Instruction Manual for ELPRO models including: 2PTR, 1THR, 1THR Humidity Temperature Probe, 1THR, Humidity Temperature Probe, Temperature Probe, Probe
ECOLOG-PRO 1THR
868 MHz
File Info : application/pdf, 15 Pages, 1.67MB
DocumentDocumentECOLOG-PRO Radio Modules ECOLOG-PRO 2PTR ECOLOG-PRO 1THR Operation Manual PM | MASCHL 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 1 / 15 Contents 1. System Overview .............................................................................................................................. 4 2. Measurement Module ECOLOG-PRO 2PTR...................................................................................... 5 3. Measurement Module ECOLOG-PRO 1THR ..................................................................................... 8 4. Disposal .......................................................................................................................................... 12 5. Declaration of Conformity.............................................................................................................. 13 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 2 / 15 Conformity and Symbols Used Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 2PTR 868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOGPRO_2PTR_DOC_Conformity_1000279V01.pdf Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 1THR 868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOGPRO_1THR_DOC_Conformity_1000281V01.pdf Above mentioned products operate in the 863-870MHz band with a maximum radiated output power of +11.6dBm. ECOLOG-PRO 2PTR 915 MHz and ECOLOG-PRO 1THR 915 MHz Above mentioned devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Above mentioned devices operate in the 902-928MHz band with a maximum radiated output power of +4dBm. ECOLOG-PRO 2PTR 915 MHZ contains FCC ID: S9NSPSGRFC IC: 8976C-SPSGRFC ECOLOG-PRO 1THR 915 MHz contains FCC-ID: S9NSPSGRFC IC: 8976C-SPSGRFC Devices have to be disposed of according to WEEE (Waste Electrical and Electronic Equipment, 2002/96/EC). 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 3 / 15 1. System Overview The ECOLOG-PRO measurement and communication modules described in this document are used for temperature monitoring. The measured values are transmitted to a monitoring software, which stores and analyzes the data, provides alerts if alarm limits are violated, and generates reports. The system provides superior visibility and transparency in meeting GxP requirements. The sensorbased monitoring software is easily accessible via a web browser and is also used to configure the measurement modules and sensors. The following pages contain key features and technical specifications of ECOLOG-PRO 2PTR and ECOLOG-PRO 1THR. In addition, you will find information on how to connect the modules. For detailed software and connection support, please visit our online knowledge base at https://www.elpro.com/support/ and online manuals at https://elproag.atlassian.net/wiki/spaces/POM. * module covered in this document 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 4 / 15 2. Measurement Module ECOLOG-PRO 2PTR Functional characteristics: ECOLOG-PRO 2PTR is a measurement module with two external temperature sensors. Communication from this module with the ECOLOG-PRO RBR is via radio signal. Power supply Battery life Case / Dimensions Measurement range Measurement resolution Measurement accuracy Logging and communication interval Channels Probe type 3 AA Alkaline batteries SAFETY INSTRUCTIONS! Improper use or misuse of batteries may result in leakage of battery fluid or, in the worst case, explosion and/or fire. Please note: Always choose the correct type of battery that best suits your intended use (see 'Measurement range'). So that battery status can be determined correctly, always insert new, unused batteries when changing batteries. Never insert different types of batteries into the device at the same time. All batteries should be replaced at the same time. Mixing old and new batteries may cause the batteries to leak and damage the product. Make sure that the battery contacts and mating contacts in the device are clean before inserting the batteries. Make sure that the batteries are inserted properly i.e. observe polarity (+ and -). Remove the batteries if you are not going to use the product for a longer period of time to avoid damage from leakage. Leaking or damaged batteries can cause acid burns on skin contact. When handling damaged batteries, you should wear protective gloves. Remove expired batteries immediately from the device. Do not disassemble batteries, do not short-circuit them and do not throw them into fire. Never try to charge non-rechargeable batteries. There is a danger of explosion! Keep batteries out of reach of children. Do not leave batteries lying around as they may be swallowed by children or pets. 14 months (provided that the module's radio connection is stable and that the defined temperature range (see below) is maintained) ABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch) -200 °C..