81-4P-500)
    • Base of MT11
  3. MT11 (include the 10m communication cable)
    • Remote meter MT11
    • 10m communication cable (Model: CC-RS485-RS485-3.81-4P-1000)
    • Base of MT11
  4. MT11(Do not include the communication cable)
    • Remote meter MT11
    • 1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150)
    • Do not include Base of MT11

NOTE: The customers can purchase the product according to the requirement.

Installation

Base of MT11 (Optional accessory) 
Installation

Mechanical parameter Parameter
Dimension 114mm x 114mm x 44.41mm
Mounting size 88.6mm x 88.6mm
Mounting hole size Φ5mm

Wall Installation

Wall Installation
Wall Installation

Step1: Locate and drill screw holes based on the Frame Mounting dimension of the base, and erect the plastic expansion bolts.

Step2: Use four PA4.2×32 self-tapping screws to fix the Frame.

Step3: Remove the decorative shell.

Step4: Use four M4×8 pan head screws to mount the MT11 surface on the Frame.

Step5: Install the decorative shell.

Surface Installation

Surface Installation

Step1: Locate and drill screw holes based on the installation size of the surface.

Step2: Remove the decorative shell.

Step3: Use four M4×8 cross recessed pan head screws with M4 nuts to mount the MT11 surface onto the panel.

Step4: Install the decorative shell.

NOTE: Take full consideration of the plugging/unplugging space of the communication cable and the cable length during installation.

Product Features

Front View

Front View

  • LCD screen
    Man-machine interaction operation interface. Refer to chapter 6, Display and operation.
  • Buttons
    The meter buttons include two function buttons and one switch button.
Icon Press the button
  1. PV array parameters
  2. Storage battery parameters
  3. Browse    the    start       battery parameters automatically (Auto)
Icon Press the button Browse the PV array parameters Browse the Storage battery parameters
Browse the start battery parameters
Press the button and hold on 5s Temperature unitsBattery type
Icon Press the button The meter is powered ON
Press the button and hold on 5s The meter is powered OFF

Rear View

Rear View

  • RS485communicationport
    It is used to connect the controller to supply power to the MT11.
  • Communication cable’s models
    CC-RS485-RS485-3.81-4P-150(Included)
    CC-RS485-RS485-3.81-4P-1000(Optional)
    CC-RS485-RS485-3.81-4P-2000(Optional)
  • Pins definition
    Pins
     
    PIN Definition
    1 DC5V
    2 RS-485-B
    3 RS-485-A
    4 GND

Display and operation

LCD

LCD

Icon Instruction Icon Instruction
Display symbol BATT1 battery capacity level0~12% Display symbol BATT2battery capacity level0~12%
Display symbol BATT1battery capacity level13%~35% Display symbol BATT2battery capacity level13%~35%
Display symbol BATT1battery capacity level36%~61% Display symbol BATT2battery capacity level36%~61%
Display symbol BATT1battery capacity level62%~86% Display symbol BATT2battery capacity level62%~86%
Display symbol BATT1battery capacity level87%~100% Display symbol BATT2battery capacity level87%~100%
Display symbol Day Display symbol PV array
Display symbol Night Display symbol BATT1 charging icon
Display symbol Display the parameters of PV Display symbol BATT2charging icon
Display symbol Display the parameters of BATT1 Display symbol BATT1temperature parameters
Display symbol Display the parameters of BATT2 AES AES signal icon
Display symbol Setting icon Batt. Type Battery type icon
Display symbol Auto global view sign Min Minimum voltage icon
Display symbol Fault Icon Max. Maximum voltage icon
  • (①) Battery power capacity is calculated by the linear relationship between the disconnect voltage of low voltage and float charging voltage.

Auto Global-View Mode

Operation:
Step1: Press the Icon button, Auto is appear.
Step2: Press the Icon button and select the Display symbol.
Auto Global-View Mode

Echo Loop: PV voltage ——PV current ——PV power——Battery power——BATT1 voltage——BATT1 current——Max. BATT1 voltage——Min.BATT1 voltage——BATT1 temperature——BATT1 battery type——BATT2 voltage——BATT2 current——Max. BATT1 voltage——Min.BATT2 voltage——PV voltage

Temperature Units

Temperature Units

Operation:
Step1: Press the Icon button under the battery temperature interface.
Step2: Press the Icon button to select the temperature unit.
Step3: Press the Icon button to set successfully

Clear the Generated Energy

Display

Press the Icon and Icon button and hold on 5s to clear the generated energy.

Battery Type

Display

Operation:

Step1: Press the Icon button and hold 5s under the battery type interface.
Step2: Press the Icon button when the battery type interface is flashing.
Step3: Press the Icon button to confirm the battery type.

Battery type

SEL 1 BATT112V Sealed SEL 2 BATT124V Sealed
GEL 1 BATT112V Gel GEL 2 BATT124V Gel
FLD 1 BATT112V Flooded FLD2 BATT124V Flooded
LI F4 LiFePO4(4S) L1 F8 LiFePO4(8S)
L1 C3 Li-NiCoMn (3S) L1 C6 Li-NiCoMn (6S)
USE User

Warning icon CAUTION: The battery voltage is set as default and not changeable when selecting the default battery type. Please change to “User” battery type before adjusting the battery voltage.

Warning icon CAUTION: Set the voltage of the “User” battery type via PC software only.

Lead-acid Battery Control Voltage Parameters
The parameters are in the 12V system at 25 ºC. Please double the values in the 24V system.

