ROSA LED Drop Owner’s Manual

ROSA LED Drop Owner’s Manual
LED Drop

TECHNICAL DATA

Application residential roads (internal), surrounding oce buildings, parks, pedestrians
Assembly on extension arms with ⌀ 42 x 30 mm ending
Colour inox / graphite
Ingress protection IP 66
Optical system PMMA optics
Material anodised aluminium alloy
Expected useful lifetime L90B10 – 100 000 h
CRI >70
Inrush current 21A / 225µs
Input voltage frequency 50/60Hz
Power factor ≥0.95
Number of LED 16
Control system Luminaire has the possibility to connect to an external control system via DALI interface (optionally via analog signal 1- 10V).
Code Symbol LED power Luminaire power consumption LED forward current Colour temperature (CCT) LEDs luminous flux Luminaire luminous flux¹ Luminous ecacy¹ Unit volume Net weight
214930/6/…² DROP LED 24 24 W 28 W 500 mA 5000 K 4350 lm 4150 lm 148 lm/W 0.041 m³ 4.9 kg
  1. tolerance +/- 5% due to LEDs accuracy
  2. symbol of chosen optical system eg. 214933/6/S is DROP LED 48 5000K with symetric optical system

DIRECTIVES AND STANDARDS

DIRECTIVES: 2014/35/UE (Official Journal of the UE L 96/357 29.03.2014), 2014/30/UE (Official Journal of the UE L 96/79 29.03.2014), 2011/65/UE, 2009/125/EC STANDARDS: –

CHARGING DISCHARGE FROM THE LED LUMINAIRE HOUSING

In order to efficient discharge the electrostatic charge from the housing of LED fitting installed on the pole from dielectric material (non-conductive) one of the following solutions is required:

  • functional grounding
  • LED luminaire with an additional protection device

TECHNICAL DRAWING

Dimension

PHOTOMETRIC CURVES

Dimension

POWER SYSTEM FUNCTIONS

Luminaire in standard has following functions of intelligent power supply:

  • Connection to outside control system by DALI interface (operation of analog signal 1-10V as an option),
  • Possibility of programming multistage dimming of luminaire, up to 5 intervals in the range of from 10 to 100% of nominal power,
  • Temperature protection of LED module (from overheating) in case of unintentional luminaire operation during the,
  • Regulation of power / luminous ux – the option of setting another value than the catalogue in the range of 30-100% of nominal one,

ACCETABLE QUANTITY OF LUMINAIRES ON ONE CIRCUIT

Overcurrent switches MCB type B or C

Luminaire Typ 2A 4A 6A 10A 16A 20A 25A
DROP LED 48 B 1 2 4 6 12 12 15
C 1 4 6 10 17 20 26
DROP LED 24, 36 B 3 6 10 16 26 32 40
C 3 10 16 27 44 54 67

Fuse – type gG and GL

Luminaire 2A 4A 6A 10A 16A 20A 25A
DROP LED 48 0 4 8 11 22 31 44
DROP LED 24, 36 1 10 19 25 50 68 97

Zakład Produkcji Sprzętu Oświetleniowego „ROSA” Sp. z o.o.
43-109 Tychy, ul. Strefowa 1 tel. +48 32 73 88 901