Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-logo

Alarm System Store SEM210 Dual Path System Enhancement Module

Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-chigadzirwa

IMIrairo AKARERUDZWA KUBVA KUBVA KWAKO ANOSHAMWARIDZANA NEMBORO MBORO YECHIKAMU

Isu takanyora bhuku rakareruka rekuisa kune vatengi vedu netarisiro yekuti tinogona kudzoreredza matambudziko ese tichiisa yako SEM210. Kutevera iyi dhairekitori yekuraira kunokupa iwe wakanakisa mukana wekumisikidza yako Alarm.com mutauriri pasina kumbobvira wasvika kune chero rubatsiro. Kana iwe uine chero matambudziko kana mibvunzo zvakadaro, ndapota inzwa wakasununguka kutitumira email pa alarms@alarmsystemstore.com uye tichaita zvese zvatinogona kuti tikubatsire.

STEP GUIDE

  1. TENGA ALARM.COM SERVICE UYE ZADZA MAFOMU ANODIWA
  2. DISARM PANEL UYE SIMBA PASI
  3. WAYA SEM KUTI PANEL
  4. SIMBA SYSTEM UP UYE BVIRIRA iyo SEM KUTI KUBANISA KUTI PANEL
  5. TARIDZA ZONE LABELS YAKO
  6. TUMA A SYSTEM TEST SIGNAL
  7. NADZWA YAKO ITSVA ALARM.COM INTERACTIVE SERVICE

KUTI UONE Vhidhiyo DZIDZISO YEIYI KUGADZIRIRA MAITIRO, ONA QR CODE APA

STEP 1: Usati watanga

  1. TENGA ALARM.COM INTERACTIVE SERVICE KUBVA KU ALARM SYSTEM STORE UYE KUPEDZA MIRAYIRIRO MUKUITA EMAIL.
  2. ONA shuwa kuti une ZVINHU ZVINHU ZVOSE ZVINODIWA KUTI WAKO SEM210 INSTALLATION.Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-fig-1

CHECHI 2: DISA SYSTEM UYE SIMBA

DISARM NE SIMBA PASI PANEL

  1. Wona kuti pani yakatorerwa zvombo uye haina maalarm, matambudziko, kana kukanganisa system.
  2. Kana iwe usingazive iyo yazvino kodhi yekuisa, tarisa iyo yekuisa kodhi pane pani usati waisa simba pasi pani.
  3. Wobva wabvisa iyo AC simba uye bvisa bhatiri rekuchengetedza kuti unyatso kudzika pasi system.

CHECHITATU: KUbatanidza SEM

WIRING
Zvakakosha: Kana usingazivi kuti izvi zvinorevei, rega kuteerera mutsara uyu. Alternate wiring inodiwa kana uchishandisa mudziyo uyu kuisirwa ETL. (+12v waya kubva kuSEM ichaenda kune +12V terminal pane pani)Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-fig-2

KUTI WAYA PANEL

  1. Batanidza mapaneru terminal 4 (GND) kuSEM GND, panel terminal 6 (GREEN: DATA IN FROM KEYPAD) kusvika GREEN (OUT), uye panel terminal 7 (YELLOW: KEYPAD DATA OUT) kusvika YELLOW (IN).
  2. Uchishandisa tambo tsvuku yakabatanidzwa ine maviri-prong bhatiri yekubatanidza, batanidza bhatiri kune ese SEM uye pani. Kune yemagetsi-asina simba redunhu, ita shuwa kuti fuse iri mukati meVista panel.
  3. Batanidza tambo yeEthernet kune yaungasarudza Ethernet dongle kushandisa Dual-Path kutaurirana. Shanduko dzemambure emunharaunda dzinogona kudiwa nzira yebroadband isati yatanga.
  4. Bvisa snap-off mapurasitiki kubva kudivi rakavharirwa panzvimbo dzaunoda, wobva waendesa iyo
    tambo dzakatenderedza mukati memukati dhizaini madziro uye kunze kwedivi rekuvharirwa.
  5. Usati wapedza kuisa, tarisa kuti wiring connections dzakachengeteka uye kuti zvese zvemukati zviri munzvimbo yazvo chaiyo.
  6. Wobva wavhara pakavharwa nekutsveta chivharo munzvimbo dzinokwirisa kumusoro kwegasi rekuvharirwa wobva warovera pasi chivharo kuti utore zvigunwe zvigunwe panzvimbo.

