The Santa Fe Ultra98/120 are ventilating dehumidifiers that integrate into the heating and cooling system to provide the ultimate in comfort, health,, and property protection through:

  • + Dehumidification
  • + Optional Outdoor Air Ventilation
  • + Air Filtration

SAFETY INSTRUCTIONS

WARNING!

THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN SERIOUS INJURY OR DEATH.

CAUTION!

  • THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN INJURY OR MATERIAL PROPERTY DAMAGE.
  • Read the installation, operate,,on and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from the Santa Fe Whole House Ventilating Dehumidifier.

WARNING!

120 VOLTS MAY CAUSE SERIOUS INJURY FROM ELECTRIC SHOCK. DISCONNECT ELECTRICAL POWER BEFORE STARTING INSTALLATION OR SERVICING, AND LEAVE POWER DISCONNECTED UNTIL INSTALLATION OR SERVICE IS COMPLETED.

CAUTION!

  • READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.
  • ALWAYS USE CAUTION AND WEAR CUT-RESISTANT GLOVES WHEN HANDLING SHEET METAL.
  • IMPROPER INSTALLATION MAY CAUSE PROPERTY DAMAGE OR INJURY.
  • INSTALLATION, SERVICE, AND MAINTENANCE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN.
  • THE DEHUMIDIFIER IS HEAVY. HANDLE WITH CARE AND FOLLOW INSTALLATION INSTRUCTIONS.
  • NEVER OPERATE A UNIT WITH A DAMAGED POWER CORD. IF THE POWER CORD IS
  • DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT, OR A SIMILARLY QUALIFIED PERSON TO AVOID A HAZARD.
  • THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY,, OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE  OR KNOWLEDGEUNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR
  • SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.

ASSEMBLY & INSTALLATION

  1.  Unpack Box.
  2.  Check that you have all pathe rts:
    •  Dehumidifier (1)Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-1
    •  Leveling feet (4)Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-2
    •  Filter – 1.75”x14”x17.5” MERV 13 (1)Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-3
    •  10” Round Duct Collars (2)Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-4
    •  6” Round Duct Collar (1)Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-28

 Register warranty at santa-fe-products.com

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-5

Read all remaining steps and warnings before continuing. 

DEHUMIDIFIER SET UP

 Important Precautions

  • The device is designed to be installed indoors in a space that is protected from rain and flooding.
  • Install the unit with enough space to access all sides for maintenance and service. The entire shell needs to be removed intoo repairs.
  • Avoid directing the discharge of air at people. The dehumidifier should be used in the upright position.
  • If used near a water source; be certain there is no chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet.
  • DO NOT use the dehumidifier as a bench or table.
  • Do not place the dehumidifier directly on structural building members without vibration absorbers or unwanted noise may result. Place the Santa Fe Ultra98/120 on supports to raise the base of the unit.
  • A drain pan with a float switch must be placed under the dehumidifier if installed above a living area or above an area where water leakage could cause damage.

DEHUMIDIFIER SET UP

Location Considerations

  • Allow sufficient clearance to handle the unit’s overall dimensions as well as the necessary return and supply ductwork to the unit.
  • Allow sufficient clearance for filter removal and to prevent airflow obstruction.
  • Electrical service access will require the removal of the outside shell. Allow sufficient clearance around the unit.
  • Locate the dehumidifier in an area where the unit’s 9 ft. cord can easily reach the electrical outlet.
  • Locate the dehumidifier in an area where field wiring the control (low voltage) to the unit will be possible.
  • A back draft damper is required in the supply duct of the Santa Fe Ultra98/120, especially when connecting to the supply ducting system. The backdraft damper prevents supply air from counter-flowing through the Santa Fe Ultra98/120 when it is not operating. The dehumidifier’s location should be chosen to allow  installation of this accessory if necessary.
  • The Santa Fe Ultra98/120 may be suspended with the hang kit or a suitable alternative from structural members, ensuring the assembly supports the dehumidifier’s base in its entirety. Do not hang the Santa Fe Ultra98/120 from its’ cabinet.
  • Allow for proper drainage and routing of needed drain pipes.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-6

CAUTION!

REMOVE COMPRESSOR SHIPPING TIE FROM THE UNIT. FAILURE TO REMOVE THE SHIPPING TIE WILL CAUSE EXCESS VIBRATION TO BE TRANSMITTED TO THE FRAME.

Removal of Compressor Shipping Support

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-7

  • The Santa Fe Ultra98/120 uses a compressor to power the refrigeration system. To protect the compressor and refrigeration system during shipping, a plastic tie wrap secures it to the unit’s frame. Remove the tie wrap by cutting the tie wrap and pulling from the unit as shown. After removing tie wrap, insert plastic plugs provided into the holes.

