NEMA 14-50 50 AMP RECEPTACLE ASSEMBLY
- Remove 2.5” of the outer jacket and strip off 0.5“ of the inner jacket on the green wire.
- Cut the red and black wires to 3.125” and strip off 0.5” of the inner jackets.
- Cut the white wire to 3.785” and strip off 0.5” of the inner jacket.
- Before wiring, be sure to put the strain relief back on the cable. DO NOT re-attach the cable clamp yet.
- Attach each wire to their proper terminal. The green should be last and is easiest to attach when it is going straight ahead into the ground prong.
- The cable clamp now goes back into place.
- Put the handle back into place.
- Put the back cover into place.
- Tighten screws
When making connections, make certain they are secure, properly insulated, and there are no stray wire strands outside the terminals. Tighten the terminal screws to 12-16 in-lbs torque. Tighten the cord clamp assembly screws to a maximum 10-12 in-lbs torque. Lastly tighten the assembly screws.