User Manual for R V R models including: SCMLCD1 1 Changeover Units System SCM, SCMLCD1 1, Changeover Units System SCM, Units System SCM, System SCM

TECHNICAL SHEET-SCM SERIES

R.V.R. Elettronica - Broadcast Systems - Manuals


File Info : application/pdf, 8 Pages, 733.64KB

PDF preview unavailable. Download the PDF instead.

scm series qr
CHANGEOVER UNITS SYSTEM

SCM

CHANGEOVER UNITS SYSTEM
SCM
MODELS

SCMLCD1+1 SCML1+1SL SCMLCDN+1 SCMMAN1+1/158 SCM6-1

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

1

Via del Fonditore, 2/2c

Fax +39 0516011104

40138 Bologna Italy

CHANGEOVER UNITS SYSTEM

SCM

To ensure the continuity of transmission of the transmitting equipment, RVR produces various models of changeover units for the control of redundant configurations in 1 + 1 and N + 1 up to 6 + 1.

By integrating coaxial relays, distributors and Audio, MPX and RDS routers, it is thus possible to manually or automatically switch the reserve transmission in case of failure of one of the main ones. Depending on the architecture of the transmitting site, dedicated models are available.

ORDERING INFORMATION

Model

Description

SCMLCD1+1

Telemetry automatic changeover unit.

OPTION

SCMLCD1+1/T0

Automatic changeover "1+1" unit and telemetry unit with Nr 1 I/O base card on board.

SCMLCD1+1/T1

Automatic changeover "1+1" unit and telemetry unit with Nr 1 I/O additional card on board.

SCMLCD1+1/T2

Automatic changeover "1+1" unit and telemetry unit with Nr 2 I/O additional cards on board.

SCMLCD1+1/T3

Automatic changeover "1+1" unit and telemetry unit with Nr 3 I/O additional cards on board.

ORDERING INFORMATION

Model

Description

SCML1+1SL

.

OPTION

SCML1+1SL/V1

SCML1+1SL/V2

SCML1+1SL/V3

SCML1+1SL/V4

Automatic Changeover "1+1" unit with customized relay. Without Telemetry.

ORDERING INFORMATION

Model

Description

SCMMAN1+1/158

Manual changeover function across main and spare transmitter by coaxial relay control panel.

ORDERING INFORMATION

Model

Description

SCMLCDN+1

RVR changeover system is equipped with an on-board telemetry unit so that it guarantee utmost continuous service.

OPTION

SCMLCDN+1/T0

Automatic Changeover "N+1" and telemetry unit with No. 2 I/O base cards on board.

SCMLCDN+1/T1

Automatic Changeover "N+1" and telemetry unit with No. 3 I/O base cards on board.

SCMLCDN+1/T2

Automatic Changeover "N+1" and telemetry unit with No. 4 I/O base cards on board.

ORDERING INFORMATION

Model

Description

SCM6-1

Automatic Changeover "N+1", up to 6 transmitters, with integrated telemetry.

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

Via del Fonditore, 2/2c

Fax +39 0516011104

2

40138 Bologna Italy

CHANGEOVER UNITS SYSTEM

SCM

1 Changeover Units System.

SCML1+1SL Changeover Units System.
SCMMAN1+1/158 Changeover Units System.

SCMLCDN+1 Changeover Units System.
SCM6-1 Changeover Units System.

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

3

Via del Fonditore, 2/2c

Fax +39 0516011104

40138 Bologna Italy

CHANGEOVER UNITS SYSTEM

SCM

SCMLCD1+1

Parameters GENERALS Integrated coax-relè

Only / V2

Ambient working temperature

POWER REQUIREMENTS

AC Supply voltage

AC Power input

AC Apparent power consumption Connector

DC Power input

DC Supply voltage DC Current

MECHANICAL DIMENSIONS
Phisical dimensions
Weight Cooling Acoustic noise AUDIO INPUTS Analog
Digital / Analog OUTPUTS Relay FUSES On mains On services On PA Supply On driver supply

L x H x W

Value

Notes

Yes -10 °C to + 50 °C / 95%

Relative humidity non condensing

115 - 125 - 230 - 250 VAC ±15%
W VDE IEC Standard
24 VDC A

mm / inch mm / inch
kg
dBA

483 88 / 3 1/2 About 4 Convection cooling
0

EIA rack 2HE

8 ÷ 32 16 ÷ 64

Analog inputs depending by expansion card number. Digital inputs depending by expansion card number.

8 ÷ 32

Analog inputs depending by expansion card number.