ATTACHING DUCT COLLARS

  1. Outdoor Air Ventilation Duct
    • Outdoor air ventilation is optional. If setting up the unit to provide outdoor air ventilation, see page 18.
  2. Return Air Inlet
    • A 10” diameter duct collar is attached to the unit.
  3.  Supply Air Outlet
    • The back panel of the dehumidifier can be rotated to allow for horizontal flow through or vertical flow through of the supply air.
    •  Horizontal Flow Through The unit ships configured for a horizontal flow through. A 10” diameter duct collar is attached to the unit.
    •  Vertical Flow Through Remove the exhaust panel using a T25 torx bit. Rotate the panel so the exhaust collar is located on the top of the unit. Align screw holes and snap the panel onto the base. Secure the exhaust panel to the base by replacing the six screws.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-8

ELECTRICAL REQUIREMENTS

The Santa Fe Ultra98/120 plugs into a common grounded 115VAC outlet. Locate the dehumidifier in an area where the unit’s 9 ft. cord can easily reach a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area that may become wet, a GFCI protected circuit is recommended. Consult local electrical codes for any further information. Santa Fe offers a variety of control devices for use with the Santa Fe Ultra98/120. The controls are to be located remotely from the dehumidifier and placed in the space to be conditioned. Low voltage (24 Volt) controls can be used with the Santa Fe Ultra98/120 and MUST be connected with low voltage (18-22 gauge) thermostat wire.

WARNING!

THE REMOTE CONTROLS OF THE SANTA FE ULTRA98/120 ARE POWERED BY A LOW VOLTAGE CIRCUIT (24VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.

CAUTION!

DO NOT ALLOW THE 24V TERMINAL TO CONTACT THE COM/DMPR TERMINALS ON THE SANTA FE ULTRA98/120 OR DAMAGE TO THE TRANSFORMER WILL RESULT.

CAUTION!

SOME OF THE SCREWS TERMINALS ON THE SANTA FE ULTRA98/120 MAY NOT BE USED WITH CERTAIN CONTROLS AND SHOULD BE LEFT UNCONNECTED.

Electrical Precautions

  • Do not install the control where it may not accurately sense the relative humidity such as near HVAC supply registers, near exterior doors, on an outside wall, near a window, or near a water source.
  • The screw terminals on the Santa Fe Ultra98/120 and the control are labeled to prevent confusion.
  • Be sure to consult the electrical schematic in the CONTROLS Section (pages 20-21) of this manual or inside the access panel of the Santa Fe Ultra98/120 before making control connections.

ELECTRICAL REQUIREMENTS

Wiring Schematics

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-9

DRAIN INSTALLATION

The Santa Fe Ultra98/120 generate condensate.
Place a secondary drain pan with a float switch under the dehumidifier if it is suspended above a finished area or in an area where water leakage could cause damage. A drain trap is required for the dehumidifier to run properly (see diagram below). Install a 3/4″ threaded male NPT adapter to the drain pan. Install a drain pipe assembly utilizing 3/4″ PVC pipe to transport the condensate to a drain. Pitch of drain should be 1″ per 10′. An optional condensate pump kit is available for use with the Santa Fe Ultra98/120 and may be installed if lift is required to dispose of condensate. Condensate is automatically pumped to a remote location when the water level in the pump’s reservoir rises to close the float switch. The pump also contains a safety float switch. The white leads from this switch extend from beneath the pump cover. This switch should be installed in series with the field wire that connects to the common lead from the Santa Fe Ultra98/120 to the control panel. If the pump fails, this switch opens the common control circuit and stops water production before the reservoir overflows. Contact a qualified electrician to install the safety float switch to the Santa Fe Ultra98/120 dehumidifier.

Drain Installation

  • Dehumidifiers commonly use a negative air pressure drain pan. This causes air to flow backwards thru the drain system which can cause water to pool inside the dehumidifier and leak. A drain trap prevents this issue by trapping water in the pipe to stop air from flowing backwards.
  • Please see the trap diagram below. This assembly can be made with common ¾” PVC pipe fittings. The pipe
  • measurements and placement of the cap and vent are critical to the function of the trap. Once trap is assembled, be sure to fill with water.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-9

DUCTING TO HVAC SYSTEMS

CAUTION!

DO NOT CONNECT WITH A STATIC PRESSURE GREATER THAN OR EQUAL TO +0.5 WG. CONTACT TECHNICAL SUPPORT AT 800-533-7533 FOR ADDITIONAL DETAILS.

