Danfoss KE05501 Time Proportional Amplifier Module User Guide
Danfoss KE05501 Time Proportional Amplifier Module

DESCRIPTION

The KE05 Time Proportional Amplifier Module provides automatic steering control on paving, curbing and planing machines. The KE05 receives a signal from an external potentiometer and outputs a control signal to a solenoid to position a screed, form or cutting drum.

TECHNICAL DATA

ELECTRICAL

OPERATING VOLTAGE
11 – 14 Vdc
OUTPUT CURRENT
3.5 amps, maximum
STANDBY CURRENT
100 mA, maximum
VOLTAGE MIDPOINT
Input null voltage shall be 4 Volts nominal when measured to the common on the PWB.
FREQUENCY
Within the proportional band the frequency of the output
pulses is 3±1 Hz.

ORDERING INFORMATION

Order the KE05 per the information in Table A.

TABLE A. INFORMATION NECESSARY TO ORDER THE KE05 AMPLIFIER. 

PART NUMBER MAXIMUM DEADBAND(Vdc) PROPORTIONING BAND
TERM 5              TERM 6
INPUT RATIO GAIN X TERM R35,21
KE05501 .35 .25 .25 1:1 1X No 100 Ohm
KE05502 .35 .25 .25 Nonlinear 1X No 100 Ohm
KE05503 .47 (5).25 (6) .37 .21 2:1 1X No 100 Ohm
KE05504 .16 .10± 50% .10± 50% 1:1 5X Yes 100 Ohm
KE05505 .35 .25 .25 1:1 1X No Jumpers
KE05506 .35 .25 .25 1:1 1X No 100 Ohm

NOTE: All voltage measurements ±15% unless noted otherwise. Bracketed numbers for the KE05503 refer to terminals. On the KE05506, R1 is jumpered so that summing can be done externally.

CONNECTION DIAGRAM

Connection Diagram

TECHNICAL DATA

Technical Diagram

CUSTOMER SERVICE

NORTH AMERICA

ORDER FROM
Danfoss (US) Company
Customer Service Department
3500 Annapolis Lane North
Minneapolis, Minnesota 55447
Telephone: 763-509-2084
Fax: 763-559-0108
DEVICE REPAIR
For devices in need of repair, include a description of the problem, a copy of the purchase order and your name, address and telephone number.
RETURN TO
Danfoss (US) Company
Return Goods Department
3500 Annapolis Lane North
Minneapolis, Minnesota 55447

EUROPE

ORDER FROM
Danfoss (Neumünster) GmbH & Co.
Customer Service Department
Krokamp 35
Postfach 2460
D-24531 Neumünster
Germany
Telephone: 49-4321-8710
Telex: (299) 708
Fax: 49-4321-871-284

KE05
Time Proportional Amplifier Module
BLN-95-9021-2 Issued: June 1995

Danfoss Logo

Documents / Resources

Danfoss KE05501 Time Proportional Amplifier Module [pdf] User Guide
KE05501 Time Proportional Amplifier Module, KE05501, Time Proportional Amplifier Module, Proportional Amplifier Module, Amplifier Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *