R V R logoCHANGEOVER UNITS SYSTEM
SCM
MODELS
SCMLCD1+1 SCML1+1SL SCMLCDN+1
SCMMAN1+1/158 SCM6-1R V R SCMLCD1 1 Changeover Units System SCM

To ensure the continuity of transmission of the transmitting equipment, RVR produces various models of changeover units for the control of redundant configurations in 1 + 1 and N + 1 up to 6 + 1.
By integrating coaxial relays, distributors and Audio, MPX and RDS routers, it is thus possible to manually or automatically switch the reserve transmission in case of failure of one of the main ones.
Depending on the architecture of the transmitting site, dedicated models are available.

ORDERING INFORMATION

Model Description
SCMLCD1+1 Telemetry automatic changeover unit.
OPTION
SCMLCD1+1/T0 Automatic changeover “1+1” unit and telemetry unit with Nr 1 I/O base card on board.
SCMLCD1+1/T1 Automatic changeover “1+1” unit and telemetry unit with Nr 1 I/O additional card on board.
SCMLCD1+1/T2 Automatic changeover “1+1” unit and telemetry unit with Nr 2 I/O additional cards on board.
SCMLCD1+1/T3 Automatic changeover “1+1” unit and telemetry unit with Nr 3 I/O additional cards on board.
Model Description
SCML1+1SL Compact exchange unit for 1 + 1 systems with coaxial relays of any size.
OPTION
SCML1+1SL/V1 Automatic Changeover “1+1” unit with 4 ways external relay. Power: min 150W max 1 kW. Without Telemetry.
SCML1+1SL/V2 Automatic Changeover “1+1” unit with 3 ways internal relay. Power: min OW max 150W. Without Telemetry.
SCML1+1SL/V3 Automatic Changeover “1+1” unit with 4 ways external relay. Power: from lkW up. Without Telemetry.
SCML1+1SL/V4 Automatic Changeover “1+1” unit with customized relay. Without Telemetry.
Model Description
SCMMAN1+1/158 Manual changeover function across main and spare transmitter by coaxial relay control panel.
Model Description
SCMLCDN+1 RVR changeover system is equipped with an on-board telemetry unit so that it guarantee utmost continuous service.
OPTION
SCMLCDN+1/T0 Automatic Changeover “N+1” and telemetry unit with No. 2 I/O base cards on board.
SCMLCDN+1/T1 Automatic Changeover “N+1” and telemetry unit with No. 3 I/O base cards on board.
SCMLCDN+1/T2 Automatic Changeover “N+1” and telemetry unit with No. 4 I/O base cards on board.
Model Description
SCM6-1 Automatic Changeover “N+1”, up to 6 transmitters, with integrated telemetry.

R V R SCMLCD1 1 Changeover Units System SCM - Fig 1

SCMLCD 1+1
Changeover Units System.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 1

https://www.rvr.it/it/products/components/changeover-units-system/1-1-changeover-system/scmlcd1-1/

R V R SCMLCD1 1 Changeover Units System SCM - Fig 2

SCML1+1SL
Changeover Units System.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 2

R V R SCMLCD1 1 Changeover Units System SCM - Fig 3

SCMMAN1+1/158
Changeover Units System.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 3

https://www.rvr.it/it/products/components/changeover-units-system/1-1-changeover-system/scmman1-1-158/

R V R SCMLCD1 1 Changeover Units System SCM - Fig 4

SCMLCDN+1
Changeover Units System.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 4

https://www.rvr.it/it/products/components/changeover-units-system/4-1-changeover-system/scmlcdn-1-scmlcdn-1/

R V R SCMLCD1 1 Changeover Units System SCM - Fig 5

SCM6-1
Changeover Units System.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 5

https://www.rvr.it/it/products/components/changeover-units-system/change-over/scm6-1-scm6-1/

SCMLCD1+1

Parameters Value Notes
GENERALS
Integrated coax-relè                        Only / V2 Yes
Ambient working temperature -10 °C to + 50 °C / 95% Relative humidity non condensing
POWER REQUIREMENTS
AC Power input AC Supply voltage 115 – 125 – 230 – 250 VAC ±15%
AC Apparent power consumption W
Connector VDE IEC Standard
DC Power input DC Supply voltage 24 VDC
DC Current A
MECHANICAL DIMENSIONS
Phisical dimensions  L x H x W mm / inch 483 EIA rack
mm / inch 88 / 3 1/2 2HE
Weight kg About 4
Cooling Convection cooling
Acoustic noise dBA 0
AUDIO INPUTS
Analog 8 ÷ 32 Analog inputs depending by expansion card number.
Digital / Analog 16 ÷ 64 Digital inputs depending by expansion card number.
OUTPUTS
Relay 8 ÷ 32 Analog inputs depending by expansion card number.
FUSES
On mains 1 External fuse 4 A F – 5X20 mm
On services X
On PA Supply X
On driver supply X