Ducting Considerations:

  • All flexible ducting connected to the Santa Fe Ultra98/120 should be UL listed.
  • A short piece of flexible ducting on all Santa Fe Ultra98/120 duct connections is recommended to reduce noise and vibration transmitted to rigid ductwork in the structure.
  • Use a minimum 10″ diameter round or equivalent rectangular duct for total duct lengths of up to 25′. Use a minimum 12″ diameter or equivalent for longer lengths.
  • Grills or diffusers on the duct ends must not excessively restrict airflow.
  • A length of 8″ or more of insulated flex duct or any other vibration isolating material on the outlet of the Santa Fe Ultra98/120 will reduce air noise from the blower.
  • Effective dehumidification may require that ducting be branched to isolated, stagnant air flow areas. When ducting to two or three areas, use 8″ or larger diameter branch ducting. When ducting to four or more areas, use 6″ or larger diameter branch ducting. Provisions must be made to provide airflow from supply locations to the central return location. Proper air distribution is important to ensure even humid-ity control and heat distribution throughout the structure.
  • DO NOT locate the return in a bathroom or a kitchen.

Decide Where To Place The Unit.
CAUTION! ALLOW FOR ENOUGH SPACING TO PROPERLY ROUTE THE RETURN AND SUP-PLY CONNECTION

Choose Weather To Place On Floor Or Hang Dehumidifier.
CAUTION! INTERNAL STOPS LIMIT FEET HEIGHT. DO NOT TIGHTEN FEET BEYOND THE RESISTANCE PROVIDED BY STOPS.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-11

DUCTING TO HVAC SYSTEMS

  1.  Recommended HVAC System Installations

 Attic

The recommended installation draws air from a central location through a dedicated return to the dehumidifier and ducts the supply of the dehumidifier to the air supply of the HVAC system. Utilize the optional outdoor air ventilation duct to provide outdoor air.

  • Install a dedicated 10″ air return for the Santa Fe Ultra98/120 from a central area of the structure.
  • Duct the supply of the Santa Fe Ultra98/120 to the supply of the HVAC system with a backdraft damper.
  • If the existing system has multiple returns, instead of installing a dedicated return to the Santa Fe Ultra98/120, it is possible to select one to disconnect from the existing HVAC system and use it for the dedicated Santa Fe Ultra98/120 return. Select a return from a central location in the house that is always open to the rest of  the structure. DO NOT use a return from a room where doors are kept closed.
  • DO NOT locate return in a bathroom or kitchen.
  • Control should be located remotely from the dehumidifier and placed in a central location.

Dedicated Santa Fe Return to HVAC Supply

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-12

 Installation in a Basement or Crawlspace

Install a separate 8″ return for the Ultra98/120 in a central area of the structure. Duct the supply of the dehumidifier to the air supply of the HVAC system with a backdraft damper.

Optional: Duct the supply of the Ultra98/120 to a 8″ x 8″ x 8″ tee/damper with a gravity draft damper, adjusted to 20% open to the basement. CAUTION: Air takes the path of least resistance. If the upper levels of the living space are not receiving the appropriate amount of dry air, this damper may need to be adjusted. When the dehumidifier is not running, there is a chance that air from the basement or crawlspace will make its way back through the gravity damper and into the living space.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-13

Alternative HVAC System Installation
If the Recommended Dedicated Ultra Series Return to HVAC Supply Installation is not possible, there are several alternative installation options available.

  •  DO NOT locate return in a bathroom or kitchen.
  • Control should be located remotely from the dehumidifier and placed in a central location.
  • For basement and crawl space installations, an optional tee can be installed on the Ultra Series Supply.

 HVAC Return to HVAC Supply

  • Check Damper should be in place between the Return and Supply connections of the dehumidifier.
  • If Check Damper is not in place, the HVAC fan must turn on when the dehumidifier is in operation.
  • If the system has greater than 0.5” WG the ducting must be reconfigured.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-14

HVAC Supply to HVAC Supply

CAUTION!

TO AVOID THE DEHUMIDIFIER CYCLING IN AND OUT OF DEFROST, IT IS RECOMMENDED THAT THE LEAVING AIR TEMPERATURE OF THE A/C COIL IS NOT BELOW 55°F. ALSO, THIS INSTALL IS NOT RECOMMENDED FOR CLIMATES WERE THE HEATING SYSTEM WILL RUN DURING THE SPRING AND FALL TIMES OF THE YEAR, AS THIS COULD DIMINISH THE WATER REMOVAL CAPABILITY OF THE DEHUMIDIFIER.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-15

If Check Damper is not in place, the HVAC fan must turn on when the dehumidifier is in operation

 WARNING

DUE TO PRESSURE RESISTANCE IT IS NOT RECOMMENDED TO USE THE OPTIONAL OUTDOOR AIR INTAKE WHEN INSTALLING THE DEHUMIDIFIER SUPPLY TO SUPPLY.

CAUTION!

PLEASE NOTE:

RETURN TO RETURN INSTALLS ARE TO BE CONSIDERED LAST RESORT OPTIONS AND ARE NOT RECOMMENDED. THE DEHUMIDIFIER WILL HEAT THE AC COOLING COILS WHICH DIMINISHES THE AMOUNT OF WATER THE AC SYSTEM WILL REMOVE WHEN OPERATING. IF THIS INSTALLATION IS CHOSEN, THE DEHUMIDIFIER MUST ACTIVATE THE HVAC BLOWER AND AC CALLS NEED TO LOCK OUT THE DEHUMIDIFIER FROM RUNNING. PLEASE CHECK YOUR LOCAL CODES PRIOR TO INSTALLING.

 Dedicated Ultra Series Return to HVAC Return

  • Create a separate return for the Ultra Series Dehumidifier in a central area of the building.Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-16
  • Installing the supply air from the Ultra Series Dehumidifier to the return of the HVAC system requires the HVAC fan to run when the Ultra Series Dehumidifier is operating.Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-17

HVAC Return to HVAC Return
If Check Damper is not in place, the HVAC fan must turn on when the dehumidifier is in operation.

No Existing Ductwork Installation

  • When installing the Ultra Series Dehumidifier in a structure that does not have a forced-air HVAC system, a single return for the dehumidifier should be installed in a central location.
  • Install an insulated duct from outside to the 6” collar of the Ultra Series Dehumidifier to provide outdoor air ventilation (optional).
  • The supply of the Ultra Series Dehumidifier should be ducted to the rooms in the home that have the ductless mini-split heads and as close to the heads as possible. Be sure to utilize multiple rooms to allow air inside the structure to properly circulate. Proper air distribution is important to ensure even humidity control and  heat distribution throughout the structure.
  • A 6” diameter duct is recommended for branches to bedrooms. An 8” diameter duct is recommended for branches to larger areas.
  • DO NOT locate return in a bathroom or kitchen.
  • DO NOT locate the supply in rooms where doors may be closed.
  • Control should be located remotely from the dehumidifier and placed in a central location.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-18

DUCTING TO HVAC SYSTEMS (Closet Installations)

WARNING!

WHEN INSTALLING THE DEHUMIDIFIER AS PART OF A COMBUSTION TYPE HVAC SYSTEM (GAS, OIL, PROPANE, ETC.), FOLLOW ALL LOCAL AND NATIONAL BUILDING AND SAFETY CODES.

Recommended Closet Installation
Due to space limitations, a closet installation may require additional considerations. Locate the dehumidifier under or next to the HVAC system as space allows. A passive vent or louver door is required to allow air to be pulled in from the living space.

  • No inlet duct is required. Air is pulled through the passive vent or louver door from the living space.
  • Install an insulated duct from outside to the 6” collar of the Ultra Series Dehumidifier to provide outdoor air ventilation (optional).
  • Control should be located remotely from the dehumidifier and placed in a central location.
  • Where outlet space is restricted, the outlet duct collar is optional or vertical flow through may be preferred.

Central Return to HVAC Supply
Duct the supply of the Ultra Series Dehumidifier to the supply of the existing HVAC system with a backdraft damper.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-19

DUCTING TO HVAC SYSTEMS (Closet Installations)

CAUTION!

PLEASE NOTE: RETURN TO RETURN INSTALLS ARE TO BE CONSIDERED LAST RESORT OPTIONS AND ARE NOT RECOMMENDED. THE DEHUMIDIFIER WILL HEAT THE AC COOLING COILS WHICH DIMINISHES THE AMOUNT OF WATER THE AC SYSTEM WILL REMOVE WHEN OPERATING. PLEASE CHECK YOUR LOCAL CODES PRIOR TO INSTALLING.

Alternative Closet Installation
If the Recommended Closet Installation is not possible, there are several alternative installation options available.

  • No inlet duct is required. Air is pulled through the passive vent or louver door from the living space.
  • Install an insulated duct from outside to the 6” collar of the Ultra Series Dehumidifier to provide outdoor air ventilation (optional).
  • Control should be located remotely from the dehumidifier and placed in a central location.

Central Return to HVAC Return
Duct the supply of the Ultra Series Dehumidifier to the return side of the existing HVAC system. In a central return system, the HVAC fan must run when the dehumidifier is running.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-20

No Duct – Central Return to HVAC Return
Attach outlet duct with a vertical flow through so air is not discharged into wall or other obstruction. The HVAC system will naturally pull dehumidifier air from the closet and distribute it throughout the structure.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-21

OUTDOOR AIR VENTILATION

Outdoor air ventilation is optional.
Outdoor air may be brought into the structure by connecting an insulated duct from outside the structure to the 6” inlet of the Santa Fe Ultra98/120. A ventilation control is needed to program the time and frequency that the unit introduces outside air. The time and frequency of ventilation should be based on the size and occupancy of the residence.

