PLANET Industrial IP67-rated 6-Port Gigabit Managed Ethernet Switch
IGS-5227-6T/IGS-5227-6MT-X
Quick Installation Guide
1. Package Contents
Thank you for purchasing PLANET Industrial L2+ Managed Ethernet Switch. The descriptions of this series are shown below:
IGS-5227-6T | Industrial IP67-rated 6-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C) |
IGS-5227-6MT-X | Industrial IP67-rated 6-Port 10/100/1000T M12 Managed Ethernet Switch (-40~75 degrees C, X-coded M12) |
"Industrial Managed Switch" is used as an alternative name in this Quick Installation Guide.
Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items:
Item | IGS-5227-6T | IGS-5227-6MT-X |
---|---|---|
The Industrial Managed Switch | ■ | ■ |
Quick Installation Guide | ■ | ■ |
1.2m M12 Power Cable | ■ | ■ |
Waterproof RJ45 Connector | 6 | - |
2m 8-pin X-coded M12-to-RJ45 UTP Cable | ■ | ■ |
DIN-rail Kit | ■ | ■ |
Wall-mount Kit | ■ | ■ |
If any item is found missing or damaged, please contact your local reseller for replacement.
2. Making Waterproof RJ45 Cable (IGS-5227-6T)
Please read the following instructions and follow the procedures in the order being presented:
-
Take a waterproof RJ45 jack out from the Industrial Managed Switch box and get hold of one RJ45 cable.
[Image: Hand holding a waterproof RJ45 jack and an RJ45 cable]
-
Insert the RJ45 cable through the waterproof RJ45 jack.
[Image: RJ45 cable being inserted through a waterproof RJ45 jack]
-
Prepare an RJ45 connector.
[Image: Hand holding an RJ45 connector]
-
Put the RJ45 connector in place with cable crimper.
[Image: RJ45 connector being crimped onto a cable]
Note: The standard RJ45 receptacle/connector has 8 wires, each color-coded. The pin allocation and colors for straight-through cable connection are as follows:
SIDE 1 | SIDE 2 | |
---|---|---|
1 | White/Orange | White/Orange |
2 | Orange | Orange |
3 | White/Green | White/Green |
4 | Blue | Blue |
5 | White/Blue | White/Blue |
6 | Green | Green |
7 | White/Brown | White/Brown |
8 | Brown | Brown |
Please make sure your waterproof RJ45 cables have the same pin assignment and colors as the above picture before deploying the cables into your network.
To lock in the RJ45 connector, pull back the cable till the connector nicely fits into the waterproof connector hole.
[Image: Hand pulling back a cable to secure an RJ45 connector in a waterproof housing]
3. Connecting Waterproof Cable to the IGS-5227-6T
Follow all the connecting waterproof cable steps as shown in the example.
-
Turn counterclockwise to remove the waterproof screw nuts of a RJ45 port and power input.
[Image: Two PLANET switches, one with screw nuts being removed from ports]
-
Insert the waterproof RJ45 connector into the port of the Industrial Managed Switch.
[Image: Waterproof RJ45 connector being inserted into a switch port]
-
Turn clockwise to tighten the screw nut of the waterproof RJ45 connector.
[Image: Hand tightening a screw nut on a waterproof RJ45 connector on a switch]
-
Insert the waterproof M12 power connector into the port of the power input.
[Image: Waterproof M12 power connector being inserted into a switch power input port]
-
Turn clockwise to tighten the screw nut of the waterproof M12 power connector.
[Image: Hand tightening a screw nut on a waterproof M12 power connector on a switch]
Caution: To have the waterproof effect, connectors must be totally tightened; otherwise, it would invalidate your warranty.
Note: Before connecting the DC power cord, please check whether your local DC power source is stable.
4. M12 X-coded Connector Pin Assignment
The IGS-5227-6MT-X front panel provides six 10/100/1000BASE-T Ethernet ports in the form of M12 8-pin X-coded female connector. These ports are designed for Ethernet equipment connection through Cat5/5e UTP cables. The M12 8-pin X-coded input interface pinout is shown below:
[Diagram: Circular connector with 8 pins labeled 1 through 8, with pin 7 and 8 having a different orientation. A table shows pin assignments and corresponding signals.]
Pin | Con |
---|---|
1 | DA+ |
2 | DA- |
3 | DB+ |
4 | DB- |
5 | DD+ |
6 | DD- |
7 | DC- |
8 | DC+ |
8-pin M12 X-coded Female 10/100/1000T Connector Pin Assignment
5. M12 (8-pin, X-coded Male) to RJ45 (8-pin) Straight-through UTP Cabling
[Diagram: M12 8-pin X-coded male connector and an RJ45 8-pin connector connected by a cable.]
M12 X-coded Male Connector Pin No. | MDI 1000BASE-T Signal ID | T568B Color | RJ45 Connector Pin No. |
---|---|---|---|
1 | BI_DA+ | white/orange | 1 |
2 | BI_DA- | orange | 2 |
3 | BI_DB+ | white/green | 3 |
4 | BI_DB- | green | 6 |
5 | BI_DD+ | white/brown | 7 |
6 | BI_DD- | brown | 8 |
7 | BI_DC- | White/blue | 5 |
8 | BI_DC+ | blue | 4 |
Note: As each Ethernet port of the Industrial Managed Switch is running in auto negotiation mode, make sure the Ethernet ports of the corresponding Ethernet devices are also running in auto negotiation mode; otherwise, the Ethernet performance will be poor.
