Planet Technology IGS-5227-6T,IGS-5227-6MT-X Managed Ethernet Switch
Package Contents
Thank you for purchasing PLANET Industrial L2+ Managed Ethernet Switch. The descriptions of this series are shown below:
IGS-5227-6T | Industrial IP67-rated 6-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C) |
IGS-5227-6MT-X |
Industrial IP67-rated 6-Port 10/100/1000T M12 Managed Ethernet Switch (-40~75 degrees C, X-coded M12) |
“Industrial Managed Switch” is used as an alternative name in this Quick Installation Guide.
Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items:
If any item is found missing or damaged, please contact your local reseller for replacement.
Making Waterproof RJ45 Cable (IGS-5227-6T)
Please read the following instructions and follow the procedures in the order being presented:
- Step 1: Take a waterproof RJ45 jack out from the Industrial Managed Switch box and get hold of one RJ45 cable.
- Step 2: Insert the RJ45 cable through the waterproof RJ45 jack.
- Step 3: Prepare an RJ45 connector.
- Step 4: Put the RJ45 connector in place with cable crimper.
NOTE
The standard RJ45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color coded. The following shows the pin allocation and colors of straight-through cable connection:Please make sure your waterproof RJ45 cables are with same pin assignment and colors as the above picture before deploying the cables into your network.
- Step 5: To lock in the RJ45 connector, pull back the cable till the connector nicely fits into the waterproof connector hole.
NOTE
- Use only the waterproof RJ45 connector provided in the package of the IGS-5227-6T.
- If the waterproof RJ45 connector is found missing or damaged, please contact your local reseller where you purchased from. If the new waterproof RJ45 connector is obtained from PLANET, make sure its dimensions are the same.
- Never use any waterproof RJ45 connector that is not purchased from PLANET or doesn’t have the same dimensions of the IGS-5227-6T; it will damage the device permanently.
Connecting Waterproof Cable to the IGS-5227-6T
NOTE
Follow all the connecting waterproof cable steps as shown in the example.
- Step 1: Turn counterclockwise to remove the waterproof screw nuts of a RJ45 port and power input.
- Step 2: Insert the waterproof RJ45 connector into the port of the Industrial Managed Switch.
- Step 3: Turn clockwise to tighten the screw nut of the waterproof RJ45 connector.
- Step 4: Insert the waterproof M12 power connector into the port of the power input.
- Step 5: Turn clockwise to tighten the screw nut of the waterproof M12 power connector.
CAUTION
To have the waterproof effect, connectors must be totally tightened, otherwise, it would invalidate your warranty.
NOTE
Before connecting the DC power cord, please check whether your local DC power source is stable.
M12 X-coded Connector Pin Assignment
The IGS-5227-6MT-X front panel provides six 10/100/1000BASE-T Ethernet ports in the form of M12 8-pin X-coded female connector. These ports are designed for Ethernet equipment connection through Cat5/5e UTP cables. The M12 8-pin X-coded input interface pinout is shown below:
8-pin M12 X-coded Female 10/100/1000T Connector Pin Assignment
M12 (8-pin, X-coded Male) to RJ45 (8-pin) Straight-through UTP Cabling
M12 X-coded Male Connector Pin No. | MDI 1000BASE-T Signal ID | T568B Color | RJ45 Connector Pin No. |
1 | BI_DA+ | white/orange | 1 |
2 | BI_DA- | orange | 2 |
3 | BI_DB+ | white/green | 3 |
4 | BI_DB- | green | 6 |
5 | BI_DD+ | white/brown | 7 |
6 | BI_DD- | brown | 8 |
7 | BI_DC- | White/blue | 5 |
8 | BI_DC+ | blue | 4 |
NOTE
As each Ethernet port of the Industrial Managed Switch is running in auto negotiation mode, make sure the Ethernet ports of the corresponding Ethernet devices are also running in auto negotiation mode; otherwise, the Ethernet performance will be poor.
Connecting M12 Cable to the IGS-5227-6MT-X
NOTE
Follow all the connecting M12 cable to the IGS-5227-6MT-X steps as shown in the example.
- Step 1: Turn counterclockwise to remove the waterproof screw nuts of an M12 connector and power input.
- Step 2: Insert the M12 UTP male connector into the M12 female Gigabit Ethernet port of the Industrial Managed Switch.
- Step 3: Turn clockwise to tighten the screw nut of the M12 connector and make sure the connection is tight.
- Step 4: Insert the M12 power female connector into the M12 male port of the power input.
- Step 5: Turn clockwise to tighten the screw nut of the M12 power connector.
CAUTION
To have the waterproof effect, connectors must be totally tightened, otherwise, it would invalidate your warranty.