  • The outdoor air ventilation duct should be connected to the 6” round collar on the front of the Santa Fe Ultra98/120.
  • An insulated 6” diameter duct can provide up to 75 CFM of outside air.
  • If a motorized damper is not being used, outdoor air is controlled by the manual damper in the 6” collar of the Santa Fe Ultra98/120.
  • Performance of the Santa Fe Ultra98/120 can be impacted by inside and outside air conditions.
  • When a 6” motorized damper is used, a digital control is required.
  • It may be necessary to use 8” duct work if additional outdoor air is required.
  • In cold climates or at times when the dew point is low, ventilation can be used to dehumidify the structure, making the Santa Fe Ultra98/120 capable of year-round drying.

Outdoor Air Ventilation With Dehumidifier Off and Fan Only Operation
Outside air mixes with return air prior to beginning the dehumidification process. Outside and inside temperature and relative humidity will impact the combined outlet air conditions.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-22

OUTDOOR AIR VENTILATION

Determine Ventilation Requirements
The MINIMUM ventilation requirement is calculated using ASHRAE 62.2-2016. Use one or both of the options below to determine your ventilation requirement. Follow all local and national building and safety codes.

Option 1: Calculating Airflow Requirement Using ASHRAE 62.2-2016 Airflow Equation

  • ASHRAE Airflow in CFM = [House Area in Sq.Ft. x 0.03] + [(Number of Bedrooms +1) x 7.5]
  • NOTE: Use ‘Number of Bedrooms + 1’ or ‘Number of Occupants’, whichever is larger.
  • Example 1: Number of Bedrooms + 1 1800 square foot house with 3 bedrooms, 4 occupants = [1800 X 0.03] + [(3+1) X 7.5] = 84 CFM
  • Example 2: Number of Occupants 1800 square foot house with 3 bedrooms, 5 occupants = [1800 X 0.03] + [5 X 7.5] = 91.5 CFM

Record the required CFM ____________

Option 2: Calculating Airflow Requirement Using Table 4.1 from ASHRAE 62.2-2019 Ventilation Air Requirements, CFM

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-23

CONTROLS

A control must be used with the Santa Fe Ultra98/120. Santa Fe offers the DEH 3000 proprietary control. The DEH 3000 allows homeowners to monitor and control relative humidity and proper ventilation levels in their home. This control is also available with a remote sensing option.

NOTE: The DEH 3000 is sold separately. Other thermostats are compatible with the Santa Fe Ultra98/120.

 Wiring Controls

CAUTION!

DO NOT ALLOW THE 24V TERMINAL FROM THE SANTA FE ULTRA98/120 TO CONTACT THE COM TERMINAL ON THE SANTA FE ULTRA98/120 OR DAMAGE TO THE TRANSFORMERS WILL RESULT.

Circuit Breaker
To prevent damage to the 24 volt control transformer, the Santa Fe Ultra98/120 comes with a resettable circuit breaker. Check wiring for any electrical short and repair before resetting breaker. Resetting the circuit breaker without correcting the electrical short may result in transformer damage. Be sure to check the electrical schematic in this manual or inside the access panel of the Santa Fe Ultra98/120 before making any control connections. The reset button for the circuit breaker can be found on the back of the unit.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-24

Control Connections
The control and the Santa Fe Ultra98/120 are labeled to prevent confusion. Depending on the control, some of the screw terminals on the Santa Fe Ultra98/120 may not be used. Be sure to consult the electrical schematic in this manual or inside the access panel of the Santa Fe Ultra98/120 before making control connections.

Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-25

CONTROLS

A low voltage control must be used with the Santa Fe Ultra98/120.

Terminal Block Control Operation

Ultra98
COM 24VAC Power Transformer Neutral Side
FAN Fan Control
24V Transformer High Side
DEHU Dehumidification (Fan and Compressor) Control
DMPR 24VAC Power Transformer Neutral Side
* Spare Terminal (Open)
Ultra120
COM 24VAC Power Transformer Neutral Side
FAN Fan Control
24V Transformer High Side
DEHU Dehumidification (Fan and Compressor) Control
 

Float

External Low Voltage Float Switch or Water Sensor (Use Normally Closed Switch)
Float External Low Voltage Float Switch or Water Sensor (Use Normally Closed Switch)
Between the COM lead and the 24V TERMINAL is a 40VA transformer. This low voltage power source powers the relay coils which control the fan and compressors. This 24VAC transformer can also be used to power HVAC accessories external to the dehumidifier.
Compressor ON/Fan On Make contact between 24V and DEHU terminals
Compressor OFF/Fan On Make contact between 24V and FAN terminals
Power HVAC Accessory Connect the accessory to the DMPR and 24V terminals

NOTE: 18 gauge wire needed between the Santa Fe Ultra98/120 dehumidifier and the external control.