6. Connecting M12 Cable to the IGS-5227-6MT-X
Follow all the connecting M12 cable to the IGS-5227-6MT-X steps as shown in the example.
-
Turn counterclockwise to remove the waterproof screw nuts of an M12 connector and power input.
[Image: Two PLANET switches, one with screw nuts being removed from ports]
-
Insert the M12 UTP male connector into the M12 female Gigabit Ethernet port of the Industrial Managed Switch.
[Image: M12 UTP male connector being inserted into a switch's M12 female port]
-
Turn clockwise to tighten the screw nut of the M12 connector and make sure the connection is tight.
[Image: Hand tightening a screw nut on an M12 connector on a switch]
-
Insert the M12 power female connector into the M12 male port of the power input.
[Image: M12 power female connector being inserted into a switch's M12 male power input port]
-
Turn clockwise to tighten the screw nut of the M12 power connector.
[Image: Hand tightening a screw nut on an M12 power connector on a switch]
Caution: To have the waterproof effect, connectors must be totally tightened; otherwise, it would invalidate your warranty.
Note: Before connecting the DC power cord, please check whether your local DC power source is stable.
7. M12 DC Power Cable Pin Assignment
The front panel of the Industrial Managed Switch provides one M12 DC power 5-pin male connector for DC power input. Please use the power cable with the M12 DC power 5-pin female connector from the Industrial Managed Switch package for DC power input. The M12 DC power cable pin assignment is shown below:
[Diagram: Circular M12 5-pin connector with pins labeled V1+, V1-, V2+, V2-. A table shows pin assignments and corresponding wire colors.]
M12 DC power cable pin assignment and wiring code | |
---|---|
V1 positive (+) pin | black cable |
V1 negative (-) pin | brown cable |
V2 positive (+) pin | blue cable |
V2 negative (-) pin | white cable |
Note: Make sure you connect the correct power pin to your DC power source.
- The wire gauge for the power cable should be in the range of 12 ~ 24 AWG.
- The DC power input range is 9 ~ 48V DC.
Note: There are two methods to install the Industrial Managed Switch: DIN-rail mounting and wall-mount plate mounting. For more detailed information, please refer to Chapter 2.3 of the user's manual.
8. Requirements
Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
Workstations are installed with Ethernet NIC (Network Interface Card).
Ethernet Port Connection
- Network cables: Use standard network (UTP) cables with RJ45 connectors.
- The above PC is installed with Web browser.
Note: It is recommended to use Google Chrome or above to access the Industrial Managed Switch. If the Web interface of the Industrial Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.
9. Starting Web Management
The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
[Diagram: Network diagram showing a Managed Switch with IP address 192.168.0.100 connected via RJ45/UTP Cable to a PC/Workstation with Web Browser with IP address 192.168.0.x]
Logging in to the Industrial Managed Switch
- Use Google Chrome or above Web browser and enter IP address http://192.168.0.100 (default IP address) to access the Web interface.
Note: The following console screen is based on the firmware version before May of 2025.
Default Username: admin
Default Password: admin
[Image: Login screen dialog box for connecting to 192.168.0.100, with fields for User name and Password, and buttons for OK and Cancel.]
Note: The following web screen is based on the firmware version of May of 2025 or after.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: sw + the last 6 characters of the MAC ID in lowercase
[Image: Authentication required dialog box for connecting to 192.168.0.100, with fields for Username and Password, and buttons for Log in and Cancel.]
Change Password
Password | New Password | |
Retype Password | show password | |
[Button: Apply] [Button: Reset] |
The password must contain 8-31 characters, including upper case, lower case, numerals and other symbols. Please note spaces (blanks) are not accepted.
[Image: PLANET Industrial Managed Switch web interface showing status and a menu on the left.]
The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides.
[Image: Detailed list of switch menu options including System, SNMP, Port Management, VLANs, etc.]
Note: If you are not familiar with Switch functions or the related parameter, press "Help icon" anytime on the Web page to get the help description.
Now, you can use the Web management interface to continue the Switch management. Please refer to the user's manual for more details.
10. Saving Configuration via Web
To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot.
Note: The following console screen is based on the firmware version before May of 2025.
- Click System, Save Startup Config.
[Image: Screenshot of the switch menu with 'System' expanded and 'Save Startup Config' highlighted.]
Save Running Configuration to startup-config
[Button: Save Configuration]
Note: The following web screen is based on the firmware version of May of 2025 or after.
[Image: Screenshot of the switch menu bar with a 'Save Configuration' icon highlighted.]
Save Running Configuration to startup-config
Please note: The generation of the configuration file may be time consuming, depending on the amount of non-default configuration.
[Button: Save Configuration]
[Image: Screenshot of the switch maintenance menu with 'Save Startup Config' highlighted.]
11. Recovering Back to Default Configuration
IP address has been changed or admin password has been forgotten
Follow all the recovering back to default configuration steps as shown in the example.
- Power off the Industrial Managed Switch and remove all the existing connections.
- Use the straight RJ45 cable to connect to port 1 and port 2 in the loop topology as shown below:
[Image: PLANET switch with an RJ45 cable connected between port 1 and port 2.]
12. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource and User's Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQ: https://www.planet.com.tw/en/support/faq
Switch support team mail address: support@planet.com.tw
IGS-5227-6T/IGS-5227-6MT-X User's Manual: https://www.planet.com.tw/en/support/downloads?method=category&c1=industrial-ethernet&p=&type=3
(Please select your switch model name from the drop-down menu of Product Models.)
Copyright © PLANET Technology Corp. 2025
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.