SCS Sentinel CodeAccess RFID Keypad

Installation and User Manual

Product Overview

The SCS Sentinel CodeAccess RFID is an access control keypad designed for use with RFID badges. It offers secure and convenient access management for various applications.

Safety Instructions

This manual is an integral part of your product. These instructions are provided for your safety. Read this manual carefully before installing and keep it in a safe place for future reference. Select a suitable location. Make sure you can easily insert screws and wallplugs into the wall. Do not connect your electrical appliance until your equipment is totally installed and controlled. The installation, electric connections and settings must be made using best practices by a specialized and qualified person. The power supply must be installed in a dry place. Check the product is only used for its intended purpose.

Warnings:

Maintenance: Disconnect the appliance from the main power supply before service. Do not clean the product with solvent, abrasive or corrosive substances. Only use a soft cloth. Do not spray anything on the appliance. Make sure that your appliance is properly maintained and regularly checked in order to detect any sign of wear. Do not use it if a repair or adjustment is needed. Always call on qualified personnel.

Disposal: Don't throw batteries or out-of-order products with household waste. Dangerous substances they may contain can harm health and the environment. Make your retailer take back these products or use the selective collection of garbage proposed by your city.

IP68 Rating: Fully protected against dust and protected against the effects of prolonged immersion (at least one hour at one meter depth).

Description

Content / Dimensions

The kit includes:

Wiring / Installation

Installation

The keypad should be mounted securely on a wall. For a better seal, apply silicone to the top and the two sides of the keypad.

Wiring Diagram

Note: A transformer is not required if your automation system is from SCS Sentinel.

To strike/electric lock:

Power Supply: 12V DC

To gate automation: (Similar wiring as above, with specific connections for gate automation)

Reset to Factory Default

  1. Disconnect power from the unit.
  2. Press and hold the '#' key while powering the unit back up.
  3. Upon hearing two “Di” sounds, release the '#' key. The system is now reset to factory settings.

Note: Only installer data is restored; user data will not be affected.

Indications

Operation Status Red Light Green Light Yellow Light Buzzer
Open the door Bright BIP
Stand by Bright
Press keypad Bright BIP
Operation successful Bright BIP BIP BIP
Operation failed BIP BIP BIP
Enter into programming mode Bright BIP
In the programming mode Bright BIP
Exit from the programming mode Bright BIP

Using the Keypad

Fast Programming

Programming a code:

Enter programming mode (default master code: 999999) *999999#, then add a code: 1#. To add a user code (1-100), enter user number, then user code (4 digits, not 1234), then confirm: [User Number]#[User Code]##. Exit programming mode: **.

Programming a badge:

Enter programming mode (default master code: 999999) *999999#, then add a badge: 1#. Present the badge to the keypad. Exit programming mode: **.

Door opening:

By user code: Enter the programmed user code and press '#'.

By badge: Present the programmed badge to the keypad.

Detailed Programming Guide

User Settings

To enter programming mode: *Master code# (default is 999999).

To exit programming mode: *.

Setting the working mode:

Adding a user (Mode 32#):

Adding/Deleting Card Users:

Adding/Deleting Card and PIN Users (Mode 31#):

Adding/Deleting Card Users (Mode 30#):

Operations are the same as for Mode 32#.

Delete all users:

2 0000 #. Use with caution.

Unlock the door:

Door Settings

Relay Output Delay Time

To set door relay strike time: * Master code # 4 [0-99] # *. 0-99 corresponds to the delay time in seconds.

Changing the Master Code

To change the master code: 0 [New code] # [New code] #. The master code consists of 6 to 8 digits.

It is recommended to change the master code from the default for security reasons.

Technical Features

Assistance Technique

For assistance, contact the technical support at 0 892 350 490 (Service 0,15 € / min + call charges). For service hours and more information, visit www.scs-sentinel.com.

Before contacting support, please have the product reference number ready. It is also recommended to test the product by connecting it "flying leads" on a table to determine if the issue is with the material or the installation.

Warranty

Warranty: 2 years. The invoice will be required as proof of purchase date. Keep the barcode and proof of purchase for warranty claims.

Models: AAA0037 CodeAccess RFID Keypad, AAA0037, CodeAccess RFID Keypad, RFID Keypad, Keypad

PDF preview unavailable. Download the PDF instead.

teclado de acceso rfid con placas de proximidad codeaccess rfid-manual-6833 fr.1713442810912 ?SID scssentinel=sdkq383u55qavuj Adobe InDesign 19.0 (Windows) Adobe PDF Library 17.0

Related Documents

Preview SCS Sentinel CodeAccess RFID Clavier de Codage avec Badges - Manuel d'Utilisation et d'Installation
Manuel d'utilisation et d'installation pour le clavier SCS Sentinel CodeAccess RFID, détaillant les fonctionnalités, le câblage, la programmation et les spécifications techniques.
Preview SCS Sentinel : Offre Clavier de Codage Gratuit avec Motorisation OpenGate
Découvrez l'offre promotionnelle SCS Sentinel : recevez un clavier de codage CodeAccess A gratuit pour tout achat d'une motorisation de portail OpenGate. Détails sur l'éligibilité, la procédure et les conditions.
Preview SCS Sentinel CodeGate Wireless Keypad Installation and Programming Guide
A comprehensive guide to installing and programming the SCS Sentinel CodeGate wireless keypad for gate automation, covering setup, code changes, and troubleshooting in multiple languages.
Preview SCS Sentinel OpenGate 2 & VisioDoor 7+RFID: Installation and User Manual
Comprehensive guide for SCS Sentinel's OpenGate 2 articulated arm gate automation system and VisioDoor 7+RFID video intercom system, covering installation, setup, features, maintenance, and troubleshooting.
Preview SCS Sentinel CodeAccess A Keypad User Manual
This manual provides instructions for the SCS Sentinel CodeAccess A keypad, covering installation, wiring, programming, usage, technical specifications, warranty, and safety warnings. It details how to program access codes and badges, manage users, and configure door settings.
Preview SCS Sentinel CodeAccess A Keypad Installation and User Manual
Comprehensive guide for the SCS Sentinel CodeAccess A keypad, covering installation, wiring, programming, technical specifications, and safety warnings. Learn how to program codes, badges, and manage user access.
Preview SCS Sentinel OutCam ROTATIVE: Guía de Usuario y Configuración
Manual completo para la cámara de vigilancia exterior rotativa SCS Sentinel OutCam ROTATIVE. Aprenda a instalar, configurar y usar la aplicación iSCS Sentinel para monitoreo remoto, detección de movimiento y más.
Preview Guide de Réparabilité CarGate 800 TRIO
Guide détaillé pour la réparabilité du système d'automatisme de portail SCS Sentinel CarGate 800 TRIO (MGA0011), incluant le remplacement des composants clés comme le moteur, la carte mère, le transformateur et le chariot de guidage.