AIR FILTRATION

The Santa Fe Ultra98/120 is equipped with a MERV-13 (Dimensions: 1.75”x14”x17.5”) air filter. The filter should be checked and replaced every three to six months. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency. DO NOT operate the unit without the recommended filter. Filter non-compliance voids the product warranty.

CAUTION!

MAKE SURE UNIT IS OFF BEFORE CHANGING THE FILTER.

Changing the Filter
For greatest filtration and efficiency of the Santa Fe Ultra98/120, it is recommended the air filter be replaced every three to six months with a MERV 13 rated filter.

  • Step 1: Remove the filter door from one side of the Santa Fe Ultra98/120 by pushing the snap button in and gently pulling the door away from the unit. Then pull up to disengage the door from the slot.Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-26
  • Step 2: Remove the filter by gently pulling straight out of the unit. Insert new filter by gently pushing it  straight into the unit. Make sure the AIR FLOW arrow on the filter is pointing into the unit.Santa-Fe-Ultra-Series -Relative-Humidity-Control-fig-27
  • Step 3: Replace filter door ensuring the opening is fully covered.

AIR FILTRATION

 MERV Rating Chart

 

Standard 52.5 Minimum Efficiency Reporting Value

 

Dust Spot

Efficiency

 

Arrestance

 

Typical Controlled Contaminant

 

Typical Applications and Limitations

 

Typical Ail Filter/Cleaner Type

20 n/a n/a < 0.30 pm Particle

Size

Cleanrooms ≥99.999% eff. On 10-20 pm Particles
19 n/a n/a Virus (unattached) Radioactive Materials Particles
18 n/a n/a Carbon Dust Pharmaceutical Man. Particulates
17 n/a n/a All Combustion Smoke Carcinogenic Materials ≥99.97% eff. On 30 pm Particles
16 n/a n/a 0.30-1.0 pm

Particle Size

General Surgery Bag Filter – Nonsupported
15 >95% n/a All Bacteria Hospital Inpatient Care Micro Fine Fiberglass or Synthetic media, 12-36 in. Deep, 6-12 Pockets
14 90-95% >98% Most Tobacco Smoke Smoking Lounges Box Filter – Rigid Style Cartridge
 

13

 

89-90%

 

>98%

Proplet Nuceli

(Sneeze)

Superior Commercial Buildings Filters 6 to 12 in. Deep, May Use Lofted or Paper Media
12 70-75% >95% 1.0-3.0 pm Particle

Size Legionella

Superior Residential Bag Filter – Nonsupported
11 60-65% >95% Humidifier Dust

Lead Dust

Better Commercial Buildings Micro Fine Fiberglass or Synthetic media, 12-36 in. Deep, 6-12 Pockets
10 50-55% >95% Milled Flour Box Filter – Rigid Style Cartridge
 

9

 

40-45%

 

>90%

 

Welding Fumes

Hospital Laboratories Filters 6 to 12 in. Deep, May Use Lofted or Paper Media
 

8

 

30-35%

 

>90%

3.0-10.0 pm

Particle Size

Commercial Buildings Pleated Filters – Disposable, Extended Surface Area, Thick with Cotton-Polyester Blend Media, Cardboard Frame
 

7

 

25-30%

 

>90%

Mold Spores Hair Spray  

Better Residential

Cartridge Filters – Graded Density Viscous Coated Cube or Pocket Filters, Synthetic Media
6 <20% 85-90% Fabric Protector Dusting Aids Throwaway – Disposable Synthetic Panel Filter
5 <20% 80-85% Cement Dust Pudding Mix Paint Booth Inlet
4 <20% 75-80% >10.0 pm Particle

Size Pollen

Minimal Filtration Throwaway – Disposable Synthetic Panel Filter
3 <20% 70-75% Dust Mites Standing Dust Residential Washable – Aluminum Mesh
2 <20% 65-70% Spray Paint Dust
 

1

 

<20%

 

<65%

Textile Fibers Carpet Fibers  

Window A/C Units

Electrostatic – Self Charging Woven Panel Filter

Table Data Source: United States Environmental Protection Agency

SERVICE

Troubleshooting

CAUTION!

TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED HVAC TECHNICIAN.

Symptom Possible Reason Troubleshooting Procedure
 

 

 

Neither fan nor compressor running.

Dehumidification

is being called for.

1.     Dehumidifier unplugged or

no power to outlet.

2.     Humidity control set too high.

3.     Loose connection in internal or control wiring.

4.     Defective compressor relay.

5.     Defective control transformer.

 

WARNING!

ELECTRICAL SHOCK HAZARD:

Electrical power must be present to perform some tests. These tests should be performed by a qualified service person.

