elpro-LOGO

ELPRO 1THR Humidity Temperature Probe

ELPRO-1THR -Humidity -Temperature -Probe-PRODUCT

Product Information

Specifications

  • Product Name: ECOLOG-PRO Radio Modules ECOLOG-PRO 2PTR, ECOLOG-PRO 1THR
  • Measurement Module: ECOLOG-PRO 2PTR
  • Functional Characteristics: Measurement module with two external temperature sensors
  • Power Supply: 3 AA Alkaline batteries
  • Battery Life: Up to 14 months (depending on radio connection stability and temperature range)
  • Case Material: ABS plastic
  • Dimensions: 137 mm x 70 mm x 57 mm
  • Measurement Range: User-defined
  • Measurement Resolution: User-programmable
  • Logging and Communication Interval: 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes (programmable)
  • Channels: 2 independent temperature channels
  • Probe Type: External 4-wire Pt100 probe
  • Memory Capacity: 43,000 measurement values
  • Environmental Storage Temperature/Humidity: See user manual for specific values
  • Environmental Operating Temperature/Humidity: See user manual for specific values
  • Operating Altitude: Not specified
  • ID Number: Unique identifier for each module

Product Usage Instructions

Power Supply

Ensure to use 3 AA Alkaline batteries. Follow the safety instructions provided in the manual for battery handling.

Probe Connection

Connect the external 4-wire Pt100 probe to the designated port on the module. Ensure proper connection for accurate measurements.

Logging and Communication Interval

Set the desired logging interval using the software. Note that the interval chosen will impact the battery life of the device.

Memory Management

Monitor the memory capacity of the module to avoid data loss. Download stored data periodically if needed.

Environmental Considerations

Maintain the recommended environmental storage and operating conditions to ensure accurate measurements and prolong the product lifespan.

Frequently Asked Questions

  • Q: How often should I replace the batteries?
    • A: The batteries should be replaced all at once every time, and expired batteries should be removed immediately. Follow the guidelines in the manual to ensure proper battery usage.
  • Q: What is the maximum length for probe extension?
    • A: The maximum extension for the probe is 17 meters without shielding. Ensure to follow the specifications for correct usage.

Conformity and Symbols Used

ELPRO-1THR -Humidity -Temperature -Probe-FIG (1) Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 2PTR

868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG- PRO_2PTR_DOC_Conformity_1000279V01.pdf

 

Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 1THR

868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG- PRO_1THR_DOC_Conformity_1000281V01.pdf

 

Above mentioned products operate in the 863-870MHz band with a maximum radiated output power of +11.6dBm.

ELPRO-1THR -Humidity -Temperature -Probe-FIG (2) ECOLOG-PRO 2PTR 915 MHz and ECOLOG-PRO 1THR 915 MHz

Above mentioned devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Above mentioned devices operate in the 902-928MHz band with a maximum radiated output power of +4dBm.

ECOLOG-PRO 2PTR 915 MHZ contains

FCC ID: S9NSPSGRFC IC: 8976C-SPSGRFC

ECOLOG-PRO 1THR 915 MHz contains

FCC-ID: S9NSPSGRFC IC: 8976C-SPSGRFC

ELPRO-1THR -Humidity -Temperature -Probe-FIG (3) Devices have to be disposed of according to WEEE (Waste Electrical and Electronic Equipment, 2002/96/EC).

 

System Overview

The ECOLOG-PRO measurement and communication modules described in this document are used for temperature monitoring. The measured values are transmitted to a monitoring software, which stores and analyzes the data, provides alerts if alarm limits are violated, and generates reports. The system provides superior visibility and transparency in meeting GxP requirements. The sensor-based monitoring software is easily accessible via a web browser and is also used to configure the measurement modules and sensors. The following pages contain key features and technical specifications of ECOLOG-PRO 2PTR and ECOLOG-PRO 1THR. In addition, you will find information on how to connect the modules. For detailed software and connection support, please visit our online knowledge base at https://www.elpro.com/support/ and online manuals at https://elproag.atlassian.net/wiki/spaces/POM.

ELPRO-1THR -Humidity -Temperature -Probe-FIG (4)

Measurement Module ECOLOG-PRO 2PTR

ELPRO-1THR -Humidity -Temperature -Probe-FIG (5)

Functional characteristics:

ECOLOG-PRO 2PTR is a measurement module with two external temperature sensors. Communication from this module with the ECOLOG-PRO RBR is via radio signal.

Power supply 3 AA Alkaline batteries

 

SAFETY INSTRUCTIONS!

Improper use or misuse of batteries may result in leakage of battery fluid or, in the worst case, explosion and/or fire. Please note:

Always choose the correct type of battery that best suits your intended use (see ‘Measurement range’).

So that battery status can be determined correctly, always insert new, unused batteries when changing batteries.

Never insert different types of batteries into the device at the same time.

All batteries should be replaced at the same time. Mixing old and new batteries may cause the batteries to leak and damage the product.

Make sure that the battery contacts and mating contacts in the device are clean before inserting the batteries.

