Instructions for Santa Fe models including: Ultra70, DEH 3000, Ultra Series Relative Humidity Control, Ultra Series, Relative Humidity Control, Humidity Control

1. Recommended HVAC System Installations a. Attic

1. Recommended HVAC System Installations a. Attic The recommended installation draws air from a central location through a dedicated return to the

Ultra70 Recommended Installation

Ultra Aire 70H Dehumidifier | Whole House Ventilating Dehumidifier

PDF preview unavailable. Download the PDF instead.

Ultra70-Recommended-Installs
1. Recommended HVAC System Installations

a. Attic
The recommended installation draws air from a central location through a dedicated return to the dehumidifier and ducts the supply of the dehumidifier to the air supply of the HVAC system. Utilize the optional outdoor air ventilation duct to provide outdoor air.
· Install a dedicated 8" air return for the Santa Fe Ultra70 from a central area of the structure.
· Duct the supply of the Santa Fe Ultra70 to the supply of the HVAC system with a backdraft damper.
· If the existing system has multiple returns, instead of installing a dedicated return to the Santa Fe Ultra70, it is possible to select one to disconnect from the existing HVAC system and use it for the dedicated Santa Fe Ultra70 return. Select a return from a central location in the house that is always open to the rest of the structure. DO NOT use a return from a room where doors are kept closed.
· DO NOT locate return in a bathroom or kitchen.
· Control should be located remotely from the dehumidifier and placed in a central location.

Dedicated Santa Fe Return to HVAC Supply

Optional Outdoor Air
Intake

HVAC Return

Air Handler

HVAC Supply

Motorized Damper
Ultra Series Indoor Air Return

Backdraft Damper
Ultra Series Supply

b. Installation in a Basement or Crawlspace
Install a separate 8" return for the Ultra70 in a central area of the structure. Duct the supply of the dehumidifier to the air supply of the HVAC system with a backdraft damper.
Optional: Duct the supply of the Ultra70 to a 8" x 8" x 8" tee/damper with a gravity draft damper, adjust-
ed to 20% open to the basement. CAUTION: Air takes the path of least resistance. If the upper levels of the living space are not receiving the appropriate amount of dry air, this damper may need to be adjusted. When the dehumidifier is not running, there is a chance that air from the basement or crawlspace will make its way back through the gravity damper and into the living space.

Ultra Series Indoor
Air Return

HVAC Supply

DEH 3000 control

HVAC Return

Backdraft Damper

Motorized Damper
Optional Outdoor Air Intake

Optional Duct Tee & Gravity Damper

Dry Air to Basement