Troubleshooting Procedure for Control Related Issues

This method of diagnosis will test the 3 main components of the control circuit individually to indicate any potential problems. This is to be

used when the control will not activate the main unit.

1.     Detach field control wiring connections from

the terminals on the main unit.

2.     Connect the 24V and FAN terminals together; only the fan should run. Disconnect the terminals.

3.     Connect the 24V and DEHU terminals together; fan and compressor should run. Disconnect the terminals.

4.     If this test works, the main unit is working correctly from a control standpoint.

5.     Reconnect field control wiring to the

terminals on the main unit.

6.     Remove the control panel cover and detach the field wiring from the control connections.

7.     Connect the 24V and FAN terminals together; only the fan should run. Disconnect the terminals.

8.     Connect the 24V and DEHU terminals together; fan and compressor should run. Disconnect the terminals.

9.     If this test works, then the field control

wiring is ok.

10.  If the problem persists, then the control is most likely faulty.

 

 

Compressor is not running.

Dehumidification is being called for. Fan is running.

1.     Defective compressor run capacitor.

2.     Loose connection in compressor circuit.

3.     Defective compressor overload.

4.     Defective compressor.

5.     Defrost thermostat open.

 

 

 

 

Compressor cycles on and off.

Dehumidification is

being called for.

1.     Low ambient temperature and/or humidity causing unit to cycle through defrost mode.

2.     Defective compressor overload.

3.     Defective compressor.

4.     Defrost thermostat defective.

5.     Dirty air filter(s) or air flow

restricted.

6.     Defective fan or relay.

 

Fan is not running. Dehumidification or fan is being called for.

1.     Loose connection in fan circuit.

2.     Obstruction prevents fan impeller rotation.

3.     Defective fan.

4.     Defective fan relay.

Troubleshooting (Continued)

Symptom Possible Reason Troubleshooting Procedure
 

 

Low dehumidification capacity (evaporator is frosted continuously).

Dehumidification is

being called for.

 

1.     Defrost thermostat loose or defective.

2.     Low refrigerant charge.

3.     Dirty air filter(s) or air

flow restricted.

4.     Excessively restrictive ducting connected to unit.

WARNING!

ELECTRICAL SHOCK HAZARD:

Electrical power must be present to perform some tests. These tests should be performed by a qualified service person.

Troubleshooting Procedure for Control Related Issues

This method of diagnosis is used to function check the internal components in the dehumidifier. This is to be used when a performance issue is suspected.

1.     Set the humidity controller all the way to the most humid setting or off position – Did the unit shut off?

2.     If yes, turn the fan setting to the ON position

– does the fan start?

3.     If fan starts, leave in the fan ON position and set the humidity all the way to driest setting. May have to wait 5 minutes for the compressor to start.

4.     Listen for a distinct buzzing/humming sound of a compressor starting up – do you hear this noise?

5.     If compressor is running and continues to run, after about 15 minutes you should feel a slight increase in air temperature being discharged out of the discharge air side of the unit.

6.     If so, depending on your environmental conditions (temp/Rh%), you should see some water production out of the hose within 30 minutes or so. (Note: If the room temperature is 55 degrees or below and/ or in area of low relative humidity, the

dehumidifier will produce little to no water.)

7.     Collecting the water removed in a 24 hour period will give a measurement of performance.

 

 

 

No ventilation. Ventilation is being called for.

 

1.     Loose connection in ventilation control circuit.

2.     Loose connection in damper power circuit.

3.     Defective outdoor air damper.

 

 

 

 

 

 

Dehumidifier removes some water, but not as much as expected.

 

1.     Air temperature and/or humidity have dropped.

2.     Humidity meter and or thermometer used are out of calibration.

3.     Unit has entered defrost cycle.

4.     Dirty air filter(s) or air

flow is restricted.

5.     Defective defrost thermostat.

6.     Low refrigerant charge.

7.     Air leak such as loose cover or ducting leaks.

8.     Defective compressor.

9.     Restrictive ducting.

 Refrigerant Charging

WARNING!

SERVICING THE SANTA FE ULTRA98/120 WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR PROPERTY DAMAGE. SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. If the refrigerant charge is lost due to service or a leak, the leak should be repaired and a new charge must be accurately weighed in. If any of the old charge is left in the system, it must be recovered before weighing in the new charge. Refer to the unit nameplate for the correct charge weight and refrigerant type.

WARRANTY

Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as follows:

  1. the Santa Fe Ultra98/120 dehumidifier (“Product”) will be free of material defects in workmanship or materials for a period of two (2) years (“Two-Year Warranty”) following the date of initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (“Customer”), and
  2. the Product’s components will be free of material defects in workmanship or materials for a period of six (6) years following the date of initial purchase of such Product by a Customer.