SCML1+1SL

Parameters Value Notes
GENERALS
Integrated coax-relè                         only / V2 Yes
Ambient working temperature -10 °C to + 50 °C / 95% Relative humidity non condensing
POWER REQUIREMENTS
AC Power input AC Supply Voltage 115 – 125 – 230 – 250 VAC ±15%
AC Apparent Power Consumption W
Connector VDE IEC Standard
DC Power input DC Supply Voltage 24 VDC
DC Current A
MECHANICAL DIMENSIONS
Phisical dimensions L x H x W mm / inch 483 / 19 EIA rack
mm / inch 44 / 3 1/2 1HE
Weight kg About 0,3
Cooling Convection cooling
Acoustic noise dBA 0
AUDIO INPUTS
Analog Specific RVR connectors
Digital / Analog Specific RVR connectors
OUTPUTS
Relay Specific RVR connectors
INTERFACES
User interface LCD – 2 x 16 with Encoder
Signaling LEDs / Synoptically Yes
I2C Yes
TC/TS Yes
FUSES
On mains 1 External fuse 1,6 A T – 5X20 mm
On services X
On PA Supply X
On driver supply X

SCMMAN1+1/158

Parameters Value Notes
GENERALS
Ambient working temperature -10 °C to + 50 °C / 95% Relative humidity non condensing
AC Power input AC Supply Voltage 115 – 230 VAC ±15%
AC Apparent Power Consumption W 2
Connector Terminal Block (L-N-PE)
MECHANICAL DIMENSIONS
Phisical dimensions              L x H x W mm / inch 483 EIA rack
mm / inch 88 / 3 1/2 2HE
Weight kg About 0,3
Cooling Convection cooling
Acoustic noise dBA 0
INTERFACES
Signalling LEDs / Synoptical LOCAL mm Yellow 5
TX1 to ANT mm 2 x Green 5
TX2 to ANT mm 2 x Yellow 5
Push button LOCAL ENABLE Used for enabling change whit push button
TX1 to ANT Used for change Relay in a POS1
TX2 to ANT Used for change Relay in a POS2
AUDIO INPUTS
Digital Command Switch relay Terminal Block
OUTPUTS
Digital Position Switch relay Terminal Block
Digital Out of Position Relay Terminal Block
FUSES
On mains 1 Fuse 125mA – 5X20 mm
On services X
On PA Supply X
On driver supply X

SCMLCDN+1

Parameters Value Notes
GENERALS
Integrated coax-relè                       Only / V2 Yes
Ambient working temperature -10 °C to + 50 °C / 95% Relative humidity non condensing
POWER REQUIREMENTS
AC Power input AC Supply voltage 115 – 125 – 230 – 250 VAC ±15%
AC Apparent power consumption W
Connector VDE IEC Standard
DC Power input DC Supply voltage 24 VDC
DC Current A
MECHANICAL DIMENSIONS
Physicals dimensions   L x H x W mm / inch 483 EIA rack
mm / inch 88 / 3 1/2 2HE
Weight kg About 4
Cooling Convection cooling
Acoustic noise dBA 0
AUDIO INPUTS
Analog 8 ÷ 32 Analog inputs depending by expansion card number
Digital / Analog 16 ÷ 64 Digital inputs depending by expansion card number
OUTPUTS
Relay 8 ÷ 32 Analog inputs depending by expansion card number
INTERFACES
User interface Graphical LCD – 128 x 64 with Encoder
Signaling LEDs / synoptically Yes
I2C Yes
RS232 Yes
FUSES
On mains 1 External fuse 4 A F – 5X20 mm
On services X
On PA Supply X
On driver supply X

SCM6/1

Parameters Value Notes
GENERALS
Ambient working temperature -10 °C to + 50 °C / 95% Relative Humidity non condensing
POWER REQUIREMENTS
AC Power input AC Supply voltage 115 – 125 – 230 – 250 VAC ±15%
AC Apparent power consumption W 50
Connector VDE IEC Standard
DC Power input DC Supply voltage 24 VDC
DC Current <2 a
MECHANICAL DIMENSIONS
Physicals dimensions   L x H x W mm / inch 483 EIA rack
mm / inch 176 / 3 1/2 4HE
Weight kg About 6,5
Cooling Forced with internal fans
Acoustic noise dBA <58
AUDIO INPUTS
Digital
OUTPUTS
Relay Specific RVR connectors
INTERFACES
User interface Graphical LCD – 240 x 128 with Encoder
Signaling LEDs / synoptically Yes
TC/TS Yes
FUSES
On mains 1 External fuse 4 A – 5X20 mm
On services X
On PA Supply X
On driver supply X

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

R V R SCMLCD1 1 Changeover Units System SCM - Qr Code 6

https://www.rvr.it

R V R logoR.V.R. Elettronica S.r.l.
Via del Fonditore, 2/2c
40138 Bologna Italy
Phone +39 0516010506
Fax +39 0516011104
sales@rvr.it
www.rvr.it

R V R logo 2

Documents / Resources

R V R SCMLCD1+1 Changeover Units System SCM [pdf] User Manual
SCMLCD1 1 Changeover Units System SCM, SCMLCD1 1, Changeover Units System SCM, Units System SCM, System SCM

References

Leave a comment

Your email address will not be published. Required fields are marked *