Altronix LogoVR Series
Power Conversion Modules

Overview:

The unit converts a 24VAC and/or 24VDC input into a regulated 5VDC or 12VDC output.

Reference Chart:

Altronix
Model Number
Input Output Battery
Charging
Cable
Assembly
Screw
Terminal
Spring
Terminal
VR1 24VAC/20VA or higher / 24VDC 12VDC 0 1A max.
VR1T 24VAC/20VA or higher / 24VDC 12VDC 0 1A max.
VR2T 24VAC/20VA or higher / 24VDC 12VDC 0 0.5A max.
VR3T 24VDC 12VDC 02A max.
VR4T 24VDC 12VDC 03A max.
VR5T 24VAC/50VA or higher / 24VDC 12VDC 03A max.
VR5BT 24VAC/50VA or higher / 24VDC 12VDC 03A max.
VR1TM5 16VAC/24VAC/20VA or higher /12 or 24VDC 5VDC ®1A max.

Specifications: CE SYMBOL

Agency Listing:

  • CE European Conformity.

Input:

  • Input 24VAC or 24VDC.

Output:

  • 5VDC (VR1TM5) or 12VDC output.
  • Filtered and electronically regulated output.
  • Built-in overload protection.

Applications:

  • Power for 12VDC CCTV cameras and accessories,
    Fiber Optic Transmitters, REX PIR’s, Prox Readers, etc.

Visual Indicators:

  • Power LED indicator.

Features:

  • Modular connector/cable assembly facilitates ease of wiring.
  • Compact design allows for integration in a wide range of camera housings.
    Dimensions (W x D x H approx.):
    VR5T / VR5BT:
    3.375” x 2.5” x 1.125” (85.7mm x 63.5mm x 28.6mm) All other units:
    1.625” x 2.375” x 1” (41.3mm x 60.3mm x 25.4mm)

Installation Instructions:

Installing VR1 (Fig. 1, pg. 1):

  1. Mount unit in proximity to the device. Affix one side of velcro (supplied) to the unit and place the second side of the velcro in the desired location.
  2. Connect Yellow lead and Purple lead to 24VAC transformer or 24VDC power source*.
  3. Measure output voltage and check polarity before connecting devices, in order to avoid potential damage.
  4. Connect Red lead [Pos. +] and Black lead [Neg. –] to device to be powered.
  5. LED will illuminate when power is present.
    * For CE compliance use a Class 2 Power-Limited Power Source.

Altronix VR Series Power Conversion Modulesaltronix.com

Installing VR1T, VR1TM5, VR2T (Figs. 2-4, pg. 2):

  1. Mount unit in proximity to the device. Affix one side of velcro (supplied) to unit and place the second side of the velcro in the desired location.
  2. Connect 24VAC transformer or 24VDC source* to the terminals marked [24VDC/24VAC Input].
  3. Measure output voltage and check polarity before connecting devices, in order to avoid potential damage.
  4. Connect device to be powered to the terminals marked [+ Output –].
  5. LED will illuminate when power is present.
    * For CE compliance use a  Class 2 Power-Limited  Power Source.

Altronix VR Series Power Conversion Modules - Fig

Installing VR3T, VR4T (Figs. 5-6, pg. 2):

  1. Mount unit in proximity to the device. Affix one side of velcro (supplied) to the unit and place the second side of the velcro in the desired location.
  2. Connect 24VDC source* to the terminals marked [24VDC + Input –].
  3. Measure output voltage and check polarity before connecting devices, in order to avoid potential damage.
  4. Connect device to be powered to the terminals marked [– Output +].
  5. LED will illuminate when power is present.
    * For CE compliance use a Class 2 Power-Limited Power Source.

Altronix VR Series Power Conversion Modules - Fig 1

Installing VR5T, VR5BT (Figs. 7-8, pg. 2):

  1. Mount unit in proximity to the device. Use a proper fastener and/or wall anchor when securing unit to the wall.
  2. Connect 24VAC transformer or 24VDC source* to the terminals marked [Input].
  3. Measure output voltage and check polarity before connecting devices, in order to avoid potential damage.
  4. Connect device to be powered to the terminals marked [– OUT + ].
  5. LED will illuminate when power is present.
  6. For VR5BT (Fig. 8, pg. 2) – when the use of stand-by batteries is desired, they must be lead acid or gel type. Connect battery to terminals marked [– BAT +].
    * For CE compliance use a Class 2 Power-Limited Power Source.

Altronix VR Series Power Conversion Modules - Fig 2

Altronix is not responsible for any typographical errors.
Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA |
phone: 718-567-8181 |
fax: 718-567-9056 web site: www.altronix.com |
e-mail: info@altronix.com |
Lifetime Warranty |
Made in U.S.A. IIVRseries – Rev. 070709 F23U
Altronix Logo 1

Documents / Resources

Altronix VR Series Power Conversion Modules [pdf] Instruction Manual
VR Series, Power Conversion Modules, Conversion Modules, Power Modules, Modules, VR Series