Limitation of Remedies. CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THE ABOVE LIMITED WARRANTY AND THERMA- STOR’S ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE OPTION OF THERMA-STOR, REPLACEMENT OR REPAIR
OF SUCH PRODUCT OR ITS COMPONENTS (“COMPONENTS”) BY THERMA-STOR OR THERMA-STOR’S AGENTS ONLY. REFRIGERANT, PIPING, SUPPLIES, TRANSPORTATION COSTS, LABOR COSTS INCURRED IN REPAIR OR REPLACEMENT OF SUCH COMPONENTS ARE NOT INCLUDED. THIS DISCLAIMER AND EXCLUSION SHALL APPLY EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. CUSTOMER ACKNOWLEDGES THAT NO REPRESENTATIVE OF THERMA-STOR OR OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTY ON BEHALF OF THERMA-STOR OR ANY OF ITS AFFILIATES OR RESELLERS THAT IS NOT IN THIS AGREEMENT. Notwithstanding the above, during the term of the Two-Year Warranty only, Therma-Stor will provide, free of charge to Customer, all Components and labor (except costs related to removal and installation of Product) required to fulfill its obligations under such Two-Year Warranty.
Disclaimer of Warranties. EXCEPT FOR ABOVE LIMITED WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS, THERMA-STOR HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES,

INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Warranty Limitations. The foregoing limited warranty extends only to a Customer and shall be null and void upon attempted assignment or transfer. A “defect” under the terms of the limited warranty shall not include problems resulting from Customer’s or Customer’s employees’, agents’, invitees’ or a third party’s misuse, improper installation, improper design of any system in which the Product is included, abuse, lack of normal care, failure to follow written instructions, tampering, improper repair, or freezing, corrosion, acts of nature or other causes not arising out of defects in Therma-Stor’s workmanship or material. If a Product or Component is replaced while under warranty, the applicable limited warranty period shall not be extended beyond the original warranty time period. The limited warranty does not cover any costs related to changes to a Product or Component that may be required by any codes, laws, or regulations that may become effective after initial purchase of the Product by Customer. Customer Responsibilities. As a further condition to obtaining warranty coverage hereunder, the Customer must send a valid warranty claim to Therma-Stor such that Therma-Stor receives such claim prior to the end of the applicable warranty period. Therma-Stor shall have no obligation hereunder with respect to any claim received by Therma-Stor after the expiration of the applicable warranty period.

As a further condition to obtaining warranty coverage hereunder, the Customer must present forms of invoices evidencing proof of purchase of a Product. If such invoices do not clearly indicate the date of initial purchase by a Customer, the applicable Product’s date of manufacture will be used instead of the date of initial purchase for the purpose of calculating the commencement of the applicable warranty period. Warranty service must be performed by Therma-Stor or a servicer authorized by Therma-Stor. In order to obtain warranty service, the Customer should call Therma-Stor at 1-800-533-7533 and ask for the Therma-Stor Products Service Department, which will then arrange for applicable warranty service. Warranty service will be performed during customary, daytime working hours. If the Product must be shipped for service, Customer shall be solely responsible for properly packaging the Product, for all freight charges, and for all risk of loss associated with shipment.

Limitation of Liability. IN NO EVENT SHALL THERMA-STOR, IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE, REPAIR, REPLACEMENT OR PERFORMANCE OF ANY PRODUCT, COMPONENT, PART THEREOF OR WRITTEN MATERIAL PROVIDED THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL, DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. NOTWITHSTANDING THE ABOVE LIMITATIONS AND WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF THERMA-STOR, REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM, SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE OF THE PRODUCT, COMPONENT OR PART UPON WHICH THE CLAIM IS PREMISED.

Applicable Law and Venue. ANY ARBITRATION, ENFORCEMENT OF AN ARBITRATION OR LITIGATION RELATED TO THE PRODUCT WILL BE BROUGHT EXCLUSIVELY IN DANE COUNTY, WISCONSIN, AND CUSTOMER CONSENTS TO THE JURISDICTION OF THE FEDERAL AND STATE COURTS LOCATED THEREIN, SUBMITS TO THE JURISDICTION THEREOF AND WAIVES THE RIGHT TO CHANGE VENUE. CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO ANY SUCH PROCEEDING.

Miscellaneous. If any term or condition of this Limited Warranty is found by a court of competent jurisdiction to be invalid, illegal or otherwise unenforceable, the same shall not affect the other terms or conditions hereof or thereof or the whole of this Limited Warranty. Any delay or failure by Therma-Stor to exercise any right or remedy will not constitute a waiver of Therma- Stor to thereafter enforce such rights.

Documents / Resources

Santa Fe Ultra Series Relative Humidity Control [pdf] Instructions
Ultra Series, Ultra Series Relative Humidity Control, Relative Humidity Control, Humidity Control, Control