1 External fuse 4 A F - 5X20 mm X X X

SCML1+1SL

Parameters
GENERALS Integrated coax-relè

only / V2

Ambient working temperature

POWER REQUIREMENTS

AC Supply Voltage

AC Power input
DC Power input MECHANICAL DIMENSIONS

AC Apparent Power Consumption Connector DC Supply Voltage DC Current

Phisical dimensions

L x H x W

Weight
Cooling
Acoustic noise AUDIO INPUTS Analog
Digital / Analog OUTPUTS Relay

INTERFACES User interface Signalling LEDs / Synoptical I2C TC/TS
FUSES On mains On services On PA Supply On driver supply

Value
Yes -10 °C to + 50 °C / 95%

Notes Relative humidity non condensing

115 - 125 - 230 - 250 VAC ±15%
W VDE IEC Standard
24 VDC A

mm / inch mm / inch
kg
dBA

483 / 19 44 / 3 1/2
About 0,3
Convection cooling 0

EIA rack 1HE

Specific RVR connectors Specific RVR connectors
Specific RVR connectors

LCD - 2 x 16 with Encoder
Yes Yes Yes

1 External fuse 1,6 A T - 5X20 mm X X X

All pictures are RVR's property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

Via del Fonditore, 2/2c

Fax +39 0516011104

4

40138 Bologna Italy

CHANGEOVER UNITS SYSTEM

SCM

SCMMAN1+1/158

Parameters
GENERALS Ambient working temperature

POWER REQUIREMENTS

AC Supply Voltage

AC Power input

AC Apparent Power Consumption Connector

MECHANICAL DIMENSIONS

Phisical dimensions

L x H x W

Weight

Cooling

Acoustic noise

INTERFACES

LOCAL

Signalling LEDs / Synoptical TX1 to ANT TX2 to ANT

Push button

LOCAL ENABLE
TX1 to ANT TX2 to ANT

AUDIO INPUTS Digital

OUTPUTS Digital

Digital
FUSES On mains On services On PA Supply On driver supply

Value -10 °C to + 50 °C / 95%

Notes Relative humidity non condensing

115 - 230 VAC ±15%

W

2

Terminal Block (L-N-PE)

mm / inch mm / inch
kg
dBA

483 88 / 3 1/2 About 0,3 Convection cooling
0

EIA rack 2HE

mm

Yellow 5

mm

2 x Green 5

mm

2 x Yellow 5

Used for enabling change whith push button

Used for change Relay in a POS1

Used for change Relay in a POS2

Command Switch relay

Terminal Block

Position Switch relay Out of Position Relay

Terminal Block Terminal Block

1 Fuse 125mA - 5X20 mm X X X

SCMLCDN+1

Parameters GENERALS Integrated coax-relè Ambient working temperature

Only / V2

POWER REQUIREMENTS AC Power input DC Power input

AC Supply voltage AC Apparent power consumption Connector
DC Supply voltage DC Current

MECHANICAL DIMENSIONS

Phisical dimensions

L x H x W

Weight
Cooling
Acoustic noise AUDIO INPUTS Analog

Digital / Analog OUTPUTS Relay

INTERFACES User interface Signalling LEDs / synoptical I2C RS232
FUSES On mains On services On PA Supply On driver supply

Value
Yes -10 °C to + 50 °C / 95%

Notes Relative humidity non condensing

115 - 125 - 230 - 250 VAC ±15%
W VDE IEC Standard
24 VDC A

mm / inch mm / inch
kg
dBA

483 88 / 3 1/2
About 4 Convection cooling
0
8 ÷ 32 16 ÷ 64
8 ÷ 32

EIA rack 2HE
Analog inputs depending by expansion card number Digital inputs depending by expansion card number Analog inputs depending by expansion card number

Graphical LCD - 128 x 64 with Encoder
Yes Yes Yes

1 External fuse 4 A F - 5X20 mm X X X

All pictures are RVR's property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

5

Via del Fonditore, 2/2c

Fax +39 0516011104

40138 Bologna Italy

CHANGEOVER UNITS SYSTEM

SCM

SCM6/1

Parameters

GENERALS Ambient working temperature

POWER REQUIREMENTS

AC Supply voltage

AC Power input

AC Apparent power consumption Connector

DC Power input

DC Supply voltage DC Current

MECHANICAL DIMENSIONS

Phisical dimensions

L x H x W

Weight
Cooling Acoustic noise AUDIO INPUTS Digital OUTPUTS Relay INTERFACES User interface
Signalling LEDs / synoptical
TC/TS FUSES On mains On services On PA Supply On driver supply

Value -10 °C to + 50 °C / 95%

Notes Relative Humidity non condensing

115 - 125 - 230 - 250 VAC ±15%

W

50

VDE IEC Standard

24 VDC <2 a

mm / inch mm / inch
kg
dBA

483 176 / 3 1/2 About 6,5 Forced with internal fans
<58

EIA rack 4HE

Specific RVR connectors
Graphical LCD - 240 x 128 with Encoder Yes Yes
1 External fuse 4 A - 5X20 mm X X X

All pictures are RVR's property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

Via del Fonditore, 2/2c

Fax +39 0516011104

6

40138 Bologna Italy

R.V.R. Elettronica S.r.l.

Phone +39 0516010506

7

Via del Fonditore, 2/2c

Fax +39 0516011104

40138 Bologna Italy

R.V.R. Elettronica S.r.l. Via del Fonditore 2/2 40138 Bologna - ltaly Phone +39 0516010506 sales@rvr.it www.rvr.it



References