MegaTec Net485-Y Ethernet Device Server
Folasaga
Vaega
Net485 is to convert RS232 signals of [MegaTec] and other protocols to RS422 or RS485 signals.
Vaega:
- CPU is ARM 266MHz 32Bit, system clock is 208MHz, flash memory is 4M, SDRAM is 16M, and built-in watchdog.
- Net485 normal operating temperature and humidity range is 0℃ to 50℃ and 5% to 95%.
- FCC, Class B, CE, Rosh approved.
Fa'amatalaga Malosiaga
Aitema | Laiti | maualuga |
DC sao Voltage | +5.3V | +40V |
DC Input Current | 3W Maualuga |
Pin Tofiga
Pin | Faʻasalaga / Galuega | Fa'amatalaga |
P1 GND | GND | PIN eleele |
P2 Power In | Ulufale | DC mana fa'aoga |
P3 RS232_TXD | Tuuina atu | +5.5V and -5.5V Voltage maualuga mo RS232 |
P4 RS232_RXD | Ulufale | -3V to -15V for logic ‘1’, +3V to +15V for logic ‘0’ |
P5-P7 No USE | ||
P8 SNMPSIG | NET485 card plug in detect, connect to PIN 10 | |
P9 GND | GND | PIN eleele |
P10 SNMPSIG | NET485 card plug in detect, connect to PIN 8 | |
P11 RS232_DCD | Ulufale | +/-3V to +/-15V for RS232 |
P12 RS232_DTR | Tuuina atu | +5.5V and -5.5V for RS232 |
P13 RS232_DSR | Ulufale | +/-3V to +/-15V for RS232 |
P14 RS232_RTS | Tuuina atu | +5.5V and -5.5V for RS232 |
P15 RS232_CTS | Ulufale | +/-3V to +/-15V for RS232 |
P16 RS232_RI | Ulufale | +/-3V to +/-15V for RS232 |
P17-P26 No Use |
Fa'amatalaga Fa'ailoga
Fa'aulufalega
PARAMETER | TULAGA | MIN | TYP | MAX |
Sao Voltagu lautele | -25V | +25V | ||
Fa'alumaina Fa'aulu maualalo | TA=±25℃ | +0.6V | +1.2V | |
Uluai Fa'aulu | TA=±25℃ | +1.5V | +2.4V | |
Input Hysteresis | 0.3V | |||
Fa'asagaga Fa'aulu | TA=±25℃ | 3k ohm | 5k ohm | 7k ohm |
Fa'aliliuga Fa'amatalaga
PARAMETER | TULAGA | MIN | TYP | MAX |
Galuega Faatino Voltagu Sulu | All transmitter outputs loaded with 3k ohm to ground | ±5.0V | ±5.4V | |
Fa'asagaga Fa'atino | TA=±25℃ | 300 | 10M | |
La'au Pu'upu'u | ±35mA | ±60mA | ||
I le taimi nei |
Fua Fa'amatalaga
Net485-Y Pepa Totonu
Fua | 137.7mm(L) × 60mm(W) × 43.0mm(H) |
mamafa | 53g±2g |
Feso'ota'i | 26 pine tamatamailima auro |
Net485-Y Kata i fafo
Fua | 156mm(L) × 82mm(W) × 32mm(H) |
mamafa | 195g±2g |
Net485-Y Adapter
Fua | 42.15mm(L) × 31.08mm(W) × 17.38mm(H) |
mamafa | 12.8g±2g |
Fa'aoga
Falegaosimea
Net485 will be set according to the parameters related to the receiving data side provided by the user before shipping. Because the Net485 parameter setting requires the user to use a direct serial cable (1 to 1, 2 to 2… 9 to 9) connected to the computer side and set up using HyperTerminal. The external card requires the user to remove the case. To see the advanced user settings,
Fa'amolemole fa'afeso'ota'i la matou lagolago fa'apitoa.
E manaʻomia e tagata faʻaoga masani ona tuʻuina atu faʻasologa o loʻo i lalo i le pito e maua ai i la matou kamupani e fai ai fale gaosimea;
RS232 | RS422 | RS485 | |
Tulaga o masini | 01(Toe Taua) | 01 | 01 |
MODBUS Connection Mode | RTU (Taua Fa'atatau) | RTU | RTU |
RS Baud Rate | 9600(Toe Taua) | 9600 | 9600 |
RS So'oga Ituaiga | RS232 (Default Value) | RS485 | RS485 |
Half Duplex / Full Duplex | Full Duplex (Default Value) | Full Duplex | Half Duplex |
Feso'ota'iga Fa'asologa Tulaga Fa'aeletise | Faiga masani (Toe Taua) |
Faiga masani | Faiga masani |
Talosaga
Users can connect Net485 to UPS and MODBUS receiver or PC for testing.
O mea o lo'o mulimuli mai o se fa'ata'ita'igaample of [Modscan] software testing.
If you connect Net485 to PC side for testing, you need to prepare your own RS485 to RS232 cable. You can refer to the following diagram for the connection method.
- Run [Modscan], click Connection, select the PC serial port connected to the Net485 output, and Modbus related settings. As shown in the figure.
- Select the holding register and start address to view o fa'amaumauga na maua.
- Look up the UPS data represented by the corresponding address bit in the provided register address file.
Pepa / Punaoa
![]() |
MegaTec Net485-Y Ethernet Device Server [pdf] Tusi Taiala Net485, Net485-Y, MegaTec 2023-7-6, Net485-Y Ethernet Device Server, Net485-Y, Ethernet Device Server, Device Server |