scs-sentinel AAA0037 CodeAccess RFID Keypad

SAFETY INSTRUCTIONS
- This manual is an integral part of your product.
- These instructions are provided for your safety. Read this manual carefully before installing and keep it in a safe place for future reference. Select a suitable location.
- Make sure you can easily insert screws and wallplugs into the wall.
- Do not connect your electrical appliance until your equipment is installed and controlled.
- The installation, electric connections, and settings must be made using best practices by a specialized and qualified person.
- The power supply must be installed in a dry place. Check the product is only used for its intended purpose.
DESCRIPTION
Content/ Dimensions
WIRING/ INSTALLING
Installing
Wiring diagram
You don’t need a transformer if your automation is an SGS Sentinel.
To strike/electric lock
To gate automation
D· TO RESET TO FACTORY DEFAULT
- a. Disconnect power from the unit
- b. Press and hold the # key whilst powering the unit back up
- c. On hearing two “Di” release# key, the system is now back to factory settings
- Please note only installer data is restored, user data will not be affected.
INDICATIONS
| Operation Status | Red Light | Green Light | Yellow light | Buzzer |
| Open the door | Bright | DI | ||
| Stand by | Bright | |||
| Press keypad | DI | |||
| Operation successful | Bright | DI | ||
| Operation failed | DI DI DI | |||
| Enter into programming mode | Bright | |||
| In the programming mode | Bright | DI | ||
| Exit from the programming mode | Bright | DI |
USING
F1- Fast programming
Programming a code 
Programming a badge
Door opening
Trigger the opening through the user code
To trigger the opening with a badge, you only have to present the badge in front of the keypad.
Detailed Programming Guide User Settings
| To enter the programming mode Master code 999999 is the default factory master code |
|
| To exit from the programming mode | |
| Note that to undertake the following programming the master user must be logged in | |
| Setting the working mode: Set valid card only users Set valid card and PIN users Set valid card or PIN users | BO Entry is by card only
B1 Entry is by card and PIN together Be# Entry is by either card or PIN Idefault) |
| To add a user in either card or PIN mode, i.e. in the 3 2 mode.
IDefault setting) |
|
| To add a PIN user | 1 User ID number PIN# The ID number is any
number between 1 & 100. The PIN is any four digits between 0000 & 9999 except 1234 which is reserved. Users can be added continuously without exiting the programming mode as follows: User ID no 1 PIN User ID no 2 PIN |
| To delete a PIN user | 2 User ID number Users can be deleted conti nuously without exiting programming mode |
| To change the PIN of a PIN user! This step must be done out of programming mode) | ‘IDnumber# Old P New”00
New PIN# |
| To add a card user ! Method 1) This is the fastest way to enter cards and user ID number auto-generation. | 1 Read card W Cards can be added continuously without exiting programming mode |
| To add a card user ! Method 2) This is the alternative way to enter cards using user ID Allocation. In this method, a user ID is allocated to a card. Only one user ID can be allocated to a single card. | 1 ID number Read card User can be added continuously without exiting the programming mode |
| To delete a card user by card. Note users can be deleted continuously without exiting the programming mode | |
| To delete a card user by user ID. This option can be used when a user has lost their card | |
| To add a card and PIN user in card and PIN mode I 31 | |
| To Add a card and Pin user!The PIN is any four digits between 0000 & 9999 except for 1234 which is reserved.) | Add the card as a card user Press to exit from the programming mode Then allocate the card a PIN as follows: Read card 1234 PIN# PIN# |
| To change a PIN in card and PIN mode IMethod 1) Note that this is done outside programming mode so the user can undertake this themselves | 11 Read Card OldPIN# New PIN#. New PIN# |
| To change a PIN in card and PIN mode ! Method 2) Note that this is done outside programming mode so the user can undertake this themselves | • 10 uniliteral Old PIN New PIN# New PIN# |
| To delete a Card and PIN user just deletes the card | User ID#. |
| To add and delete a card user in card mode 10 0 #. I | |
| To Add and Delete a card user | The operation is the same as adding and deleting a card user in 3 2W |
| TO DELETE ALL USERS | |
| To delete all users. Note that this is 2 0000 # a dangerous option so use it with care | 0000 |
| TO UNLOCK THE DOOR | |
| For a PIN | user Enter the PIN then press |
| For a card User | Read card |
| For a card and PIN user | Read the card then enter PIN# |
Door settings
| RELAY OUTPUT DELAY TIME | |
| To set door relay strike time | Master code # 4 0~99 # * 0-99 is to set the door relative time 0-99 seconds |
Changing the master code
| Changing the master code | 0 New code New code
The master code consists of 6 to 8 digits |
For security reasons, we recommend changing the master code from default.
TECHNICAL FEATURES
- Voltage 12V DC +/-10%
- Badge reading distance 3-6 cm
- Active current< 60mA
- Stand-by current 25±5mA
- Lock load output 3A max
- Operating temperature -45°C – 60°C
- Degree of humidity: 10% – 90% RH
- Relay output delay time
- Possible wiring connections: electric lock, gate automation, exit button
- Backlight keys
- 2000 users, supports badge, PIN, badge+ PIN
- Full programming from the keypad
- Can be used as a stand-alone keypad
- The keyboard can be used to remove the lost badge number, thoroughly eliminate the hidden safety trouble
- Adjustable Door Output time, Alarm time, Door Open time
- Fast operating speed
- Lock output current short circuit protection
- Indicator light and buzzer
- Frequency: 125kHz
- Maximum transmitted power: <20mW
- Protection rating: IP68
Online assistance
Any question?
- For an individual answer, use our online chat on our website www.scs-sentinel.com
H·WARRANTY
- The invoice will be required as proof of purchase date. Please keep it during the warranty period.
- Carefully keep the barcode and the proof of purchase, which will be necessary to claim a warranty.
I-WARNINGS
- Keep matches, candles, and flames away from the device.
- Product functionality can be influenced by strong electromagnetic interference.
- This equipment is intended for private consumer use only.
- Connect all the parts before switching on the power.
- Do not cause any impact on the elements as their electronics are fragile.
- When installing the product, keep the packaging out of reach of children and animals. It is a source of potential danger.
- This appliance is not a toy. It is not designed to be used by children.
- Disconnect the appliance from the main power supply before service.
- Do not clean the product with solvent, abrasive, or corrosive substances.
- Only use a soft cloth. Do not spray anything on the appliance.
- Make sure that your appliance is properly maintained and regularly checked to detect any sign of wear.
- Do not use it if a repair or adjustment is needed. Always call on qualified personnel.
- Don’t throw batteries or out-of-order products with the household waste (garbage).
- The dangerous substances that they are likely to include may harm health or the environment.
- Make your retailer take back these products or use the selective collection of garbage proposed by your city.
- Direct current IP68: Fully protected against dust+ protected against the effects of prolonged immersion (at least one hour at one-meter depth)
- Toutes les infos sure: www.scs-sentinel.com.

- sentinel 110 rue Pierre-Gilles de Gennes 49300 Chol et (France)
Documents / Resources
![]() |
scs-sentinel AAA0037 CodeAccess RFID Keypad [pdf] User Guide AAA0037 CodeAccess RFID Keypad, AAA0037, CodeAccess RFID Keypad, RFID Keypad, Keypad |