Product Overview
The SCS Sentinel CodeAccess RFID is an access control keypad designed for use with RFID badges. It offers secure and convenient access management for various applications.
Safety Instructions
This manual is an integral part of your product. These instructions are provided for your safety. Read this manual carefully before installing and keep it in a safe place for future reference. Select a suitable location. Make sure you can easily insert screws and wallplugs into the wall. Do not connect your electrical appliance until your equipment is totally installed and controlled. The installation, electric connections and settings must be made using best practices by a specialized and qualified person. The power supply must be installed in a dry place. Check the product is only used for its intended purpose.
Warnings:
- Keep matches, candles and flames away from the device.
- Product functionality can be influenced by strong electromagnetic interference.
- This equipment is intended for private consumer use only.
- Connect all the parts before switching on the power.
- Do not cause any impact on the elements as their electronics are fragile.
- When installing the product, keep the packaging out of reach of children and animals. It is a source of potential danger.
- This appliance is not a toy. It is not designed to be used by children.
Maintenance: Disconnect the appliance from the main power supply before service. Do not clean the product with solvent, abrasive or corrosive substances. Only use a soft cloth. Do not spray anything on the appliance. Make sure that your appliance is properly maintained and regularly checked in order to detect any sign of wear. Do not use it if a repair or adjustment is needed. Always call on qualified personnel.
Disposal: Don't throw batteries or out-of-order products with household waste. Dangerous substances they may contain can harm health and the environment. Make your retailer take back these products or use the selective collection of garbage proposed by your city.
IP68 Rating: Fully protected against dust and protected against the effects of prolonged immersion (at least one hour at one meter depth).
Description
Content / Dimensions
The kit includes:
- 1 x CodeAccess RFID Keypad (Dimensions: 13 cm height, 5.1 cm width, 2.3 cm depth)
- 5 x RFID Badges
- 1 x Manual
- Screws + Anti-vandal key
Wiring / Installation
Installation
The keypad should be mounted securely on a wall. For a better seal, apply silicone to the top and the two sides of the keypad.
Wiring Diagram
Note: A transformer is not required if your automation system is from SCS Sentinel.
To strike/electric lock:
- ROSE (x2): NOT USED
- GREEN: NOT USED
- WHITE: NOT USED
- YELLOW: EXIT BUTTON
- RED: +12V
- BLACK: STRIKE/ELECTRIC LOCK
- BLUE: COM
- PURPLE: NOT USED
- ORANGE: NOT USED
Power Supply: 12V DC
To gate automation: (Similar wiring as above, with specific connections for gate automation)
Reset to Factory Default
- Disconnect power from the unit.
- Press and hold the '#' key while powering the unit back up.
- Upon hearing two “Di” sounds, release the '#' key. The system is now reset to factory settings.
Note: Only installer data is restored; user data will not be affected.
Indications
Operation Status | Red Light | Green Light | Yellow Light | Buzzer |
---|---|---|---|---|
Open the door | Bright | BIP | ||
Stand by | Bright | |||
Press keypad | Bright | BIP | ||
Operation successful | Bright | BIP BIP BIP | ||
Operation failed | BIP BIP BIP | |||
Enter into programming mode | Bright | BIP | ||
In the programming mode | Bright | BIP | ||
Exit from the programming mode | Bright | BIP |
Using the Keypad
Fast Programming
Programming a code:
Enter programming mode (default master code: 999999) *999999#
, then add a code: 1#
. To add a user code (1-100), enter user number, then user code (4 digits, not 1234), then confirm: [User Number]#[User Code]##
. Exit programming mode: **
.
Programming a badge:
Enter programming mode (default master code: 999999) *999999#
, then add a badge: 1#
. Present the badge to the keypad. Exit programming mode: **
.
Door opening:
By user code: Enter the programmed user code and press '#'.
By badge: Present the programmed badge to the keypad.
Detailed Programming Guide
User Settings
To enter programming mode: *Master code#
(default is 999999).
To exit programming mode: *
.
Setting the working mode:
- Mode 30#: Entry by card only.
- Mode 31#: Entry by card and PIN together.
- Mode 32#: Entry by either card or PIN (default).
Adding a user (Mode 32#):
- Add PIN user:
1 [User ID number] # [PIN] #
. Users can be added continuously. - Delete PIN user:
2 [User ID number] #
. Users can be deleted continuously. - Change PIN:
* [ID number] # [Old PIN] # [New PIN] # [New PIN] #
. This is done outside programming mode.
Adding/Deleting Card Users:
- Method 1 (Fast):
1 Read card #
. Cards can be added continuously without exiting programming mode. - Method 2 (User ID Allocation):
1 [ID number] # Read card #
. User can be added continuously without exiting programming mode. - Delete card user by card:
2 Read Card #
. - Delete card user by ID:
2 User ID #
.
Adding/Deleting Card and PIN Users (Mode 31#):
- Add Card and PIN user: Add card as for a card user, press '*' to exit programming mode. Then allocate PIN:
* Read card [1234] # [PIN] # [PIN] #
. - Change PIN in Card and PIN mode (Method 1):
* Read Card [Old PIN] # [New PIN] # [New PIN] #
. - Change PIN in Card and PIN mode (Method 2):
* [ID number] # [Old PIN] # [New PIN] # [New PIN] #
. - Delete Card and PIN user: Delete the card.
Adding/Deleting Card Users (Mode 30#):
Operations are the same as for Mode 32#.
Delete all users:
2 0000 #
. Use with caution.
Unlock the door:
- For a PIN: Enter the PIN then press '#'.
- For a card user: Read card.
- For a card and PIN user: Read card then enter PIN '#'.
Door Settings
Relay Output Delay Time
To set door relay strike time: * Master code # 4 [0-99] # *
. 0-99 corresponds to the delay time in seconds.
Changing the Master Code
To change the master code: 0 [New code] # [New code] #
. The master code consists of 6 to 8 digits.
It is recommended to change the master code from the default for security reasons.
Technical Features
- Voltage: 12V DC +/-10%
- Badge reading distance: 3-6 cm
- Active current: < 60mA
- Stand-by current: 25±5mA
- Lock load output: 3A max
- Operating temperature: -45°C ~ 60°C
- Degree of humidity: 10% - 90% RH
- Relay output delay time adjustable
- Possible wiring connections: electric lock, gate automation, exit button
- Backlight keys
- 2000 users, supports badge, PIN, badge + PIN
- Full programming from the keypad
- Can be used as a standalone keypad
- The keyboard can be used to remove lost badge numbers, addressing safety concerns.
- Adjustable Door Output time, Alarm time, Door Open time
- Fast operating speed
- Lock output current short circuit protection
- Indicator light and buzzer
- Frequency: 125kHz
- Maximum transmitted power: <20mW
- Protection rating: IP68
Assistance Technique
For assistance, contact the technical support at 0 892 350 490 (Service 0,15 € / min + call charges). For service hours and more information, visit www.scs-sentinel.com.
Before contacting support, please have the product reference number ready. It is also recommended to test the product by connecting it "flying leads" on a table to determine if the issue is with the material or the installation.
Warranty
Warranty: 2 years. The invoice will be required as proof of purchase date. Keep the barcode and proof of purchase for warranty claims.