Battery type Sealed Gel Flooded User
Voltage parameter
Over Voltage Disconnect Voltage 16.0V 16.0V 16.0V 9~17V
Charging Limit Voltage 15.0V 15.0V 15.0V 9~17V
Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V 9~17V
Equalize Charging Voltage 14.6V —— 14.8V 9~17V
Boost Charging Voltage 14.4V 14.2V 14.6V 9~17V
Float Charging Voltage 13.8V 13.8V 13.8V 9~17V
Boost Voltage Reconnect Voltage 13.2V 13.2V 13.2V 9~17V
Low Voltage Reconnect Voltage 12.6V 12.6V 12.6V 9~17V
Under Voltage Reconnect Voltage 12.2V 12.2V 12.2V 9~17V
Under Voltage Warning Voltage 12.0V 12.0V 12.0V 9~17V
Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V 9~17V
Discharge Voltage Limit Voltage 10.6V 10.6V 10.6V 9~17V
Equalize Duration (minute) 120 —— 120 0~180
Boost Duration (minute) 120 120 120 10~180

NOTE:

  • When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration is 0 to180 minutes, and boost duration is 10 to180 minutes.
  • The following rules must be observed when modifying the value of the parameter in user battery type(factory default value is the same as sealed type):
  1. Over Voltage Disconnect Voltage > Charge Voltage Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Voltage Reconnect Voltage
  2. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
  3. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharge Voltage Limit Voltage
  4. Under Voltage Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharge Voltage Limit Voltage
  5. Boost Voltage Reconnect Voltage > Low Voltage Disconnect Voltage

Lithium Battery Control Voltage Parameters
The parameters are in the 12V system at 25 ºC; please double the values in the 24V system.

Battery type LiFePO4 (4S) Li-NiCoMn (3S) User
Voltage parameter
Over Voltage Disconnect Voltage 15.6V 13.5V 9~17V
Charge Voltage Limit Voltage 14.6V 12.6V 9~17V
Over Voltage Reconnect Voltage 14.5V 12.5V 9~17V
Equalize Charging Voltage 14.5V 12.5V 9~17V
Boost Charging Voltage 14.5V 12.5V 9~17V
Float Charging Voltage 13.8V 12.2V 9~17V
Boost Voltage Reconnect Voltage 13.2V 12.1V 9~17V
Low Voltage Reconnect Voltage 12.4V 10.5V 9~17V
Under Voltage Reconnect Voltage 12.5V 11.0V 9~17V
Under Voltage Warning Voltage 12.0V 10.5V 9~17V
Low Voltage Disconnect Voltage 11.0V 9.3V 9~17V
Discharge Voltage Limit Voltage 10.8V 9.3V 9~17V

The following rules must be observed when modifying the parameter values in User for the lithium battery.

  1. Over Voltage Disconnect Voltage > Over Charge Protection Voltage (Protection Circuit Modules(BMS))+0.2V
  2. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage = Charge Voltage Limit Voltage ≥ Equalize Charging Voltage = Boost Charging Voltage ≥ Float Charging Voltage > Boost Voltage Reconnect Voltage
  3. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharge Voltage Limit Voltage
  4. Under Voltage Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharge Voltage Limit Voltage
  5. Boost Voltage Reconnect Voltage > Low Voltage Reconnect Voltage
  6. Low Voltage Disconnect Voltage ≥ Over Discharge Protection Voltage (BMS)+0.2V)

Warning icon WARNING: The lithium battery voltage parameters must be set according to the voltage parameters of the lithium battery BMS.

Warning icon WARNING: The required accuracy of BMS shall be at least 0.2V. If the deviation is higher than 0.2V, the manufacturer will assume no liability for any system malfunction caused by this.

Fault Indication

Fault LCD Instruction
BATT2 overvoltage Display symbol Battery level shows full, battery frame blink, fault icon blink.
BATT2 over-discharged Display symbol Battery level shows empty, battery frame blink, fault icon blink.
BATT2 over temperature Display symbol Battery level shows current capacity, battery frame blink, fault icon blink, the temperature icon blink, the temperature value blink, the temperature unit blink.
BATT2 system voltage error① Display symbol Battery level shows empty, battery frame blink.
  • () No alarm for limited voltage fault when using Lithium batteries.

Specifications

Model MT11
Apply to model DRN series
Self-consumption(Power on) 13mA/5Vdc
Self-consumption(Power off) 4mA
Communication way RS485
Communication port 3.81-4P
RS485 cable CC-RS485-RS485-3.81-4P-150(1.5m)
CC-RS485-RS485-3.81-4P-500(5m)
CC-RS485-RS485-3.81-4P-1000(10m)
Environment temperature -20℃~+70℃
Storage temperature range -20℃~+70℃
Enclosure IP20
Dimension 98.4×98.4mm
Base cover dimension 114×114mm
Weight 0.11kg

Warranty

Before maintenance, check the product by the user manual or the after-sales personnel to determine the problem. If it is necessary to return to the factory for maintenance, please express the product to our company, prepay the freight and provide the ticket related to the purchase.

The returned product must be marked with the model, working environment, and fault description for the quick repair guarantee. This information is important to resolve the problems quickly.

We are not responsible for damage to the product caused by improper usage or failure to follow this user manual!

The maintenance is carried out regarding the above process and will incur a certain maintenance cost.

HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Beijing Tel: +86-10-82894896/82894112
Huizhou Tel: +86-752-3889706
E-mail: info@epever.com
Website: www.epever.com

Documents / Resources

EPEVER MT11 Remote Meter [pdf] User Manual
MT11, Remote Meter, MT11 Remote Meter, Meter
EPEVER MT11 Remote Meter [pdf] User Manual
MT11 Remote Meter, MT11, Remote Meter, Meter

References

Leave a comment

Your email address will not be published. Required fields are marked *