ميگا ٽيڪ نيٽ 485-وائي ايٿرنيٽ ڊيوائس سرور

ميگا ٽيڪ نيٽ 485-وائي ايٿرنيٽ ڊيوائس سرور

تعارف

خاصيتون

Net485 is to convert RS232 signals of [MegaTec] and other protocols to RS422 or RS485 signals.

خاصيتون:

  1. CPU is ARM 266MHz 32Bit, system clock is 208MHz, flash memory is 4M, SDRAM is 16M, and built-in watchdog.
  2. Net485 normal operating temperature and humidity range is 0℃ to 50℃ and 5% to 95%.
  3. FCC, Class B, CE, Rosh approved.
پاور وضاحتون
شيءِ گھٽ ۾ گھٽ وڌ ۾ وڌ
ڊي سي ان پٽ Voltage +5.3V +40V
ڊي سي ان پٽ ڪرنٽ 3W وڌ ۾ وڌ
پن کي تفويض
پن انٽيپشن / ٻاھران وصف
P1 GND جي اين ڊي گرائونڊ پن
P2 Power In ان پٽ ڊي سي پاور ان پٽ
P3 RS232_TXD ٻاھر +5.5V and -5.5V Voltage level for RS232
P4 RS232_RXD ان پٽ -3V to -15V for logic ‘1’, +3V to +15V for logic ‘0’
P5-P7 No USE
P8 SNMPSIG NET485 card plug in detect, connect to PIN 10
P9 GND جي اين ڊي گرائونڊ پن
P10 SNMPSIG NET485 card plug in detect, connect to PIN 8
P11 RS232_DCD ان پٽ +/-3V to +/-15V for RS232
P12 RS232_DTR ٻاھر +5.5V and -5.5V for RS232
P13 RS232_DSR ان پٽ +/-3V to +/-15V for RS232
P14 RS232_RTS ٻاھر +5.5V and -5.5V for RS232
P15 RS232_CTS ان پٽ +/-3V to +/-15V for RS232
P16 RS232_RI ان پٽ +/-3V to +/-15V for RS232
P17-P26 No Use
Signal Specification

وصول ڪندڙ ان پٽ 

PARAMETER حالتون منٽ ٽائيپ MAX
انٽ واليمtage حد -25V +25V
داخل ٿيڻ جي حد گھٽ ٽي اي = ± 25 ℃ +0.6V +1.2V
ان پٽ جي حد اعلي ٽي اي = ± 25 ℃ +1.5V +2.4V
ان پٽ Hysteresis 0.3V
ان پٽ مزاحمت ٽي اي = ± 25 ℃ 3k ohm 5k ohm 7k ohm

ٽرانسميٽر آئوٽ پُٽ

PARAMETER حالتون منٽ ٽائيپ MAX
اوٽ وولٽtage جھول All transmitter outputs loaded with 3k ohm to ground ±5.0V ±5.4V
پيداوار جي مزاحمت ٽي اي = ± 25 ℃ 300 10 ايم
آئوٽ پٽ شارٽ سرڪٽ ±35mA ±60mA
موجوده
سائيز جي وضاحت

Net485-Y Internal Card 

طول و عرض 137.7mm(L) × 60mm(W) × 43.0mm(H)
وزن 53g±2g
ڳنڍيندڙ 26pin gold finger

Net485-Y Internal Card

Net485-Y External Card 

طول و عرض 156mm(L) × 82mm(W) × 32mm(H)
وزن 195g±2g

Net485-Y Internal Card

Net485-Y Adapter

طول و عرض 42.15mm(L) × 31.08mm(W) × 17.38mm(H)
وزن 12.8g±2g

Net485-Y Adapter

استعمال

فيڪٽري سيٽنگون

Net485 will be set according to the parameters related to the receiving data side provided by the user before shipping. Because the Net485 parameter setting requires the user to use a direct serial cable (1 to 1, 2 to 2… 9 to 9) connected to the computer side and set up using HyperTerminal. The external card requires the user to remove the case. To see the advanced user settings,
مهرباني ڪري اسان جي ٽيڪنيڪل سپورٽ سان رابطو ڪريو.

Ordinary users need to provide the following parameters at the receiving end to our company to make factory settings;

RS232 RS422 RS485
ڊوائيس جو پتو 01(Default Value) 01 01
MODBUS Connection Mode RTU (Default Value) آر ٽي يو آر ٽي يو
RS Baud Rate 9600(Default Value) 9600 9600
RS Connection Type RS232 (Default Value) RS485 RS485
Half Duplex / Full Duplex Full Duplex (Default Value) مڪمل ڊپلڪس اڌ ڊپلڪس
Serial Communication Electrical Level عام موڊ
(ڊفالٽ قدر)
عام موڊ عام موڊ

درخواستون

Users can connect Net485 to UPS and MODBUS receiver or PC for testing.
هيٺ ڏنل مواد هڪ اڳوڻي آهيample of [Modscan] software testing.

If you connect Net485 to PC side for testing, you need to prepare your own RS485 to RS232 cable. You can refer to the following diagram for the connection method.

درخواستون

  1. Run [Modscan], click Connection, select the PC serial port connected to the Net485 output, and Modbus related settings. As shown in the figure.
    درخواستون
    درخواستون
  2. Select the holding register and start address to view حاصل ڪيل ڊيٽا.
    درخواستون
  3. Look up the UPS data represented by the corresponding address bit in the provided register address file.

دستاويز / وسيلا

ميگا ٽيڪ نيٽ 485-وائي ايٿرنيٽ ڊيوائس سرور [pdf] هدايت نامو
Net485, Net485-Y, MegaTec 2023-7-6, Net485-Y Ethernet Device Server, Net485-Y, Ethernet Device Server, Device Server

حوالو

تبصرو ڇڏي ڏيو

توهان جو اي ميل پتو شايع نه ڪيو ويندو. گهربل فيلڊ نشان لڳل آهن *