Nhanho 4: SIMBA SYSTEM UP UYE VUMBIRA ZVINHU ZVIKANGANANA NEPANELE.

Batanidza bhatiri rekuchengetedza uye dzorera simba re AC kune pani. Kuti iyo SEM idyidzane nenzvimbo dziripo pane system, inofanirwa kudziverenga kubva kuPowerSeries pani. Iyo SEM inoita zone scan kuti iverenge ruzivo urwu.Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-fig-3

ZONE SCAN -10 maminetsi Usabata panhi kana keypad.

Iyo zone scan inotanga otomatiki mukati meminiti imwe mushure mekunge pani yasimudzwa uye inofanira kutora pakati pe5 ne15 maminetsi, zvichienderana nehuwandu hwezvikamu uye nzvimbo pane system. Usabate panhi, keypad, kana SEM, panguva ino. Iyo zone scan inokwana kana mwenje yegirinhi neyero pakiyipadhi ichiramba yakasimba. Kana ukadzvanya chero mabhatani pakiyipadhi panguva yekutarisa zone, meseji Sisitimu haisi kuwanikwa inoratidzwa pachiratidziri. Zuva uye nguva zvinoratidzwa pachiratidziro kana zone scan yapera.
Zvakakosha: Kana sisitimu yaimbotaura parunhare, tinokurudzira Disabling Telco Line Monitoring (Chikamu 015, Sarudzo 7) uye Kubvisa Nhamba dzerunhare (Chikamu 301-303).

nhanho 5: BROADCAST ZONE LABELS

Kuti iyo SEM ikwanise kuverenga mazita ekunzwa akachengetwa papanera uye woaratidza paAlarm.com, unofanirwa kutepfenyura mazita enzwa akachengetwa pamakiyipadhi. Izvi zvinofanirwa kuitwa kune yega yega yekuisirwa neLCD keypad uye inodiwa kunyangwe paine keypad imwe chete pane system.Alarm-System-Store -SEM210-Dual-Path-System-Enhancement-Module-fig-4 Broadcast sensor mazita nekusarudza zvinotevera: []+[8]+ [Installer Code] + [*] kupinda muLCD programming. Kubva paLCD programming, enda kundima 998 wodzvanya [] kutepfenyura mazita enzwa.

STEP 6: TUMA SYSTEM TEST

Mushure mekunge waisa yako SEM210, email alarms@alarmsystemstore.com yako IMEI nhamba kubva kucommunicator pamwe neodha yako nhamba. Ivo vanokupa mirairo yekupedzisa yako system bvunzo uye kuseta yako Alarm.com account. Iwe zvakare uchagamuchira "Tanga" email. Siya iyi email sezvairi kusvika matanho anotevera apera.

SYSTEM TEST

  • Kuti uite zvizere sevhisi yako uye sync kumusoro kwepaneru uye mutauri kune iyo Alarm.com account, iwe unozofanirwa kutumira bvunzo yesystem kubva papaneru. Kuita izvi tevera matanho aya: - Dzvanya * 6 + (master kodhi kana zvichidikanwa) - Uchishandisa > bhatani, penya kurudyi kune sarudzo 4 (system test) - Dzvanya *
  • Siren icharira kwechinguva, uye sisitimu inotumira chiratidzo chebvunzo.
  • Mushure mekunge mamhanyisa iyo system test email alarms@alarmsystemstore.com kusimbisa kutumira kwechiratidzo. Kana vakagamuchira chiratidzo chako, iwe unogona ikozvino kutevera iyo "Tanga" link kubva kune email yataurwa pamusoro.
  • KANA UNE CENTRAL STATION ACCOUNT YAURI KUSHANDISA SAKA, UNOGONA KUENDERERA MUKUITA NEKUIYEDZA. RUBATIRO RWEDU VECUSTOMER (alarms@alarmsystemstore.com) ICHAKUZIVISA PANE MAITIRO EKUEDZA SYSTEM YAKO UYE KUPEDZA KUITA KWAKO.
  • MAKOROKOTO! WAKUSISA YAKO SEM210! WAGADZIRA FORSTEP7: NADZWA NE ALARM YAKO.COMINTERACTIVEPLAN

Zvinyorwa / Zvishandiso

Alarm System Store SEM210 Dual Path System Enhancement Module [pdf] Installation Guide
SEM210, Dual Path System Enhancement Module, Enhancement Module, Dual Path System Module, Module, SEM210

References

Siya mhinduro

Yako email kero haizoburitswa. Nzvimbo dzinodiwa dzakamakwa *