Make sure that the batteries are inserted properly i.e. observe polarity (+ and -).

Remove the batteries if you are not going to use the product for a longer period of time to avoid damage from leakage. Leaking or damaged batteries can cause acid burns on skin contact. When handling damaged batteries, you should wear protective gloves.

Remove expired batteries immediately from the device.

Do not disassemble batteries, do not short-circuit them and do not throw them into fire. Never try to charge non-rechargeable batteries. There is a danger of explosion!

Keep batteries out of reach of children. Do not leave batteries lying

around as they may be swallowed by children or pets.

Battery life 14 months (provided that the module’s radio connection is stable and that the

defined temperature range (see below) is maintained)

Case / Dimensions ABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch)
Measurement range -200 °C..+200 °C
Measurement resolution 0.1 °C
Measurement accuracy ±0.2 °C
Logging and communication interval 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software

NOTE: Logging interval will impact battery life

Channels 2 independent temperature channels with separately connected sensors
Probe type External 4-wire Pt100 probe
Probe connection Standard probe: Pt100 temperature sensor, 3m cable, no shielding

Extension: maximum 17 meters, no shielding

Memory capacity 43’000 measurement values
Environmental storage temperature / humidity -10 °C..+50 °C

10 %RH..90 %RH, non-condensing

Environmental operating temperature

/ humidity

0 °C..+40 °C

10 %RH..90 %RH, non-condensing

Operating altitude This device must not be used at altitudes higher than 2000 meters above sea

level.

ID number “Q” followed by a 6-digit number; the ID number is used to identify the module in

the software.

Radio connection to communication module Available in two versions: 868 MHz (Europe) or 915 MHz (US) Note: Only the supplied antenna may be used.
Left LED (Link): Red flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but is not connected to a communication module ECOLOG-PRO RBR.

 

Yellow flashing light (1s flashing interval): ECOLOG-PRO 2PTR is currently receiving its registration information. Please wait for green light.

 

Green flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK.

 

Yellow flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but registration was not successful and has to be started again by pressing the pairing button shorty (for less than 1s).

Right LED (Data): Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement.

 

Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK.

How to connect

ELPRO-1THR -Humidity -Temperature -Probe-FIG (6)

When using the software ELPRO Cloud: Make sure that you have defined the sensor’s settings in the software and that the sensor configuration shows the image displayed above. This gives you a 10 minutes time frame to connect your module via the following steps:

  1. Remove the screw on the front and open the measurement module’s cover.
  2. Insert the three AA batteries.
  3. Bring the measurement module ECOLOG-PRO 2PTR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software.
  4. Press and hold the “Connect” button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times.
    • 4a. Wait until the left LED starts flashing red (once per second).
    • 4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterwards, the left LED will flash green every 10 seconds.
  5. Close the communication module’s cover and tighten the screw. Place the module in its intended location (e.g. storage room, next to your ultra-freezer or cryo container, etc.).

When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made.

Measurement Module ECOLOG-PRO 1THR

ELPRO-1THR -Humidity -Temperature -Probe-FIG (7)

Functional characteristics:

ECOLOG-PRO 1THR is a measurement module with one external combination probe for temperature and relative humidity. Communication from this module with the ECOLOG-PRO RBR is via radio signal.

Power supply 3 AA Alkaline batteries

 

SAFETY INSTRUCTIONS!

Improper use or misuse of batteries may result in leakage of battery fluid or, in the worst case, explosion and/or fire. Please note:

§  Always choose the correct type of battery that best suits your intended use (see ‘Measurement range’).

§  So that battery status can be determined correctly, always insert new, unused batteries when changing batteries.

§  Never insert different types of batteries into the device at the same time.

§  All batteries should be replaced at the same time. Mixing old and new batteries may cause the batteries to leak and damage the product.

§  Make sure that the battery contacts and mating contacts in the device are clean before inserting the batteries.

§  Make sure that the batteries are inserted properly i.e. observe polarity (+ and -).

§  Remove the batteries if you are not going to use the product for a longer period of time to avoid damage from leakage. Leaking or damaged batteries can cause acid burns on skin contact. When handling damaged batteries, you should wear protective gloves.

§  Remove expired batteries immediately from the device.

§  Do not disassemble batteries, do not short-circuit them and do not throw them into fire. Never try to charge non-rechargeable batteries. There is a danger of explosion!

Keep batteries out of reach of children. Do not leave batteries lying around as

they may be swallowed by children or pets.

Battery life 14 months (provided that the module’s radio connection is stable and that the

defined temperature range (see below) is maintained)

Case / Dimensions ABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch)
Measurement range and accuracy Sensor data
Measurement resolution 0.1 °C
Logging and communication interval 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software

NOTE: Logging interval will impact battery life

Channels 2 channels (1x temperature / 1x humidity)
Probe type Digital probe
Probe connection Digital 3-PIN combination probe

Extension: maximum 10 meter cable, no shielding

Memory capacity 43’000 measurement values
Environmental storage temperature / humidity -10 °C..+50 °C

10 %RH..90 %RH, non-condensing

Environmental operating temperature

/ humidity

0 °C..+40 °C

10 %RH..90 %RH, non-condensing

Operating altitude This device must not be used at altitudes higher than 2000 meters above sea

level.