NOTE
Before connecting the DC power cord, please check whether your local DC power source is stable.
M12 DC Power Cable Pin Assignment
The front panel of the Industrial Managed Switch provides one M12 DC power 5-pin male connector for DC power input. Please use the power cable with the M12 DC power 5-pin female connector from the Industrial Managed Switch package for DC power input. The M12 DC power cable pin assignment is shown below:
M12 DC power cable pin assignment and wiring code | |||
V1 positive (+) pin = black cable | |||
V1 negative (-) pin = brown cable | |||
![]() |
|||
V2 positive (+) pin = blue cable | |||
V2 negative (-) pin = white cable |
NOTE
Make sure you connect the correct power pin to your DC power source.
- The wire gauge for the power cable should be in the range of 12 ~ 24 AWG.
- The DC power input range is 9 ~ 48V DC.
There are two methods to install the Industrial Managed Switch – DIN-rail mounting and wall-mount plate mounting. For more detailed information, please refer to Chapter 2.3 of the user’s manual.
Requirements
Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. Workstations are installed with Ethernet NIC (Network Interface Card)
Ethernet Port Connection
- Network cables — Use standard network (UTP) cables with RJ45 connectors.
- The above PC is installed with Web browser.
NOTE It is recommended to use Google Chrome or above to access the Indus-trial Managed Switch. If the Web interface of the Industrial Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.
Starting Web Management
The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Logging in to the Industrial Managed Switch
- Use Google Chrome or above Web browser and enter IP address http://192.168.0.100 (default IP address) to access the Web interface.
NOTE
The following console screen is based on the firmware version before May of 2025. - The following console screen is based on the firmware version before May of 2025. password “admin”. The login screen in Figure 9-2 appears.
Default Username: admin
Default Password: adminNOTE
The following web screen is based on the firmware version of May of 2025 or after. - When the following dialog box appears, please enter the default user name “admin” and the password. Refer to Section 9-3 to determine your initial login password.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: sw + the last 6 characters of the MAC ID in lowercase - After logging in, you will be prompted to change the initial password to a permanent one.
- After entering the password, the main screen appears as Figure 9-5 shows.
The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides.
NOTE
If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description.
Now, you can use the Web management interface to continue the Switch management. Please refer to the user’s manual for more details.
Saving Configuration via Web
To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot.
NOTE The following console screen is based on the firmware version before May of 2025.
- Click System, Save Startup Config.
- Press the “Save Configuration” button.
NOTE The following web screen is based on the firmware version of May of 2025 or after.
- Click the Save icon on the top Switch Menu bar.
- Press the “Save Configuration” button.
- Or the other way to save the setting is to Click Maintenance, Save Startup Config.
Recovering Back to Default Configuration
- IP address has been changed or admin password has been forgotten –
NOTE Follow all the recovering back to default configuration steps as shown in the example.
- Power off the Industrial Managed Switch and remove all the existing connections.
- Use the straight RJ45 cable to connect to port 1 and port 2 in the loop topology as shown below:
- Power on the Industrial Managed Switch and 6 LNK/ACT LEDs will be lit.
- Resetting Industrial Managed Switch to the factory default is done when 6 LNK/ACT LEDs are lit again.
- Remove the RJ45 cable from port 1 and port 2.
- Reset the Industrial Managed Switch to factory default configuration.
- The Industrial Managed Switch will then reboot and load the default settings. Please refer to Chapter 9 for details.
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
- PLANET online FAQ: https://www.planet.com.tw/en/support/faq
- Switch support team mail address: support@planet.com.tw
- IGS-5227-6T/IGS-5227-6MT-X User’s Manual: https://www.planet.com.tw/en/support/downloads?method=category&c1=industrial-ethernet&p=&type=3
(Please select your switch model name from the drop-down menu of Product Models.)
Copyright © PLANET Technology Corp. 2025
Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
FAQ
- Q: What should I do if any item is missing or damaged in the package?
A: If any item is found missing or damaged, please contact your local reseller for replacement. - Q: Can I use a different waterproof RJ45 connector with the IGS-5227-6T?
A: No, always use only the waterproof RJ45 connector provided in the package. Using a different connector may damage the device permanently.
Documents / Resources
![]() |
Planet Technology IGS-5227-6T,IGS-5227-6MT-X Managed Ethernet Switch [pdf] Installation Guide IGS-5227-6T, IGS-5227-6MT-X, IGS-5227-6T IGS-5227-6MT-X Managed Ethernet Switch, IGS-5227-6T IGS-5227-6MT-X, Managed Ethernet Switch, Ethernet Switch, Switch |