+200 °C 0.1 °C ±0.2 °C 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software NOTE: Logging interval will impact battery life 2 independent temperature channels with separately connected sensors External 4-wire Pt100 probe 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 5 / 15 Probe connection Memory capacity Environmental storage temperature / humidity Environmental operating temperature / humidity Operating altitude ID number Radio connection to communication module Left LED (Link): Standard probe: Pt100 temperature sensor, 3m cable, no shielding Extension: maximum 17 meters, no shielding 43'000 measurement values -10 °C..+50 °C 10 %RH..90 %RH, non-condensing 0 °C..+40 °C 10 %RH..90 %RH, non-condensing This device must not be used at altitudes higher than 2000 meters above sea level. "Q" followed by a 6-digit number; the ID number is used to identify the module in the software. Available in two versions: 868 MHz (Europe) or 915 MHz (US) Note: Only the supplied antenna may be used. Red flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but is not connected to a communication module ECOLOG-PRO RBR. Yellow flashing light (1s flashing interval): ECOLOG-PRO 2PTR is currently receiving its registration information. Please wait for green light. Green flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK. Right LED (Data): Yellow flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but registration was not successful and has to be started again by pressing the pairing button shorty (for less than 1s). Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement. Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK. 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 6 / 15 How to connect When using the software ELPRO Cloud: Make sure that you have defined the sensor's settings in the software and that the sensor configuration shows the image displayed above. This gives you a 10 minutes time frame to connect your module via the following steps: 1. Remove the screw on the front and open the measurement module's cover. 2. Insert the three AA batteries. 3. Bring the measurement module ECOLOG-PRO 2PTR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software. 4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times. 4a. Wait until the left LED starts flashing red (once per second). 4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterwards, the left LED will be flashing green every 10 seconds. 5. Close the communication module's cover and tighten the screw. Place the module in its intended location (e.g. storage room, next to your ultra-freezer or cryo container, etc.). When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made. 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 7 / 15 3. Measurement Module ECOLOG-PRO 1THR front view bottom view Functional characteristics: ECOLOG-PRO 1THR is a measurement module with one external combination probe for temperature and relative humidity. Communication from this module with the ECOLOG-PRO RBR is via radio signal. Power supply Battery life 3 AA Alkaline batteries SAFETY INSTRUCTIONS! Improper use or misuse of batteries may result in leakage of battery fluid or, in the worst case, explosion and/or fire. Please note: Always choose the correct type of battery that best suits your intended use (see 'Measurement range'). So that battery status can be determined correctly, always insert new, unused batteries when changing batteries. Never insert different types of batteries into the device at the same time. All batteries should be replaced at the same time. Mixing old and new batteries may cause the batteries to leak and damage the product. Make sure that the battery contacts and mating contacts in the device are clean before inserting the batteries. Make sure that the batteries are inserted properly i.e. observe polarity (+ and -). Remove the batteries if you are not going to use the product for a longer period of time to avoid damage from leakage. Leaking or damaged batteries can cause acid burns on skin contact. When handling damaged batteries, you should wear protective gloves. Remove expired batteries immediately from the device. Do not disassemble batteries, do not short-circuit them and do not throw them into fire. Never try to charge non-rechargeable batteries. There is a danger of explosion! Keep batteries out of reach of children. Do not leave batteries lying around as they may be swallowed by children or pets. 14 months (provided that the module's radio connection is stable and that the defined temperature range (see below) is maintained) 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 8 / 15 Case / Dimensions Measurement range and accuracy Measurement resolution Logging and communication interval Channels Probe type Probe connection Memory capacity Environmental storage temperature / humidity Environmental operating temperature / humidity Operating altitude ID number Radio connection to communication module Left LED (Link): ABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch) Sensor data (page 11) 0.1 °C 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software NOTE: Logging interval will impact battery life 2 channels (1x temperature / 1x humidity) Digital probe Digital 3-PIN combination probe Extension: maximum 10 meter cable, no shielding 43'000 measurement values -10 °C..