ID number “R” followed by a 6-digit number; the ID number is used to identify the module in

the software.

Radio connection to communication module Available in two versions: 868 MHz (Europe) or 915 MHz (US) Note: Only the supplied antenna may be used.
Left LED (Link): Red flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but is not connected to a communication module ECOLOG-PRO RBR.

 

Yellow flashing light (1s flashing interval): ECOLOG-PRO 1THR is currently receiving its registration information. Please wait for green light.

 

Green flashing light (10s flashing interval): ECOLOG-PRO 1THR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK.

 

Yellow flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but registration was not successful and must be restarted by pressing the pairing button shorty (for less than 1s).

Right LED (Data): Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement.

 

Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK.

How to connect

ELPRO-1THR -Humidity -Temperature -Probe-FIG (8)

When using the software ELPRO Cloud: Make sure that you have defined the sensor’s settings in the software and that the sensor configuration shows the image displayed above. This gives you a 10 minutes time frame to connect your module via the following steps:

  1. Remove the screw on the front and open the measurement module’s cover.
  2. Insert the three AA batteries.
  3. Bring the measurement module ECOLOG-PRO 1THR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software.
  4. Press and hold the “Connect” button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times.
    • 4a. Wait until the left LED starts flashing red (once per second).
    • 4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterward, the left LED will be flashing green every 10 seconds.
  5. Close the communication module’s cover and tighten the screw. Place the module in its intended location (e.g. laboratory, storage room, etc.).

When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made.

Sensor data

ELPRO-1THR -Humidity -Temperature -Probe-FIG (9)

ELPRO-1THR -Humidity -Temperature -Probe-FIG (10)Part. No. 802209

Temperature & humidity sensor, capacitive This sensor is designed to monitor storage rooms, laboratories or for general room-climate monitoring.

Specifications

  • Measurement range
  • Humidity: 20 %RH..80 %RH
  • Temperature: -20 °C..80 °C
  • Humidity accuracy 15.0 °C..30.0 °C ±2.0 %RH
  • Temperature accuracy 65.0 °C..80.0 °C ±0.5 C
    • 0.0 °C..64.9 °C ±0.3 C
    • -20.0 °C..-0.1 °C ±0.5 C
  • Drift Humidity sensor Typically 3 %RH / year

ELPRO-1THR -Humidity -Temperature -Probe-FIG (11)Part. No. 802363

Temperature & humidity sensor, electrolytic

This sensor is designed for:

  • Environments with aggressive gases at high temperatures and air humidity (stability chambers, incubators)
  • Low-temperature environments (refrigerator)
  • High-precision measurements of ±0.5 %RH

Specifications

  • Measurement range
  • Humidity: 0 %RH..100 %RH
  • Temperature: -20 °C..80 °C
  • Humidity accuracy
    • 50.0 °C..80.0 °C ±2.5 %RH
    • 30.0 °C..49.9 °C ±0.8 %RH
    • 15.0 °C..29.9 °C ±0.4 %RH
    • 0.0 °C..14.9 °C ±0.8 %RH
    • -20.0 °C..-0.1 °C ±2.5 %RH
  • Temperature accuracy
    • 65.0 °C..80.0 °C ±0.2 C
    • 0.0 °C..64.9 °C ±0.1 C
    • -20.0 °C..-0.1 °C ±0.2 C
  • Drift Humidity sensor Typically < 1 %RH / year

Disposal

a) Product

ELPRO-1THR -Humidity -Temperature -Probe-FIG (12)Electronic devices are recyclable and do not belong in the household waste. Dispose of the product at the end of its service life in accordance with applicable laws. Remove any batteries and dispose of them separately from the product.

b) Batteries

ELPRO-1THR -Humidity -Temperature -Probe-FIG (13)You are legally obliged to dispose of all used batteries according to applicable laws; disposal via household waste is prohibited. Batteries categorized as containing hazardous material are marked with the adjacent symbol, under which is printed the chemical symbol for the heavy metal (Cd = cadmium, Hg = mercury, Pb = lead) used. You can dispose of used batteries at collection points in your local community. Please help protect our environment and dispose of batteries properly.

Declaration of Conformity

EU Declaration of Conformity

ELPRO-1THR -Humidity -Temperature -Probe-FIG (14) ELPRO-1THR -Humidity -Temperature -Probe-FIG (15)

EU Declaration of conformity

ELPRO-1THR -Humidity -Temperature -Probe-FIG (16)ELPRO-1THR -Humidity -Temperature -Probe-FIG (17)

ELPRO-1THR -Humidity -Temperature -Probe-FIG (18)

Documents / Resources

ELPRO 1THR Humidity Temperature Probe [pdf] Instruction Manual
2PTR, 1THR, 1THR Humidity Temperature Probe, 1THR, Humidity Temperature Probe, Temperature Probe, Probe

References

Leave a comment

Your email address will not be published. Required fields are marked *