+50 °C 10 %RH..90 %RH, non-condensing 0 °C..+40 °C 10 %RH..90 %RH, non-condensing This device must not be used at altitudes higher than 2000 meters above sea level. "R" followed by a 6-digit number; the ID number is used to identify the module in the software. Available in two versions: 868 MHz (Europe) or 915 MHz (US) Note: Only the supplied antenna may be used. Red flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but is not connected to a communication module ECOLOG-PRO RBR. Yellow flashing light (1s flashing interval): ECOLOG-PRO 1THR is currently receiving its registration information. Please wait for green light. Green flashing light (10s flashing interval): ECOLOG-PRO 1THR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK. Right LED (Data): Yellow flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but registration was not successful and must be restarted by pressing the pairing button shorty (for less than 1s). Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement. Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK. 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 9 / 15 How to connect When using the software ELPRO Cloud: Make sure that you have defined the sensor's settings in the software and that the sensor configuration shows the image displayed above. This gives you a 10 minutes time frame to connect your module via the following steps: 1. Remove the screw on the front and open the measurement module's cover. 2. Insert the three AA batteries. 3. Bring the measurement module ECOLOG-PRO 1THR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software. 4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times. 4a. Wait until the left LED starts flashing red (once per second). 4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterwards, the left LED will be flashing green every 10 seconds. 5. Close the communication module's cover and tighten the screw. Place the module in its intended location (e.g. laboratory, storage room, etc.). When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made. 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 10 / 15 Sensor data Part. No. 802209 Part. No. 802363 Dimensional view of the two variants: temperature / humidity sensor Temperature & humidity sensor, capacitive This sensor is designed to monitor storage rooms, laboratories or for general room-climate monitoring. Specifications Measurement range Humidity: 20 %RH..80 %RH Temperature: -20 °C..80 °C Humidity accuracy 15.0 °C..30.0 °C ±2.0 %RH Temperature accuracy 65.0 °C..80.0 °C 0.0 °C..64.9 °C -20.0 °C..-0.1 °C ±0.5 C ±0.3 C ±0.5 C Drift Humidity sensor Typically 3 %RH / year Temperature & humidity sensor, electrolytic This sensor is designed for: Environments with aggressive gases at high temperature and air humidity (stability chambers, incubators) Low-temperature environments (refrigerator) High-precision measurements of ±0.5 %RH Specifications Measurement range Humidity: 0 %RH..100 %RH Temperature: -20 °C..80 °C Humidity accuracy 50.0 °C..80.0 °C 30.0 °C..49.9 °C 15.0 °C..29.9 °C 0.0 °C..14.9 °C -20.0 °C..-0.1 °C ±2.5 %RH ±0.8 %RH ±0.4 %RH ±0.8 %RH ±2.5 %RH Temperature accuracy 65.0 °C..80.0 °C 0.0 °C..64.9 °C -20.0 °C..-0.1 °C ±0.2 C ±0.1 C ±0.2 C Drift Humidity sensor Typically < 1 %RH / year 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 11 / 15 4. Disposal a) Product Electronic devices are recyclable and do not belong in the household waste. Dispose of the product at the end of its service life in accordance with applicable laws. Remove any batteries and dispose of them separately from the product. b) Batteries You are legally obliged to dispose of all used batteries according to applicable laws; disposal via household waste is prohibited. Batteries categorized as containing hazardous material are marked with the adjacent symbol, under which is printed the chemical symbol for the heavy metal (Cd = cadmium, Hg = mercury, Pb = lead) used. You can dispose of used batteries at collection points in your local community. Please help protect our environment and dispose of batteries properly. 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 12 / 15 5. Declaration of Conformity 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 13 / 15 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 14 / 15 ELPRO-BUCHS AG Langäulistrasse 45 9470 Buchs SWITZERLAND E-Mail: swiss@elpro.com For local agencies see: www.elpro.com 1000465V02 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 15 / 15